CPFE1000FI Series TDKLambda CPFE1000FI Series 720-1000W Conduction Cooled Power Supplies 720-1000W Conduction Cooled Power Supplies Features Features SSmaller size than CPFE1000F maller size than CPFE1000F Base plate cooled, no fan required Base plate cooled, no fan required PProtective coating option rotective coating option 2 I12C0 Interface Interface Key Market Segments & Applications Key Market Segments & Applications (e)) RoHS 41/4 Industrial COTS COMM LED Broadcast Specifications Speci cations Model AC Input AC Input VAC VAC 90 to 265VAC, 47-63Hz 90 to 265VAC, 47-63Hz Input CurrentInput Current (1) (1) A A 113.6 / 6.6 (Model dependant) 3.6 / 6.6 (Model dependant) Inrush Current (110 / 220VAC) Inrush Current (110 / 220VAC) A A 20 / 40 peak 20 / 40 peak Power Factor Power Factor - - 0.95 0.95 Efficiency (typical)E ciency (typical) (2) (2) % 79 to 86% (Model dependant) % 79 to 86% (Model dependant) Output Voltage Setpoint Accuracy Output Voltage Setpoint Accuracy - - 2% at 50% load 2% at 50% load Line Regulation Line Regulation mV mV 112V: 48mV, 28V: 56mV, 48V: 96mV 2V: 48mV, 28V: 56mV, 48V: 96mV Load Regulation Load Regulation mV mV 112V: 48mV, 28V: 56mV, 48V: 96mV 2V: 48mV, 28V: 56mV, 48V: 96mV Ripple and Noise (20MHz BW) (3) Ripple and Noise (20MHz BW) (3) - - 11% (2% below 0C) % (2% below 0C) Over Current Protection % 105 - 140% (Automatic recovery) Over Current Protection % 105 - 140% (Automatic recovery) Over Voltage Protection Over Voltage Protection - - 125 - 145% (Automatic recovery) 125 - 145% (Automatic recovery) Parallel Operation Parallel Operation - - Yes (Single wire) Yes (Single wire) Power On Signal (ENA) Power On Signal (ENA) - - Open collector (10mA sink current). Low (on) when output is present Open collector (10mA sink current). Low (on) when output is present Auxiliary Supply Auxiliary Supply - - 110 - 14V, 20mA 0 - 14V, 20mA Remote On/O (Opto isolated) - HHigh = On igh = On Remote On/Off (Opto isolated) - Temperature Coefficient Temperature Coe cient C C <0.02%/C <0.02%/C Overtemperature Overtemperature C C Shuts down between 90 - 115C (Auto recovery) Shuts down between 90 - 115C (Auto recovery) HHold Up Time (230VAC) old Up Time (230VAC) ms ms 220ms 25C and warmer 0ms 25C and warmer Leakage Current (at 230VAC, 50Hz) Leakage Current (at 230VAC, 50Hz) uA uA << 1.5mA 1.5mA Remote Sense - Yes, compensates up to 500mV cable drop Remote Sense - Yes, compensates up to 500mV cable drop II2C Interface C Interface - - Provides manufacturing location, date, serial number, part number, unit revision, output Provides manufacturing location, date, serial number, part number, unit revision, output voltage & current read back, base plate temperature, remote on/off, 10G, DC voltage & current read back, base plate temperature, remote on/o , IOG, DC ggood and over temperature warning ood and over temperature warning Operating Temperature Operating Temperature C C -40 to +70C ambient, (See reverse side for derating) (85C baseplate, maximum) -40 to +70C ambient, (See reverse side for derating) (85C baseplate, maximum) Storage Temperature C -40 to +100C Storage Temperature C -40 to +100C HHumidity umidity - - Operating: 20 - 90%RH, Non operating 10 - 95%RH (Pcb assembly protective coated) Operating: 20 - 90%RH, Non operating 10 - 95%RH (Pcb assembly protective coated) Cooling Cooling - - Conduction cooled