FQB Series MIL-COTS 20A, 40Vdc Active EMC Filters The FQB filter modules have been designed to reduce differential and common mode conducted emissions from dc-dc switching converters. In addition, the series contains active suppression circuitry to block input voltage surges and transients. The FQB takes advantage of TDK technologies to simplify system level compliance to MIL-STD-461, MIL-STD-1275, RTCA/DO-160 and MIL-STD-704 per MIL-HDBK-704-8. The encapsulated rugged package design and a choice of baseplate options make the modules suitable for use in a wide variety of harsh and demanding environments, including MIL-COTS. Features Benefits Filtering for Compliance to MIL-STD-461(F,G) Simplifies the system EMC filter Input Spike and Surge Suppression per MIL-STD-1275(D,E), MIL-STD-704(A-F) and RTCA/DO-160G (Sec 16-18) Suitable for vehicle and airborne use High Differential and Common Mode Noise Attenuation Reduces system EMI -55 to 115C Temperature Range (M-Grade) For operation in harsh environments Standard (S-Grade) or Enhanced Screening (M-Grade) Options Reduces cost for COTS applications Quarter Brick Size Industry standard mounting and heatsinks Model Selector Operating Maximum Standard Enhanced Model Input Voltage Current Flanged Non-Flanged Screening Screening (Vdc) (A) Baseplate Baseplate (-S) (-M) FQB020ADC-007-S 8.5 to +40 20 X X FQB020ADC-N07-S 8.5 to +40 20 X X FQB020ADC-007-M 8.5 to +40 20 X X FQB020ADC-N07-M 8.5 to +40 20 X X Screening Options Operation S-Grade (Standard Screening) M-Grade (Enhanced Screening) Functional Test Room and Hot Test Cold, Room, and Hot Test Burn in Yes Extended, 96 hour Temperature Cycling No 10 Cycles Hi-Pot 2250VDC 2250VDC Visual Inspection Yes Yes 1 FQB SeriesSpecifications Model FQB Input/Output Input Voltage range Vdc Continuous: -40 to +40V. Transient: -50 to +210V (t < 1s. Varies with load, refer to input surge voltage suppression row). Input Voltage Spike Suppression V Typically 5V deviation for a 250V, 100s, 15mJ surge per MIL-STD-1275E (Vin 28V, 280W) Typically 5V deviation for a 600V, 10s, 50 source impedance per RTCA/DO-160G Input Voltage Surge Suppression V 47V maximum output with a 60V, 550ms surge per MIL-HDBK-704-8 (Po = 280W) (Vin 28V) 47V maximum output with an 80V, 80ms surge per MIL-HDBK-704-8 (Po = 280W) 47V maximum output with an 100V, 50ms surge per MIL-STD-1275(D,E) (Po = 280W) 47V maximum output with an 174V, 350ms surge per DEF-STAN 61-5 Part 6, (Po < 75W) Turn On/Off Voltage (Typical) Vdc Turn on: 8.5V, turn off: 8.3V Input Under & Over Voltage Protection - Module shuts down if an input or over voltage condition occurs. Auto recovery. Reverse Polarity Protection - Internal series MOSFET is held in an off state to avoid reverse current flow Input Current (Maximum) A 20A Overcurrent Protection - Limits the output current, with timed shutdown to allow module to cool. Auto restart. No Load Input Current (Typical at 28V Input) mA 3mA. 1.5mA if module is turned off using the remote on/off. DC Resistance (Typical) m Positive leg: 25m, negative leg: 5m Power Loss W Typically 12.5W at 20A Remote On/Off - Module is ON when Pin 2 is left open off when Pin 2 is connected to Pin 3 (-Vin) DC Good / Fault Signal - Open collector signal, low = Good Output Capacitance uF 3,000uF maximum. Contact factory for higher values. Differential Mode Attenuation at 300kHz dB 50dB (typical with a 50 source & load impedance) Common Mode Attenuation at 1MHz dB 30dB (typical with a 50 source & load impedance) Qualification Methods - Consistent with MIL-STD-883F and MIL-STD-202G (Tested to the most stringent listed) Radiated RE101 Navy Emissions RE102 10kHz to 18GHz Fixed Wing internal, >25m Nose to Tail Conducted CE101 Surface ships and submarines Compliance Testing (2) Emissions CE102 Basic Curve CS101 Curve 2, Imax=10A Conducted CS114 Curve 5 Susceptibility CS115 Basic Test Signal CS116 10kHz to 100MHz Safety Agency Certifications - IEC/UL/CSA/EN62368-1, 60950-1, CE Mark Environmental (1) Operating Baseplate Temperature (max) C Standard screening (-S): -40C to +115C, Enhanced screening (-M): -55C to +115C Storage Temperature C -65 to 125C Operating Humidity (non condensing) %RH MIL-STD 883 Method 1004.7 Cooling - Conduction, convection or forced air Withstand Voltage (For 1 minute) VAC Terminals to Case: 2250Vdc Vibration - MIL-STD-202G, Method 201A, Unpowered, sweep 1: 5 to 50 Hz at 0.5g, sweep 2: 50 to 500 Hz at 1.5g, three axis Shock - MIL-STD-202G, Method 213B, Table 213-1, Test Condition I, Unpowered, 50G half sine 6ms, three axis Other Weight (Typ) g 100g (Flanged version) Size (LxWxH) mm Flanged version: 60.6 x 55.9 x 12.7, Non-flanged version: 60.6 x 39 x 12.7 Size (LxWxH) Inches Flanged version: 2.39 x 2.2 x 0.5, Non-flanged version: 2.39 x 1.54 x 0.5 MTBF - Telcordia SR-332 issue 3 Hours 50C ambient, full load: 11,000,000 hours Warranty Years 3 Notes See website for detailed specifications, test methods and installation manual 1. See thermal performance section 2. Tested using TDK-Lambda evaluation kit containing FQB020ADC-007-S transient filter, combined with HQA2W120W280V-007-S and HQA2W120W050V-007-S power modules and a 200W resistive load. 2 FQB Series