Table 1: Specications Voltage Input 12 to 18 VDC THS7CHG InputConnectorSize 2.1 mm Battery Charger Input Polarity Center conductor ZZZ positive Instructions Automotive Adapter For use with 12 VDC, Input negativegroundsystems only Do not operate the THS7CHG Battery Charger with the automotive adapter while cranking the vehicle engine or troubleshooting the vehicle electrical system Charging Charge in a dry Information location, not to exceed 45 C. The THS7CHG Battery Charger will not overcharge the THS7BAT battery pack Afullydischargedbattery pack typically recharges in 2 hours. A partially discharged battery pack recharges in less time *P070930904* To maintain peak 070-9309-04 performance of NiCd batteries, it is recommended to fully discharge them before Using the Battery Charger recharging The THS7CHG is for use with the THS7BAT Charge Time 2 hours, typical (fully battery packs. discharged battery pack) 1. Insert the plug onthe adapter cable into the Safety Only charge THS7BAT jack on the battery charger. battery packs in the THS7CHG Battery 2. Connect theadaptertothe powersource. Charger 3. Insert the battery pack into the battery NiCd batteries must be charger. LED indicates state of the battery recycled or disposed of charge: properly Steady red - charging at full rate Cleaning Clean with a soft cloth Steady green -ready, trickle charging dampened with water or Flashing red - battery problem, replace a 75% isopropyl alcohol battery solution CAUTION. To avoid damage to the battery Replaceable Parts There are no charger or AC adapter, do not substitute user-replaceable parts another AC adapter in place of the one insidetheTHS7CHG provided or use the AC adapter to power Battery Charger another instrument.Table 2: Accessories Equipment Recycling. This IEC 61000-4-6:2003. Conducted RF product complies with the immunity Power supply external Order Tektronix European Unions requirements IEC 61000-4-11:2004. Voltage dips and AC-DC 18 W, 100-220 VAC part number according to Directive 2002/96/EC interruptions immunity 47-63HZinput,12VDC1.5A 119-7285-XX on waste electrical and electronic output (Standard) equipment (WEEE). For more EN 61000-3-2:2006. AC power line harmonic information about recycling North America, Power Cord Order Tektronix emissions options, check the Support/Service (Standard A0) part number section of the Tektronix Web site 161-0066-00 EN 61000-3-3:1995. Voltage changes, (www.tektronix.com). uctuations, and icker Universal Euro, Power Cord Order Tektronix (Option A1) part number Battery Recycling. This product may be European Contact. 161-0066-09 accompanied by a Nickel Cadmium (NiCd) TektronixUK,Ltd. China, Power Cord (Option Order Tektronix or lithium ion (Li-ion) rechargeable battery, WesternPeninsula A10) part number which must be recycled or disposed of properly. Western Road 161-0304-00 Please properly dispose of or recycle the battery Bracknell,RG121RF accordingto local government regulations. U.K., Power Cord (Option A2) Order Tektronix UnitedKingdom part number Compliance Information 161-0066-10 Australia/New ZealandDeclarationofConformity This section lists the EMC (electromagnetic Australia,PowerCord(Option Order Tektronix EMC. Complies with the EMC provision of compliance),safety,andenvironmentalstandards A3) part number the Radiocommunications Actper the following with which the instrument complies. 161-0066-13 standard, in accordance with ACMA: Japan, Power Cord (Option Order Tektronix ECDeclarationofConformityEMC. Meetsintent CISPR 11:2003. Radiated and Conducted A6) part number of Directive 2004/108/EC for Electromagnetic Emissions,Group1,ClassA, inaccordance 161-0298-00 Compatibility. Compliance was demonstrated with EN 61326- 1:2006. Automotive Adapter (5A, Order Tektronix to the following specications as listed in the 250 V fuse included) part number Ofcial JournaloftheEuropeanCommunities: Warranty Information 174-1734-01 EN 61326-1 2006. EMC requirements for For warranty information, go to Battery Pack (Not included Order electrical equipment for measurement, control, www.tektronix.com service, and then use with the THS7CHG Battery THS7BAT 12 and laboratory use. the provided links to search for your products Charger) 1 This product is intended for use in nonresidential areas warranty. only. Useinresidential areas may cause electromagnetic Equipment Recycling. Production of this interference. equipment required the extraction and use Contacting Tektronix 2 Emissionswhichexceedthelevelsrequiredbythisstandard of natural resources. The equipment may mayoccurwhenthisequipmentisconnectedtoatestobject. Tektronix,Inc. contain substances that could be harmful to the 14200SWKarlBraunDrive CISPR 11:2003. Radiated and conducted environment or human health if improperly POBox 500 emissions, Group 1, Class A handled at the products end of life. In order Beaverton,OR97077 to avoid release of such substances into the IEC 61000-4-2:2001. Electrostatic USA discharge immunity environment and to reduce the use of natural For product information, sales, service, and resources, we encourage you to recycle this IEC 61000-4-3:2002. RF electromagnetic technical support: product inanappropriate systemthatwill ensure eld immunity that most of the materials are reused or recycled In NorthAmerica, call 1-800-833-9200. IEC 61000-4-4:2004. Electrical fast appropriately. transient / burst immunity Worldwide, visit www.tektronix.com tond contacts in your area. IEC 61000-4-5:2001. Power line surge immunity Copyright Tektronix,Inc. All rightsreserved. www.tektronix.com