General Purpose Relays SCHRACK Power PCB Relay RT1 1 pole 12 / 16 A, 1 CO or 1 NO contact DC- or AC-coil Sensitive coil 400 mW 5 kV / 10 mm coil-contact, reinforced insulation Ambient temperature 85C (DC-coil) WG version: Product in accordance to IEC60335-1 RoHS compliant (Directive 2002/95/EC) as per product date code 0413 Applications F0144-B Boiler control, timers, garage door control, POS automation, interface modules Approvals V REG.-Nr. 6106,Z E214025, b 14385, B C0786, H 98.4118.01, Technical data of approved types on request Contact data Contact configuration 1 CO or 1 NO contact Contact set single contact Type of interruption micro disconnection Rated current 12 A 16 A Rated voltage / max.switching voltage AC 250/400 VAC Limiting continuous current UL: 20 A Maximum breaking capacity AC 3000 VA 4000 VA Limiting making capacity, max 4 s, df 10% 25 A 30 A Contact material AgNi 90/10, AgNi 90/10 gold plated 6 Mechanical endurance DC coil > 30 x 10 cycles 6 AC coil > 10 x 10 cycles -1 Rated frequency of operation with / without load 6 / 1200 min Contact ratings Type Load Cycles 3 RT314 16 A, 250 VAC, NO contact, 85C, DF 10%, UL508 50x10 -1 3 RT314 16 A, 250 VAC, NC contact, 70C, 30min 53x10 3 RT314 20 A, 250 VAC, NO contact, 85C, UL508 6x10 3 RT314 1000 W incandescent lamp, 250 VAC 1.2x10 3 RT314 10 A, 250 VAC, cos=0.6, CO contact, 70C 200x10 -1 6 RT314 5 A / 2 A, 250 VAC, cos=1, motor, NO contact, 10min , 70C 1.1x10 -1 6 RT314 0.26 A / 0.01 A, 230 VAC, cos=0.38, valve, NO contact, 25min 7.6x10 RT314 Pilot duty A300 (NO contact), B300 (CO/NC contact), UL508 RT314 1hp 240 VAC, 1/2hp 120 VAC, NO contact, UL508 RT314 AC15, 6 A, 250 VAC, NO and NC contact, 85C, EN60947-5-1 RT314 DC13, 2 A / 24 VDC, 0.2 A / 250 VDC, NO and NC contact, 85C, EN60947-5-1 Coil data Rated coil voltage range DC coil 5...110 VDC AC coil 24...230 VAC Coil power DC coil typ 400 mW AC coil typ 0.75 VA Operative range 2 Coil insulation system according UL1446 class F 1 Datasheet Rev. HC1 Dimensions are in mm unless Product specification processing information Schrack section. Issued 2008/03 otherwise specified and are according to IEC 61810-1. only to be used together www.tycoelectronics.com shown for reference purposes Product data, technical para- with the Definitions at Specifications subject to www.schrackrelays.com only. meters, test conditions and schrackrelays.com in the change.General Purpose Relays SCHRACK Power PCB Relay RT1 (Continued) Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 005 5 3.5 0.5 62+10% 403 006 6 4.2 0.6 90+10% 400 009 9 6.3 0.9 200+10% 400 012 12 8.4 1.2 360+10% 400 024 24 16.8 2.4 1440+10% 400 048 48 33.6 4.8 5520+10% 417 060 60 42.0 6.0 8570+12% 420 110 110 77.0 11.0 28800+12% 420 All figures are given for coil without preenergization, at ambient temperature +23C Other coil voltages on request Coil versions, AC-coil 50Hz Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power 50 Hz 50 Hz 50 Hz VAC VAC VAC Ohm VA 524 24 18.0 3.6 350+10% 0.76 615 115 86.3 17.3 8100+15% 0.76 620 120 90.0 18.0 8800+15% 0.75 700 200 150.0 30.0 24350+15% 0.76 730 230 172.5 34.5 32500+15% 0.74 All figures are given for coil without preenergization, at ambient temperature +23C Insulation Dielectric strength coil-contact circuit 5000 Vrms open contact circuit 1000 Vrms Clearance / creepage coil-contact circuit W 10 / 10 mm Material group of insulation parts W IIIa Tracking index of relay base PTI 250 V Insulation to IEC 60664-1 Type of insulation coil-contact circuit reinforced open contact circuit functional Rated insulation voltage 250 V Pollution degree 12 A version 3 3 16 A version 3 2 Rated voltage system 240 V 400 V Overvoltage category III Other data RoHS - Directive 2002/95/EC compliant as per product date code 0413 Flammability class according to UL94 V-0 For WG version: GWFI to IEC 60335-1 (IEC 60695-2-12) > 850 C GWIT to IEC 60335-1 (IEC 60695-2-13) > 755 C Ambient temperature range DC coil -40...+85C AC coil -40...+70C Operate- / release time DC coil typ 7 / 3 ms Bounce time DC coil, NO / NC contact typ 1 / 3 ms Vibration resistance (function), NO / NC contact 20 / 5 g, 30 ... 500 Hz Shock resistance (destruction) 100 g Category of protection RTII - flux proof, RTIII - wash tight Mounting pcb or on socket Mounting position any Mounting distance DC / AC coils 0 / 2.5 mm Resistance to soldering heat flux-proof version 270C / 10 s wash-tight version 260C / 5 s Relay weight 14 g Packaging unit 20 / 500 pcs Accessories For details see datasheet Accessories Power Relay RT 2 Datasheet Rev. HC1 Dimensions are in mm unless Product specification processing information Schrack section. Issued 2008/03 otherwise specified and are according to IEC 61810-1. only to be used together www.tycoelectronics.com shown for reference purposes Product data, technical para- with the Definitions at Specifications subject to www.schrackrelays.com only. meters, test conditions and schrackrelays.com in the change.