44B1221 SPECIFICATION CONTROL DRAWING Date Revision TITLE TWO CONDUCTOR CABLE, SHIELDED, JACKETED, GENERAL PURPOSE, 1000 VOLT 3-3-07 F This specification sheet forms a part of the latest issue of Raychem Specification 55A. JACKET - RADIATION-CROSSLINKED, SHIELD - TIN-COATED COPPER COMPONENT WIRES - 44A0211 MODIFIED ETFE CABLE CONSTRUCTION DETAILS JACKET THICKNESS OUTSIDE DIAMETER CONDUCTOR SHIELD MAXIMUM PART NUMBER (in.) (in.) SIZE SIZE WEIGHT 1/ (AWG) (AWG) (lbs/1000 ft.) MINIMUM NOMINAL NOMINAL MAXIMUM 44B1221-26-* 26 36 .006 .008 .117 .123 10.6 44B1221-24-* 24 36 .006 .008 .129 .136 13.1 44B1221-22-* 22 36 .006 .008 .145 .152 16.5 44B1221-20-* 20 36 .006 .008 .161 .169 21.0 44B1221-18-* 18 36 .006 .008 .183 .192 28.0 44B1221-16-* 16 36 .006 .008 .199 .209 33.5 44B1221-14-* 14 36 .007 .009 .235 .247 46.7 44B1221-12-* 12 36 .007 .009 .273 .287 64.7 CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C LIFE CYCLE: 200 3C for 168 hours Maximum continuous conductor temperature LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours VOLTAGE RATING: 1000 volts (rms) at sea level SHIELD COVERAGE: 85% (minimum) ACCELERATED AGING: 300 3C for 7 hours VOLTAGE WITHSTAND TEST (Post Environmental): BLOCKING: 150 3C for 6 hours 1000 volts (rms), 60 Hz, 1 minute DIELECTRIC WITHSTAND: 3000 volts (rms), 60 Hz, 1 minute FLAMMABILITY (Procedure 1): 3 seconds (maximum) PART NUMBER 3 in. (maximum) no flaming of facial tissue The * in the part numbers above shall be replaced by color code JACKET COLOR: White preferred designators with a slash separating the component wire colors and a JACKET ELONGATION AND TENSILE STRENGTH: dash separating the component wire colors from the jacket color. Elongation, 50% (minimum) Tensile Strength, 5000 lbf/in (minimum) 1/ Example: AWG 20, black and brown component wires white jacket: JACKET FLAWS: 44B1221-20-0/1-9 Spark Test, 1.0 kV (rms) Impulse Dielectric Test, 6.0 kV (peak) NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. R Wire & Cable DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 1 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2006-2007 Tyco Electronics Corporation. All rights reserved.X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Multi-Conductor Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 8916-GRY-100 8917-BLK-100 8918-GRN/YEL-100 8920-BRN-1000 8920-RED-1000 89907-LT-DEC/GRY-500 CR3909-000 CR3927- 000 01342.35T.01 01364.35T.01 CS2885-000 CS8782-000 CS9912-000 6200UE-NAT-U1000 CTC-0062-20-9/5-9 CTC-0062-22-9/5-9 6304FE-877-U500 6309UE-877-1000 6320UE-NAT-U1000 644833-000 6502FE 8771000 6504UE-877-U1000 CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9-9CS2405 CY0660-000 706/2R-BLACK-EACH 720451-000 730859-000 MCC-USB-4-250 752687-000 768146-000 773159-000 7934A-BLK-1000 8125-CHR-100 8164-CHR-1000 820457-000 8205-CHR-1000 8240-BLK-U1000 82723-NAT-1000 82907-NAT-500 83003-YEL-500 83005-WHT-500 83006-DK-GRN-100 83008-WHT-1000 83009-BLK-100