TF3000A60K 3000W Single Output 3000W Single Output TF3000 Family TF3000 Family Industrial Grade Industrial Grade FEATURES AND BENEFITS Remote Setting Multiple PSU via RS232, 3000W Fan-Cooled (Load & Temperature RS485 & IC Controlled) Industrial 2 Power OK Signal Programmable Output Current (0% ~ 105%) Remote ON/OFF, Remote Sense Function Forced Current Sharing at Parallel Operation Protection: OVP, OLP, OTP, Fan Failure Constant Current Limit 3 Year Warranty Selectable +5V/0.5A or +9V/0.3A Auxiliary RoHS Compliant Output Global Control via RS232 MODEL SELECTION Output Rated Current Output Ripple & Line Load Voltage 4 Model Number Efficiency 1 3 Volts Current Range Power Noise Regulation Regulation Tolerance TF3000A12K 12V 200A 0-200A 2400W 150mV pk-pk 1% 1% 2% 88% TF3000A15K 15V 160A 0-160A 2400W 150mV pk-pk 1% 1% 2% 89% TF3000A24K 24V 125A 0-125A 3000W 240mV pk-pk 1% 1% 2% 91% TF3000A K V A 0- A 3000W 0 mV pk-pk 1% 1% 2% 92% TF3000A48K 48V 62.5A 0-62.5A 3000W 480mV pk-pk 1% 1% 2% 92% 60V 50A 0-50A 3000W 600mV pk-pk 1% 1% 2% 93% Notes : 1. See CMD VS Output Curve. 4. Other output voltages available, consult factory. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted 5. Recovery after reset AC power ON or inhibit. pair-wire terminated with a 0.1uF & 47uF parallel capacitor. 6. All specifications are typical at 230Vac, full load, at 25C ambient unless noted. 3. Tolerance: includes setup time tolerance, line regulation and load regulation. INPUT OUTPUT Output Voltage See Model Selection Table on pg 1 Input Voltage and 100-240Vac, 10%, 47-63Hz, 1127-370Vdc 1 Frequency 3000W continuous (2400W for 12V, 15V 1 models) See model selection table for 115Vac: 19.7A (2000W output) Output Power Input Current specific voltage model ratings 230Vac: 14.5A (3000W output) Voltage Range 5.0% Typical adjustment by potentiometer (VR1) Inrush Current 33A/115VAC, 65A/230VAC Voltage Tolerance See Model Selection Table on pg 1 Efficiency See Model Selection Table Hold-Up Time 14ms/230VAC at full load Power Factor 0.95/230VAC, 0.98/115VAC at full load 800ms Turn On Time Leakage Current < 3.5mA/240VAC 100ms at full load Rise Time Ripple and Noise See Model Selection Table on pg 1 Notes : 1. De-rating may apply in low input voltage. Please check the de-rating curve for more details Line/Load Regulation See Model Selection Table on pg 1 Notes : 1. De-rating may apply in low input voltage. Please check the de-rating curve for more details CONNECTOR INFORMATION Input Connector Output Connector Signal Connector Term. 1) AC LINE Pinout: Term. 2) NEUTRAL + and - See Signal Connector Table on pg 3 Term. 3) GROUND Connector: JST PHDR-24VS or equivalent Mating Connector 10 wire lugs 1/4-20 Wire Lugs /terminal: Pins: JST SPHD-002T-P0.5 or equivalent TF3000 Family Datasheet v020 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 1 3000W Single Output 3000W Single Output TF3000 Family TF3000 Family Industrial Grade Industrial Grade EMI/EMC COMPLIANCE AUXILIARY SIGNALS Conducted Emissions Certified EN 55022 EN 61204-3 EN 61000-6-3 Selectable +5V/0.5A or +9V/0.3A auxiliary Auxiliary Power output Radiated Emissions Certified EN 55022 EN 61204-3 EN 61000-6-3 Remote ON / OFF Electro-Static Discharge By external switch Control (ESD) Immunity on Power EN55024/IEC61000-4-2 ports Open drain signal low when PSU turns on, Max. Power OK Signal Radiated RF EM Fields sink current: 20mA, Max. drain voltage: 40V EN55022/EN61000-4-3 Susceptibility Adjustment of output voltage is between Output Voltage Trim 0 ~ 105% of rated output Electrical Fast EN55024/IEC61000-4-4 Transients (EFT) /Bursts Adjustment of output current is between Output Current Trim 0 ~ 105% of rated output Surges, Line to Line EN55024/IEC61000-4-5 (Diff Mode) and Line to GND (CMN Mode) Please refer to Current Sharing with Remote 1 Parallel (Current Sharing) Sensing (Parallel Connection) Diagram Conducted Disturbances EN55022/IEC61000-4-6 induced by RF Fields Notes : 1. In parallel connection only one unit will operate if the total output load is less than 5% of the rated power. Rated Power frequency EN55024/IEC1000-4-8 magnetic fields Voltage Interruptions, PROTECTION EN55024/IECEN61000-4-11 Dips, Sags & Surges 120 7% of Vout, Latch Type (Recovery after Harmonic Current EN61000-3-2 Overvoltage Protection reset AC power ON or inhibit). (Refer to VCI vs. Emissions OVP Curve) Flicker Test EN61000-3-3 Short Circuit Protection Constant current, auto-recovery Notes : 1. The power supply is considered a component which will be installed into Overtemperature a final equipment. The final equipment must be re-confirmed that it still 855C measured on NTC. Auto recovery Protection meets EMC directives. Overload Protection 105% of rated power, constant current type SAFETY Safety Certifications 2 ISOLATION SPECIFICATIONS Input-Output: 3000Vac 1 Input-Ground: 1500Vac Isolation 1 Isolation Output-Ground: 500Vac RELIABILITY Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms/500VDC MTBF >112,000 hours per MIL-HDBK-217F Notes : 1. This test is done without enclosure: I/P-O/P 4242VDC. If with enclosure: I/P-O/P 2121VDC,I/P-FG:2121VDC, O/P-FG: 707VDC ENVIRONMENT Operating Temperature -25 ~ +60C (Refer to load de-rating curve) Temperature Derating See Derating Curve Vibration 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes Compliance to IEC 68-2-6, IEC 68-2-64 Dimensions 127 x 64 x 280mm 5.0 x 2.5 x 11.02 inch Cooling Load and temperature control fan Relative Humidity 20% to 90%, non-condensing Storage Temperature and Humidity -40 ~ +85C, 10 ~ 95% RH Weight & Packing 2.6kg 6pcs/carton, 16.6kg/1.86CUFT TF3000 Family Datasheet v0819 Copyright 2019 SL Power Electronics Corp. All rights reserved. TF3000 Family Datasheet v020 Copyright 20 20 SL Power Electronics Corp. All rights reserved. Page 2