SPECIFICATION CONTROL DRAWING 10595 70 OHM, AWG 24, 19 STRANDS OF AWG 36, Date: 04-09-04 RADIO FREQUENCY, MULTIPLEX DATA BUS CHEMINAX H Revision: Page 1 of 2 THIS SPECIFICATION SHEET FORMS A PART OF THE LATEST ISSUE OF RAYCHEM SPECIFICATION 1200. Page 2 is for Internal use only. CONSTRUCTION DETAILS ELECTRICAL CHARACTERISTICS DIMENSIONS ARE NOMINAL VALUES IN INCHES UNLESS OTHERWISE CHARACTERISTIC IMPEDANCE 70 5 ohms, Method C at 1 MHz DESIGNATED. CAPACITANCE - MUTUAL 30 pF/ft. (maximum) CONDUCTORS ATTENUATION 1.0 dB/100 ft. (nominal) at 1 MHz AWG 24, 19 Strands of 1.4 dB/100 ft. (maximum) at 1 MHz .025 AWG 36, Silver-Coated High Strength Copper Alloy .047 .003 DIELECTRICS Radiation-Crosslinked ADDITIONAL REQUIREMENTS Modified ETFE Colors - Light Blue/White COMPONENT WIRE PRIOR TO CABLING (Test procedures per MIL-W-22759) CROSSLINK PROOF 300 3C for 1 hour, .625 inch mandrel, .375 lb., 2.5 kV dielectric test LOW TEMPERATURE - COLD BEND -65 2C for 4 hours, .500 inch mandrel, 1.00 lb., 2.5 kV dielectric test SHRINKAGE 200 3C for 1 hour, .125 inch SHIELD (maximum) in 12 inches .111 INSULATION RESISTANCE 5000 megohms for 1000 ft. (minimum) AWG 38, INSULATION (DIELECTRIC) Tin-Coated Copper TENSILE STRENGTH 5000 lbf/in (minimum) ELONGATION 50% (minimum) INSULATION FLAWS SPARK TEST 3000 volts (rms) IMPULSE TEST 8.0 kV (peak) FINISHED CABLE (Test procedures per NEMA WC27500) BLOCKING 200C for 6 hours LOW TEMPERATURE - JACKET COLD BEND -55 5C for 4 hours, 6.00 inch mandrel .127 Radiation-Crosslinked CROSSLINKED VERIFICATION 300 5C for 6 hours, 6.00 inch mandrel Modified ETFE (nominal) FLAMMABILITY 3 seconds (maximum) 3.0 inches .133 (Method B of Spec 1200) (maximum), no flaming of facial tissue (maximum) JACKET FLAWS SPARK TEST 1000 volts (rms) IMPULSE TEST 6.0 kV (peak) JACKET TENSILE STRENGTH 5000 lbf/in (minimum) ELONGATION 50% (minimum) SHIELD COVERAGE 90% (minimum) JACKET THICKNESS .008 inch (nominal) VOLTAGE WITHSTAND 1500 volts (rms) (DIELECTRIC) Outer jacket color will be white (designated by a-9 appended Replaces EPD5618 and 5671 to the part number, e.g. 10595-9) unless otherwise specified. The length of lay shall be .75 inch (minimum) to 1.25 inches (maximum) Designate outer jacket color with a dash number in accordance with MIL-STD-681. Other codes and suffixes may be added to the part number, as necessary, to capture any additional WEIGHT 13.4 lbs/1000 ft. (maximum) requirements imposed by the purchase order. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. THIS SPECIFICATION SHEET TAKES PRECEDENCE 501 Oakside Avenue OVER DOCUMENTS REFERENCED HEREIN. RRRRR Redwood City, California 94063-3800 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE 1-800-227-8816 Fax: 1-650-361-6297 Wire & Cable IN EFFECT ON DATE OF INVITATION FOR BID.