55PC0211 SPECIFICATION CONTROL DRAWING Date Revision TITLE WIRE, RADIATION-CROSSLINKED, MODIFIED, ETFE-INSULATED, 07-08-04 H GENERAL PURPOSE, LIGHT AIRFRAME This specification sheet forms a part of the latest issue of Raychem Specifiction 55PC. CONDUCTOR - TIN-COATED COPPER INSULATION - RADIATION-CROSSLINKED, MODIFIED ETFE CONSTRUCTION DETAILS FINISHED WIRE CONDUCTOR DIAMETER ( in.) DIAMETER WEIGHT MAXIMUM WIRE CONDUCTOR ( in.) ( lbs/1000 ft. ) RESISTANCE PART NUMBER SIZE STRANDING LOWER UPPER TARGET AT 20C 1/ SPEC UPPER SPEC (AWG) (number x AWG) SPEC LOWER SPEC TARGET TARGET UPPER SPEC VALUE (ohms/1000 ft.) LIMIT LIMIT VALUE LIMIT VALUE LIMIT LIMIT 55PC0211-26-* .0183 .0362 1.38 1.52 26 19 x 38 .0175 .0191 41.3 .0328 .0345 55PC0211-24-* 24 19 x 36 .0225 .0233 .0241 26.2 .0378 .0395 .0412 1.98 2.13 55PC0211-22-* .0293 2.90 3.06 22 19 x 34 .0285 .0301 16.2 .0438 .0455 .0472 55PC0211-20-* .0365 .0375 .0385 .0557 4.38 4.57 20 19 x 32 9.88 .0523 .0540 55PC0211-18-* 18 19 x 30 .0452 .0464 .0476 6.23 .0616 .0635 .0654 6.59 6.90 55PC0211-16-* .0527 .0730 8.37 8.70 16 19 x 29 .0514 .0538 4.81 .0690 .0710 55PC0211-14-* 14 19 x 27 .0644 .0659 .0674 3.06 .0838 .0860 .0882 12.88 13.33 55PC0211-12-* .0845 19.73 20.30 12 37 x 28 .0825 .0865 2.02 .1020 .1047 .1074 55PC0211-10-* .1050 .1070 .1090 .1328 31.12 32.13 10 37 x 26 1.26 .1252 .1290 55PC0211- 8-* 8 133 x 29 .158 .163 .169 .701 .188 .196 .203 56.8 59.9 55PC0211- 6-* .205 .251 89.7 94.7 6 133 x 27 .198 .212 .445 .233 .242 55PC0211- 4-* 4 133 x 25 .250 .260 .268 .280 .300 .311 .322 145. 154. 55PC0211- 2-* .330 227. 240. 2 665 x 30 .320 .340 .183 .370 .383 .397 55PC0211- 1-* .360 .370 .380 .438 278. 291. 1 817 x 30 .152 .410 .424 55PC0211- 0-* 0 1045 x 30 .395 .415 .425 .116 .449 .466 .483 343. 366. 55PC0211-00-* .462 .545 450. 481. 00 1330 x 30 .440 .475 .091 .505 .525 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C INSULATION ELONGATION AND TENSILE STRENGTH: SHRINKAGE: 230 3C for 1 hour, 0.125 in.(maximum) in 12 in. Maximum continuous conductor temperature Total Insulation, VOLTAGE WITHSTAND TEST (Post Environmental): VOLTAGE RATING: 600 volts (rms) at sea level Elongation, 50% (minimum) 2500 volts (rms) COLOR: White preferred Tensile Strength, 5000 lbf/in (minimum) PART NUMBER: CROSSLINK VERIFICATION: 300 3C for 1 hour INSULATION FLAWS: The in the part numbers above shall be replaced by IDENTIFICATION AND COLOR STRIPING DURABILITY: Spark Test, 3.0 kV (rms) color code designators. 125 cycles (250 strokes) (minimum), 500 g weight Impulse Dielectric Test, 8.0 kV (peak) 1/ Example: AWG 22, white: 55PC0211-22-9 INSULATION THICKNESS: .008 in. (nominal) total insulation AWG 22, white with black stripe: 55PC0211-22-90 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. RRRRR Wire & Cable 501 Oakside Avenue DIMENSIONS ARE IN INCHES AND, UNLESS OTHERWISE DESIGNATED, ARE NOMINAL Redwood City, CA 94063-3800 Page 1 of 1 Phone: 1-800-227-8816 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Fax: 1-650-361-6297 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.X-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Multi-Conductor Cables category: Click to view products by TE Connectivity manufacturer: Other Similar products are found below : 89504-002-1000 89705-008-500 6000FE-877-1000 CS2885-000 M27500-20SP2S23 6309UE-877-1000 M3905-BK005 6502FE 8771000 CW9530-000 CX6543-000 CXA-0066-20-4-9CS2973 CXA-0078-16-1-9CS2405 CXA-0078-22-4-9CS2405 CXA-0078-24-4-9CS2405 CXA-0140-16-6/9-9CS2405 CY0660-000 720451-000 752687-000 768146-000 773159-000 83318E-009-500 8348-060-500 83559-002- 1000 83653-002-5000 8404-060-500 8469 060100 858171-000 8628-060-500 868361-001 8730-060-1000 8737-060-U1000 8747-060-100 8747-060-1000 8769-060-1000 8775-060-500 8780-060-1000 8782-001-U1000 9159-060-500 9318-060-1000 939870-000 9423 060U500 9444 060U1000 9497 0001000 9520-060-1000 9524-060-1000 9546-060-500 9572-002-U500 9774-060-1000 A43962-000 1232A1-008- 1000