PAQ SERIES DC/DC 1/8 Brick50-100W 2 Features Model naming method 1/4 brick industry standard size (36.88.557.9 PAQ 100 S 48 5 / PAQ Option mm) Blank: ON/OFF control negative logic, 3 OVP manual reset Compact/slim/high power density: 90.1W/inch P: ON/OFF control positive logic, OVP manual reset PAQ100S48-5 V: ON/OFF control negative logic, OVP automatic recovery B: With baseplate (PAQ100S48-* only) High efficiency: 90% (5V output type) ON/OFF control negative logic, OVP manual reset * Sample option combination: No use of heat sink PAQ100S48-5/BPV: With baseplate, ON/OFF control positive logic, Output voltage adjustable type OVP automatic recovery Nominal output voltage Internal capacitor: Functional polymer electrlytic Nominal intput voltage D: Dual output (output smoothing), ceramic S: Simple function Output power Series name Applications Conformity to RoHS Directive This means that, in conformity with EU Directive 2002/95/ EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. Product Line up PAQ-S Single Output 50W 100W Output Voltage Output Current Model Output Current Model 1.2V PAQ50S48-1R2 PAQ100S48-1R2 1.8V PAQ50S48-1R8 PAQ100S48-1R8 12A 25A 2.5V PAQ50S48-2R5 PAQ100S48-2R5 3.3V PAQ50S48-3R3 PAQ100S48-3R3 5V 10A PAQ50S48-5 20A PAQ100S48-5 PAQ65D Dual Output 65W Output Voltage Output Current / Model Output Current / Model Output Current / Model Output Current / Model 1.8V 17A 17A 2.5V 15A 17A PAQ65 PAQ65 PAQ65 PAQ65 D48-2518 D48-3318 D48-3325 D48-5033 3.3V 15A 15A 16A 5V 13A web191203 All specifications are subject to change without notice. B-225PAQ 50S48 PAQ50S48-* Specifications PAQ50S48 MODEL PAQ 5 0 S 4 8 -1R 2 PAQ 5 0 S 4 8 -1R 8 PAQ 5 0 S 4 8 -2 R 5 PAQ 5 0 S 4 8 - 3 R 3 PAQ 5 0 S 4 8 - 5 ITEMS/UNITS Voltage Range V DC36 - 76 Input Efficiency (typ) (*1) 78 83 85 88 90 Current (typ) (*1) A 0.39 0.56 0.75 0.96 1.18 Nominal Voltage VDC 1.2 1.8 2.5 3.3 5 Maximum Current A 12 10 Maximum Power W 14.4 21.6 30 39.6 50 Voltage Setting Accuracy (*1) 1 Output Maximum Line Regulation (*2) mV 10 Maximum Load Regulation (*3) mV 10 Temperature Coefficient Less than 0.02%/ Maximum Ripple & Noise (*8) mVp-p 100 Voltage Adjustable Range (*8) -20%, +10% 15% Over Current Protection (*4) 105% - 150% (Option availavle : Refer to option table) Over Voltage Protection (*5) 120% - 140% (Option availavle : Refer to option table) Remote Sensing (*6) Possible Function Remote ON/OFF Control Possible (Option availavle : Refer to option table) Parallel Operation (*6) - Series Operation (*6) Possible Operating Temperature (*7) Ta= -40 to +85 Storage Temperature -40 to +100 Operating Humidity RH 5 - 95 (No dewdrop) Storage Humidity RH 5 - 95 (No dewdrop) Environment At no operating, 10-55Hz (sweep for 1min.) Vibration Amplitude 0.825mm constant (maximum 49.0m/s) X, Y, Z 1 hour each Shock 196.1m/s Cooling (*7) Convection cooled / Forced air cooled Withstand Voltage Input-Output : 1.5kVDC for 1min Isolation PAQ Isolation Resistance More than 100M at 25 and 70%RH Input-Output...500VDC Standards Safety Standards Approved by UL60950-1, CSA 22.2 No.60950-1, EN60950-1 Weight (typ) g 50 Mechanical Size (W x H x D) mm 36.8 x 8.5 x 57.9 (Refer to outline drawing) (*1) At 48VDC, maximum output current, air velocity = 2m/s and Ta = +25. (*2) 36 - 76VDC, constant load. (*3) No load - full load, constant input voltage. (*4) Constant current limiting. (The unit automatically shutdown when left in OCP condition with the output voltage less than the LVP level.) Auto restart option available. (*5) Inverter shutdown method, manual reset. Auto restart option available. (*6) Refer to Instruction manual. (*7) Refer to derating curve and instruction manual. (*8) External components are needed for operation. (Refer to basic connection and Instruction manual.) Basic Connection Option Table Option OVP, OCP Remote ON/OFF control Shut down Standard (ON/OFF control reset or Negative manual reset) (Short : ON, Open : OFF) /V Auto restart Shut down /P (ON/OFF control reset or Positive manual reset) (Short : OFF, Open : ON) /PV Auto restart (*1) Use an external fuse (fast blow type) for each unit. (*2) Put output capacitors. C1: 1F ceramic capacitor. C2: 10F tantalum capacitor or electrolytic capacitor. (*3) Refer to instruction manual for further details. B-226 All specifications are subject to change without notice.