Three Phase Filters
Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Compact Low Current 3-phase WYE RFI Filters
AYO Series
UL Recognized
CSA Certied
VDE Approved
22
AYO Series Specications
For 3-phase, four wire, WYE applications Maximum leakage current each Line to Ground:
3, 6, 10A 20A
Filters each of the three lines plus neutral
@ 120 VAC 60 Hz: 2.0 mA 3.5 mA
Good for attenuation beginning at 100kHz
@ 250 VAC 50 Hz: 3.0 mA 5.5 mA
Space saving design
Hipot rating (one minute):
Low leakage current Line to Ground: 1500 VAC
Line to Line: 1450 VDC
Easy to connect terminals
Rated Voltage (max):
Phase to Phase: 440 VAC
Phase to Neutral / Ground: 250 VAC
Operating Frequency: 50/60 Hz
Ordering Information
Rated Current: 3 to 20A
10 AYO 1
Operating Ambient Temperature Range
(at rated current I ): -10C to +40C
r
Input / Output Style
In an ambient temperature (T ) higher than +40C
a
1 0.25 [6.3] spade terminals
the maximum operating current (I ) is calculated as
o
follows: I = I (85-Ta)/45
o r
AYO Series
Current Rating
Electrical Schematic
3, 6, 10 or 20A
LINE LOAD
Available Part Numbers
3AYO1 6AYO1
N
N
10AYO1 20AYO1
111
Dimensions are in inches and millimeters unless otherwise specied. Values in italics For email, phone or live chat, please go to
te.com/help
are metric equivalents. Dimensions are shown for reference purposes only.
corcom.com
Specications subject to change.Catalog: 1654001
Corcom Product Guide Issue Date: 06.2011
Compact Low Current 3-phase WYE RFI Filters (continued)
AYO Series
Case Style Case Dimensions
A
D A B C D E
Part No.
AYO Series
B
C
E
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
3AYO1 6AYO1 10AY01 20AYO1
db db db db
100 100 100 100
90 90 90 90
80 80 80 80
70 70 70 70
60 60 60 60
50 50 50 50
40 40 40 40
30 30 30 30
20 20 20 20
10 10 10 10
0 0 0 0
0.1 1 10 30 0.1 1 10 30 0.1 1 10 30 0.1 1 10 30
Frequency in MHz Frequency in MHz Frequency in MHz Frequency in MHz
Common Mode / Asymmetrical (L-G)
Dierential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground) Dierential Mode / Symmetrical (Line to Line)
112
Dimensions are in inches and millimeters unless otherwise specied. Values in italics For email, phone or live chat, please go to
te.com/help
are metric equivalents. Dimensions are shown for reference purposes only.
corcom.com
Specications subject to change.