Wall mount SYS1449-Wxx series 15W~20W Country of Origin : China Operating Temperature : 0~40 C Dimension : 72.5 x 34 x 45 mm Efficiency level (ErP) : Approvals / Marks : Features: Wall-mount power supply, single output. PSU housing ready for use in country : Overload, over voltage & short protection. USA (type W2) Europe (type W2E) For I.T.E. use only + RoHS conform. Australia (type W2A) China (type W2C) Wide range Input (90 ~ 264) VAC / (47 ~ 63) Hz. UK (type W3U) Specification: Voltage Min. Max. Total OVP Max. Ripple & Connector OCP Eff. Model DC Load Load regul. max Power Noise UL approval A % V A A % V W mV p-p mm SYS1449-1505-Wxx 5 0 3 5 3.4~7.0 9 15 >76 200 2.1x5.5x11 ErP V. SYS1449-1505-Wxx 5 0 3 5 3.4~7.0 9 15 >76 200 0.7x2.35x11-L SYS1449-2005-Wxx 5 0 4 5 4.4~8.0 9 20 >78 200 2.1x5.5x11 OEP Production This model is certified for upon models only. Uout=5V / Pout=15W or 20W Possible to order with Wxx = W2E - Europe W2 - USA,Canada,Japan W3U - UK W2A - Australia W2C - China Wxx Turn on delay 5000 ms max AC low line input output full load Hold up time 8ms min AC nominal input output full load (> half cycle) Efficiency (Normal) Minimum average efficiency in active mode 1.2 dv max At AC nominal input loading from 50% load to max load or peak load. Transient response (dv, OUTPUT tmax) 12ms t max Dynamic rise time 10uS max , duty 40mS max , Dynamic load step is slew rate of 0.5A/uS Overshoot / Undershoot more information will be provide on request ( V , T) Burn in test Full load 2 Hours Voltage (90 ~ 264)VAC Frequency (47 ~ 63) Hz Current 0.5A rms AC low line input and DC output full load INPUT Inrush Surge Current (cold start) 60A max At power supply cold start, ambient temperature 25 230Vac nominal AC input. Leakage current 0.25 mA Max. Power consumption <0.3W rms max. At AC nominal input output min load Over Current / The power supply will self-protect any output to ground, And auto recovery when abnormal circuit faults remove. Short protection An output short circuit is defined as any output impedance of less than 0.1 ohms. Short current and over current can not exceed (OCP) 8A max after 1 min. at nominal line input. Over Voltage (OVP) The power supply will not be auto recovered when faults remove >>Voltage limit<< PROTECTION Input protection 1A Fuse - The power supply shall be protected against power line surges and any abnormal condition. No load protection The power supply is provided with no load operation to prevent the power supply and system from damage. Protection class II. - - Dielectric Strength (Hi-pot) Primary to Secondary: 3000VAC / 10mA / 60s M.T.B.F 50K hours full rated load operation at 40 , according to the MIL-HDBK-217F. Cable length and type 1500mm (5feet) round cable, 1185 18*1C+SHIELD or depends on customer requirements OTHERS PLD (power line disturbance ) LINE POWER SURGE LINE VOLTAGE SAG more information will be provide on request Cooling method By natural air Housing material PC or PPO Temperature coefficient: < 0.5% / C Temperature Operating: (0 ~ 40)C / Storage: (-20 ~ 85)C ENVIRONMENT Humidity Operating: 8% ~ 90% RH / Storage: 5% ~ 95% RH non condensing SAFETY CE TUV/GS CB FCC cULus PSE BSMI EMC Meet EN55022 class B, Fcc part 15 Sub part B class B. EN 60950-1:2006+A11 LVD2006/95/EC IEC 60950-1:2005 WEIGHT 1pc N.W.: 139g / pc G.W.: 155g / pc 0.38(L) x 0.44(W) x 0.23(H) m PACKING Box 80 pcs / 1box N.W.: 11.2kg/box G.W.: 13.4 kg/box www.sunny-euro.com Wall mount SYS1449-Wxx series 15W~20W Mechanical case specification: Mechanical specification (country housing): Australia type (W2A) Europe type (W2E) US / Japan type (W2) UK type (W3U) Cable specification: 1185 18*1C+shield / 5FT (1500mm) www.sunny-euro.com