82A6013
SPECIFICATION CONTROL DRAWING
TITLE
Date Revision
WIRE, RADIATION-CROSSLINKED, MODIFIED FLEXIBLE ETFE-INSULATED,
8-4-10 D
NORMAL WEIGHT, GENERAL PURPOSE, 600 VOLT
This specification sheet forms a part of the latest issue of Raychem Specification 80.
JACKET - RADIATION-CROSSLINKED,
CONDUCTOR - NICKEL-COATED COPPER
MODIFIED FLEXIBLE ETFE
COLOR - WHITE
BRAID - NOMEX BRAID TREATED
PRIMARY INSULATION - RADIATION-CROSSLINKED,
TO PREVENT FRAYING
MODIFIED FLEXIBLE ETFE
COLOR - WHITE
COLOR - LIGHT GREEN
TABLE I. CONSTRUCTION DETAILS
DIAMETER OF FINISHED WIRE
STRANDED
WIRE CONDUCTOR
MAXIMUM
PART NUMBER
MAXIMUM
CONDUCTOR
SIZE STRANDING
RESISTANCE DIAMETER
1/
(in.) WEIGHT
(AWG) (number x AWG)
AT 20C (in.)
(lbs/1000 ft.)
MINIMUM MAXIMUM (ohms/1000 ft.)
82A6013-8 8 665 x 36 .157 .173 .714 .245 .008 81.2
82A6013-6 6 1045 x 36 .192 .208 .490 .292 .010 123.
82A6013-4 4 1665 x 36 .265 .285 .326 .374 .010 196.
82A6013-2 2 1665 x 34 .325 .345 .204 .447 .016 291.
TABLE II. PERFORMANCE DETAILS
BEND TESTING
PART NUMBER MANDREL DIAMETER WEIGHT
1/ (inch) ( 3%) (lb) ( 3%)
CROSSLINKING PROOF TEST CROSSLINKING PROOF TEST
82A6013-8 3.00 4.00
82A6013-6 4.00 4.00
82A6013-4 5.00 4.00
82A6013-2 6.00 6.00
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART
NUMBER. AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
The TE logo, Tyco Electronics and Raychem are trademarks.
Raychem Wire & Cable
NOMEX is a registered trademark of E.I. du Pont de Nemours and Company
501 Oakside Avenue
Redwood City, CA 94063-3800
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
Page 1 of 2
Phone: 1-800-227-8816
Fax: 1-650-361-6297
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
2010 Tyco Electronics Corporation. All rights reserved.Revision SCD Number
Page 2 of 2 D
SPECIFICATION CONTROL DRAWING
82A6013
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
CONCENTRICITY: 70% (minimum)
CROSSLINKING PROOF TEST: 300 3C for 7 hours
INSULATION ELONGATION AND TENSILE STRENGTH:
Elongation, 125% (minimum)
Tensile Strength, 3000 lbf/in (minimum)
INSULATION FLAWS:
Primary Insulation,
Spark Test, 1.5 kV (rms) at 3 kHz
Impulse Dielectric Test, 6.0 kV (peak)
Finished Wire,
Spark Test, 3.0 kV (rms) at 3 kHz
Impulse Dielectric Test, 8.0 kV (peak)
INSULATION THICKNESS:
AWG 8-4: .008 in. (minimum) for primary insulation
.012 in. (minimum) for outer jacket
AWG 2: .010 in. (minimum) for primary insulation
.015 in. (minimum) for outer jacket
SECANT MODULUS: (Test per ASTM D 882)
4 2
4.0 x 10 lbf/in (maximum), 2% strain, 2 inch jaw separation, 0.2 inch/minute
SHRINKAGE: 200 3C for 6 hours, 0.25 in. (maximum) in 12 inches
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz
PRODUCT IDENTIFICATION: Braid shall be marked in a contrasting color at
12 inch (nominal) intervals as follows: 82A6013-AWG 06090
1/ See footer section on page 1