Conduction cooled Withstand Voltage Withstand Voltage - - Input to Output 4242VDC, Input to Ground 2121VDC, Output to ground 500VDC Input to Output 4242VDC, Input to Ground 2121VDC, Output to ground 500VDC Vibration (non operating) Vibration (non operating) - - MIL-STD-810F, Method 514.5, Proc 1, Category 4, 10 MIL-STD-810F, Method 514.5, Proc 1, Category 4, 10 Shock - - MIL-STD-810F, Method 516.5, Proc. I, IV, VI MIL-STD-810F, Method 516.5, Proc. I, IV, VI Shock Safety Agency Approvals Safety Agency Approvals - - UL60950-1, CSA 22.2 No 60950-1, EN60950-1 (Ed 2), CE Mark UL60950-1, CSA 22.2 No 60950-1, EN60950-1 (Ed 2), CE Mark Line Dip Line Dip - - Complies with SEMI F47 (200VAC line only) Complies with SEMI F47 (200VAC line only) Conducted & Radiated EMI Conducted & Radiated EMI - - Conducted: EN55022/EN55011 Class B, Radiated: Class A Conducted: EN55022/EN55011 Class B, Radiated: Class A Immunity Immunity - - IEC61000-4-2 (Contact Level 2, Air discharge Lvl 3), -3 (Lvl 3), -4(Lvl 3), -5 (Lvl 3), IEC61000-4-2 (Contact Level 2, Air discharge Lvl 3), -3 (Lvl 3), -4(Lvl 3), -5 (Lvl 3), -6 (Lvl 3), -8 (Lvl 3), -11 (Class 3 ), -12 (Lvl 3), -14 (Class 3) -6 (Lvl 3), -8 (Lvl 3), -11 (Class 3 ), -12 (Lvl 3), -14 (Class 3) Weight (Typ) Weight (Typ) g 11240g (without cover) 240g (without cover) g Size (L x W x H) Size (L x W x H) mm mm 254 x 112 x 44mm (262mm including AC connector) 254 x 112 x 44mm (262mm including AC connector) Warranty Warranty yrs yrs 2 years 2 years (1) 110/220VAC (1) 110/220VAC (2) 2) 1100% loading required. 00% loading required. (3) 3) Warm up period of 30 minutes below -30C for ripple. Jeita RC-9131C Method, see instruction manual for test methods. Warm up period of 30 minutes below -30C for ripple. Jeita RC-9131C Method, see instruction manual for test methods.CPFE1000FI Series TDKLambda CPFE1000FI Series Model Selector Model Selector Output Adjust Maximum E ciency (%) Model Voltage (V) Range (V) Current (110/220VAC) CPFE1000FI-12 CPFE1000FI-12 112 2 99.6 - 14.4 .6 - 14.4 60 60 79 / 81 79 / 81 CPFE1000FI-28 CPFE1000FI-28 28 28 22.4 - 33.6 22.4 - 33.6 336 6 83 / 86 83 / 86 CPFE1000FI-48 CPFE1000FI-48 48 48 38.4 - 57.6 38.4 - 57.6 221 1 83 / 86 83 / 86 (4) Derating (Ambient Temperature)Derating (Ambient Temperature)(4) Input Output Power (W) Model Voltage 45C 50C 60C 70C CPFE1000FI-12 CPFE1000FI-12 85VAC to 170VAC 85VAC to 170VAC 720 720 720 720 720 720 720 720 170VAC to 265VAC 170VAC to 265VAC 720 720 720 720 720 720 720 720 CPFE1000FI-28 CPFE1000FI-28 885VAC to 170VAC 5VAC to 170VAC 1008 1008 980 980 952 952 896 896 170VAC to 265VAC 170VAC to 265VAC 1008 1008 1008 1008 11008 008 11008 008 CPFE1000FI-48 CPFE1000FI-48 885VAC to 170VAC 5VAC to 170VAC 1008 1008 1008 1008 11008 008 11008 008 170VAC to 265VAC 170VAC to 265VAC 1008 1008 1008 1008 11008 008 11008 008 OOutline Drawingsutline Drawings I MOUNTING HOLES M3 CLEARANCE 32 175 10.5 4 PLACES SIGNAL CONNECTORS 112 - out I OUTPUT BUS BARS NISxPOrnm STUD I *Volu I 254 44 ((4) Models mounted in the horizontal orientation. See instruction manual for alternative mounting positions and the 4) Models mounted in the horizontal orientation. See instruction manual for alternative mounting positions and the corresponding derating guidelines. corresponding derating guidelines. Options ForAdditional Information, please visit For Additional Information, please visit