SPECIFICATION CONTROL DRAWING
Product Name Product Revision Pre-installed Wire AWG
B-015-20 E 20
B-015-22 E 22
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride.
2. INSULATION SLEEVE: Heat-shrinkable, transparent clear, radiation cross-linked modified polyolefin.
3. SOLDER PREFORM WITH FLUX:
SOLDER: TYPE Sn63 per ANSI J-STD-006.
FLUX: TYPE ROL1 per ANSI-J-STD-004.
4. MELTABLE SEALING RINGS: Thermally stabilized thermoplastic. Color: blue.
5. DIELECTRIC BARRIER: Cross-linked polyvinylidene fluoride. Color: yellow.
6. CONDUCTOR LEAD: Raychem 55A0111-AWG stranded tin plated copper wire. Color: white.
7. GROUND LEAD: Raychem 55A0111-AWG stranded tin plated copper. Color: blue.
See table above for AWG information.
APPLICATION
1. These controlled soldering devices are designed for termination of the tin or silver plated copper braid and primary conductor
of coaxial cables having insulation rated for at least 85C.
2. Temperature range: -55C to +125C.
3. For installation, see RPIP-500-02.
For best results, prepare
that cable as shown:
TITLE :
THERMOFIT
COAXIAL TERMINATION
DEVICES
300 Constitution Drive
LOW TEMPERATURE
Menlo Park, CA 94025, USA
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS.
DOCUMENT NO.: B-015-20, B-015-22
INCHES DIMENSIONS ARE BETWEEN BRACKETS.
TOLERANCES: ANGLES: N/A Raychem reserves the right to amend this DCR NUMBER: REPLACES:
0.00 N/A drawing at any time. Users should evaluate
D001313 N/A
0.0 N/A ROUGHNESS IN the suitability of the product for their
0 N/A MICRON application.
DRAWN BY: DATE: PROD. REV. DOC ISSUE: SCALE: SIZE: SHEET:
M. FORONDA 18-Dec.-00 SEE TABLE 1 None A 1 of 1
If this document is printed it becomes uncontrolled. Check for the latest revision.