Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Highest Performance RFI Filters for Switching Power Supplies
Q Series
Q8
UL Recognized
CSA Certied
VDE Approved
Q1
Q3
Q Series Specications
Specically developed for switching power Maximum leakage current each Line to Ground:
supplies
3 & 20A VQ Models EQ Models
@120 VAC 60 Hz: .73 mA .22 mA
High attenuation for common and differential
@250 VAC 50 Hz: 1.27 mA .38 mA
mode interference
6A
Effective from 10kHz to 30MHz
@120 VAC 60 Hz: .29 mA
Optimized for attenuation and size
@250 VAC 50 Hz: .51 mA
3 or 6A versions available with IEC inlet
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Ordering Information
Rated Current: 3 to 20A
6 E Q 8 M
Operating Ambient Temperature Range
(at rated current I ): -10C to +40C
Sux r
In an ambient temperature (T ) higher than +40C
a
M Metric inserts (style 8 only)
the maximum operating current (I ) is calculated as
o
Omit for standard or none
follows: I = I (85-Ta)/45
o r
Input / Output Style
Available Part Numbers
1 .250 [6.3] spade terminals
3EQ1 6EQ8M
3 Wire leads
3EQ3 20EQ1
8 IEC inlet* (line side)
3EQ8 3VQ1
Wire leads (load side)
3EQ8M 3VQ3
6EQ1 3VQ8
Q Series
6EQ3 3VQ8M
6EQ8 20VQ1
Leakage current designation
E Low leakage (<0.5 mA)
Accessories
V Standard
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Current Rating
3, 6 or 20A
*IEC 60320-1 C14 inlet mates with C13 connector
58
Dimensions are in inches and millimeters unless otherwise specied. Values in italics For email, phone or live chat, please go to
te.com/help
are metric equivalents. Dimensions are shown for reference purposes only.
corcom.com
Specications subject to change.RFI Power Line Filters
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Highest Performance RFI Filters for Switching Power Supplies (continued)
Q Series
Electrical Schematics
Q8, Q8M (3A)
Tapped insert
3A
Brown
LINE LOAD
Grn/Yel
D B
Blue
1
A
E
C
6, 20A
LINE LOAD
Q8, Q8M (6A)
Case Styles
Tapped insert
Q1
3, 20A Models
Grn/Yel
C
B
0.63
Ref
Blue Brown
16.0
.313
Ref
7.95
D B
C
D
E
E
A
6A Models
A
B
C
Case Dimensions
A B CD E
Part No.
Q3
3A Models
3VQ1, 3EQ1
Blue Blue
Blue
Grn/Yel
3VQ3, 3EQ3
Grn/Yel
B
Brown Brown
Brown
3VQ8/8M,
A
C
3EQ8/8M
D
6A Models
E
6EQ1
Blue
B
Brown 6EQ3
Grn/Yel
C
6EQ8/8M
20EQ1,
20VQ1
59
Dimensions are in inches and millimeters unless otherwise specied. Values in italics For email, phone or live chat, please go to
te.com/help
are metric equivalents. Dimensions are shown for reference purposes only.
corcom.com
Specications subject to change.