GXE600 Series Single output 600W Programmable Medical and ITE Power Supplies Features Convection Cooled Up to 95% E cient RS-485 Read-Write Communication (Modbus RTU protocol) Constant Voltage & Constant Current Modes Monitoring & Programming Functions Digital or Analog Programming Seven Year Warranty Key Market Segments & Applications Speci cations Model GXE600-24 GXE600-48 (1) AC Input Voltage range VAC 85 - 265VAC (47 - 63Hz). Withstands 300VAC for 5s Inrush Current (100 / 200VAC) A 40 / 40A Power Factor (100 / 200VAC) - Meets EN61000-3-2 (0.99 / 0.95) Input Current (115/230VAC) (Typ) A 6.1 / 3.1A Nominal Output Voltage VDC 24V 48V Maximum Output Current A 25A 12.5A Output Voltage Range (Manual Adjust) VDC 19.2 - 28.8V 38.4 - 57.6V (2) Output Voltage Range (Via Programming) VDC 4.8 - 28.8V 9.6 - 57.6V (2) Current Limit Set Point (Via Programming) A 5 - 28.8A 2.5 - 14.4A Temperature Coe cient %/C <0.02%/C Regulation - See Model Selector (3) Overcurrent Protection - >28.8A >14.4A (3) Overvoltage Protection V 28.8 - 31.2V 57.6 - 62.4V Hold Up Time (Typ at 100% load) ms 20ms Leakage Current (max) mA <0.3mA Standby Voltage Vsb) - 4.8V - 5.2V 1A Remote Sense - Yes Remote On/O - Isolated opto-coupler. Unit o when current is owing through the opto diode Power Fail Signal - Signal is high when the output voltage drops due to AC loss or OCP, OVP, OTP AC Fail Signal - Signal goes high when the AC input is not present Parallel Operation - Yes, up to ve units (4) Operating Temperature (-40C start up) C Convection: -20 to +70C, derate linearly to 50% load from 50 to 70C Storage Temperature C -40 to +85C Operating Humidity (non condensing) %RH 20 - 90%RH Storage Humidity (non condensing) %RH 10 - 90%RH Cooling - Convection or forced air cooling Withstand Voltage VAC Input to Ground 2kVAC (1xMOPP), Input to Output 4kVAC (2xMOPP), Output to Ground 1.5kVAC (1xMOPP), Output to Signals 100VAC for 1 min. Isolation Resistance M >100M at 25C & 70%RH, Output to Ground 500VDC 2 Vibration (non operating) - 10 - 55Hz: 19.6m/s (sweep 1 min) X, Y, Z for 1 hour /HD version: Designed to meet MIL-STD-810G 514.7 Category 4, 10 2 Shock - < 196.1m/s /HD version: Designed to meet MIL-STD-810G 516.7 Procedure I, VI Safety Agency Certi cations - IEC/UL/CSA/EN60950-1, IEC/UL/CSA/EN62368-1, IEC/ES/CSA/EN60601-1, IEC/EN62477-1 (OVC III), CE Mark Line Dips - SEMI-F47 (200VAC input) Conducted & Radiated EMI - EN55011 / EN55032-B, FCC Class B, VCCI-B Immunity - IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2, IEC60601-1-2 Ed 4 Weight (Typ) g 1300 Size (WxHxD) mm 127 x 41 x 254mm MTBF - Telcordia SR-332 issue 3* Hours 511,677 hours Warranty Yrs Seven Years (1) 85Vac: 360W, 100 to <170Vac: 500W, 170V to 265Vac: 600W (Convection cooled). 600W when forced air is applied (see installation manual) (2) Using RS-485 communications or external 1-6V voltage source. See installation manual for details (3) Overcurrent & Overvoltage limits and recovery modes can be set using the RS-485 communications (4) See installation manual for full derating curves *24V output model, 25C ambient, full load, 230VAC input GXE600 Series Model Selector Output Max Output Load Reg Line Reg Ripple Noise E ciency (typ) % Model Voltage (V) Power (W) (mV) (mV) (mV) 115/230 VAC GXE600-24 24 600 144 96 150 92 / 95 GXE600-48 48 600 288 192 350 92 / 95 Monitoring and Programming Functions Function Digital (RS-485) Control Analog Control Output Voltage Monitor Read back No Output Current Monitor Read back No Output Voltage Programming Adjustable Adjustable, use a 1-6V external voltage source Output Current Programming Adjustable Adjustable, use a 1-6V external voltage source Over Voltage Protection Set Point Adjustable Fixed Over Voltage Recovery Auto-recovery or manual settings Cycle AC input or use the remote on/o Over Current Set Point Adjustable Fixed Over Current Recovery Auto recovery: Constant current, hiccup or foldback Constant current, auto-recovery Latching: Constant current or foldback Over Temperature Recovery Cycle AC input or use the remote on/o Cycle AC input or use the remote on/o Remote On/O Yes, enable or inhibit type Yes, enable or inhibit type o Internal Temperature Monitoring Yes, -20 to +100 C No Operating Run Time Log Records more than 20 years of data No Remaining Electrolytic Capacitor Life Indicates hours left No Alarm History OCP, OVP, OTP, remote on/o , system error No Slew Rate (Rise-time) Control Voltage and current No Communication Con guration ID, Baud Rate, Parity Not applicable Product Information Model , serial , lot , rmware version Not applicable Power Fail Signal Threshold Adjustable for either output voltage or current Fixed (voltage only) Outline Drawing Options For Additional Information, please visit