SCD 55LF0114 SPECIFICATION CONTROL DRAWING Date Revision Title WIRE, RADIATION-CROSSLINKED, MODIFIED ETFE-INSULATED, 10-16-18 E ULTRA LOW FLUORIDE, LIGHTWEIGHT, GENERAL PURPOSE, 600 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 55A. CONDUCTOR - SILVER-COATED HIGH-STRENGTH INSULATION - ULTRA LOW FLUORIDE, COPPER ALLOY RADIATION-CROSSLINKED, MODIFIED ETFE TABLE I. CONSTRUCTION DETAILS DIAMETER OF FINISHED WIRE STRANDED WIRE CONDUCTOR MAXIMUM PART NUMBER CONDUCTOR MAXIMUM SIZE STRANDING RESISTANCE DIAMETER 1/ (inch) WEIGHT (AWG) (number x AWG) AT 20C (inch) (lbs/1000 ft.) MINIMUM MAXIMUM (ohms/1000 ft.) 55LF0114-30-* 30 7 x 38 .011 .012 117.4 .024 .002 .66 55LF0114-28-* 28 7 x 36 .014 .015 74.4 .027 .002 .91 55LF0114-26-* 26 19 x 38 .018 .020 44.8 .032 .002 1.4 55LF0114-24-* 24 19 x 36 .023 .024 28.4 .037 .002 2.0 55LF0114-22-* 22 19 x 34 .029 .031 17.5 .043 .002 2.9 55LF0114-20-* 20 19 x 32 .037 .039 10.7 .050 .002 4.4 55LF0114-18-* 18 19 x 30 .046 .050 6.8 .060 .002 6.5 55LF0114-16-* 16 19 x 29 .052 .057 5.3 .068 .002 8.3 TABLE II. PERFORMANCE DETAILS BEND TESTING MANDREL DIAMETER WEIGHT (inch) ( 3%) (lb) ( 3%) PART NUMBER 1/ IMMERSION, IMMERSION, COLD COLD LIFE CYCLE, AND LIFE CYCLE, AND BEND BEND ACCELERATED AGING ACCELERATED AGING 55LF0114-30-* .250 .375 .125 .500 55LF0114-28-* .250 .375 .125 .500 55LF0114-26-* .375 .500 .125 .500 55LF0114-24-* .375 .500 .250 1.00 55LF0114-22-* .500 .750 .375 1.00 55LF0114-20-* .500 .750 .500 1.00 55LF0114-18-* .500 1.00 .500 1.00 55LF0114-16-* .750 1.00 .750 1.00 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. TE Connectivity also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681, EXCEPT LIGHT COLORS SHALL BE DESIGNATED WITH AN AFTER THE COLOR CODE (0L, 1L, 2L, etc.). OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. Raychem, TE Connectivity, and TE Connectivity (logo) are trademarks. Raychem Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL. Redwood City, CA 94063-3800 Page 1 of 2 Phone: 1-800-522-6752 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. 2007-2018 TE Connectivity Ltd. family of companies. All Rights Reserved. Page Revision SCD SPECIFICATION CONTROL DRAWING 55LF0114 2 of 2 E WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 200C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING (CROSSLINKING PROOF): 300 3C for 7 hours BLOCKING: 230 3C for 24 hours COLOR: Per MIL-STD-681, except light colors (xL) shall meet Munsell color limits for UV laser markable wire in SAE AS22759. White preferred. CONCENTRICITY: 70% (minimum) FLAMMABILITY: Procedure 1, 3 seconds (maximum), 3 inches (maximum) no flaming of facial tissue FLUORIDE EXTRACTION: 70 2C for 168 hours, 20 ppm (maximum) HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft. (minimum) IDENTIFICATION, COLOR STRIPING, AND BAND DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight IMMERSION: Diameter increase 5% (maximum) no cracking, no dielectric breakdown INSULATION ELONGATION AND TENSILE STRENGTH: Elongation, 75% (minimum) 2 Tensile Strength, 5000 lbf/in (minimum) INSULATION FLAWS: Spark Test, 5.7 kV (rms) at 3 kHz Impulse Dielectric Test, 8.0 kV (peak) INSULATION RESISTANCE: 5000 megohms for 1000 ft. (minimum) INSULATION THICKNESS: 0.005 in. (minimum) LIFE CYCLE: 230 3C for 500 hours LOW TEMPERATURE-COLD BEND: -65 3C for 4 hours SHRINKAGE: 230 3C for 6 hours, 0.125 in. (maximum) in 12 inches SMOKE TEST: 250 5C, no visible smoke SOLDERABILITY (Quality Conformance, AWG 30-20 only): Per MIL-STD-202, Method 208, except without steam aging SURFACE RESISTANCE: 500 meghoms-in. (minimum), both readings THERMAL SHOCK RESISTANCE: 200 3C, 0.060 in. (maximum) UV LASER MARKING (Test per SAE AS22759, Quality Conformance, AWG 30-20 only): 70% (minimum average) for white (9) and light (-xL) insulation colors only VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz WRAP TEST: 313 3C for 2 hours 1/ PART NUMBER: The in the part numbers in Tables I and II shall be replaced by a color code designator. Example: AWG 22, white: 55LF0114-22-9 AWG 22, light green: 55LF0114-22-5L AWG 22, white with a black stripe: 55LF0114-22-90 1/ See footer section on page 1