CSW65 Series Specifications Model CSW65 Input Input Voltage range Vac 90 - 305 Input Frequency Hz 47 - 63 Input Current (115/230VAC) A 2 / 1 Inrush Current at 230Vac (Cold Start) A <65 (25C ambient) Harmonic Compliance - Meets IEC61000-3-2 Class A No Load Power Consumption W <0.150 Hold Up Time (typ) at 115Vac Input ms 10 Efficiency - See model selector table Conducted & Radiated EMI - EN55032-B conducted and radiated, FCC Part 15 Class B Immunity - EN55024 Safety Agency Certifications - UL/CSA/IEC/EN62368-1, 60950-1, UL1310 Class 2 (24Vout only), CE Mark Output Output Voltage Accuracy % 1 Output Voltage Adjustment - None Switching Frequency (Full Load) kHz 65 Output Regulation % 5-24V: 3, 28-54V: 2 Ripple & Noise (20MHz BW) - See Model Selector Table Minimum Load - No minimum load required Overcurrent Protection % 105 - 160 (Auto-Recovery) Overvoltage Protection - See Model Selector Table (Cycle AC to reset) Parallel Operation - Not possible Series Operation - Possible, contact Technical Support Environmental Operating Temperature C -10 to +70 derate linearly to 50% load from 50 to 70 (Note 2) Storage Temperature C -20 to +85 Humidity (non condensing) %RH 5 - 95 Cooling - Convection Altitude m 5,000 Withstand Voltage (For 1 minute) Vac Input to Ground 1,500, Input to Output 3,000, Output to Ground 500Vdc Isolation Resistance M >20 at 25C & 70%RH, Output to Ground 500Vdc 2 Vibration (non-operating) m/s 23.52 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour) 2 Shock m/s <196.1 (20G) Other Weight (Typ) g U channel: 250, /A: 270, /D: 290 Size (LxWxH) mm U channel and /A: 120.7 x 63.5 x 38.1 /D: 120.7 x 63.5 x 47.2 Size (LxWxH) Inches U channel and /A: 4.75 x 2.5 x 1.5 /D: 4.75 x 2.5 x 1.86 Connectors Input: 3-Pole Terminal Block (9.5mm, 20A/300V) Output: 2-Pole Terminal Block (9.5mm, 20A/300V) Warranty yrs 3 Notes 1) See website for detailed specifications, test methods and installation manual 2) Derate linearly to 90% load from 0C to -10C 2 CSW65 Series