Timers - Multifunctional E1ZM, E1Z1 ENYA series Up to 7 functions 7 time ranges Wide input voltage range 1 change over contact Width 17.5 mm Installation design Technical data 1. Functions 6. Output circuit The function has to be set before connecting the relay to the supply 1 potential free change over contact voltage. Rated voltage: 250V AC E ON delay Switching capacity: 2000VA (8A / 250V) R OFF delay Fusing: 8A fast acting 6 Ws Single shot leading edge with control input Mechanical life: 20 x 10 operations 5 Wa Single shot trailing edge with control input Electrical life: 2 x 10 operations Es ON delay with control input at 1000VA resistive load Wu Single shot leading edge voltage controlled Switching frequency: max. 6/min at 1000VA resistive load Bp Flasher pause first (in accordance with IEC 60947-5-1) Overvoltage category: III (in accordance with IEC 60664-1) Function sets of the distinct types are according to table ordering Rated surge voltage: 4kV information or printing on the unit. 7. Control input 2. Time ranges Input not potential free: terminals A1-B1 Time range Adjustment range Loadable: yes 1s 50ms 1s Max. line length: 10m 10s 500ms 10s Trigger level (sensitivity): automatic adaption to supply voltage 1min 3s 1min Min. control pulse length: DC 50ms / AC 100ms 10min 30s 10min 1h 3min 1h 8. Accuracy 10h 30min 10h Base accuracy: 1% of maximum scale value 100h 5h 100h Adjustment accuracy: <5% of maximum scale value Repetition accuracy: <0.5% or 5ms 3. Indicators Voltage influence: - Green LED U/t ON: indication of supply voltage Temperature influence: 0.01% / C Green LED U/t flashes: indication of time period Yellow LED R ON/OFF: indication of relay output 9. Ambient conditions Ambient temperature: -25 to +55C 4. Mechanical design Storage temperature: -25 to +70C Self-extinguishing plastic housing, IP rating IP40 Transport temperature: -25 to +70C Mounted on DIN-rail TS 35 according to EN 60715 Relative humidity: 15% to 85% Mounting position: any (in accordance with IEC 60721-3-3 class 3K3) Shockproof terminal connection according to VBG 4 (PZ1 required), Pollution degree: 2, if built-in 3 (in accordance with IEC 60664-1) IP rating IP20 Tightening torque: max. 1Nm 10. Weight Terminal capacity: Single packing: 72g 1 x 0.5 to 2.5mm with/without multicore cable end Package 10pcs: 670g per Package 1 x 4mm without multicore cable end 2 x 0.5 to 1.5mm with/without multicore cable end 2 x 2.5mm flexible without multicore cable end 5. Input circuit Supply voltage: terminals A1(+)-A2 E1Z... 12-240VAC/DC: 12 to 240V AC/DC Tolerance: 12V -10% to 240V +10% E1Z... 24-240VAC/DC: 24 to 240V AC/DC Tolerance: 24V-15% to 240V+10% Rated consumption: 4VA (1.5W) Rated frequency: AC 48 to 63Hz Duty cycle: 100% Reset time: 100ms Residual ripple for DC: 10% Drop-out voltage: >30% of minimum rated supply voltage Overvoltage category: III (in accordance with IEC 60664-1) Rated surge voltage: 4kV www.tele-online.comE1ZM, E1Z1 Functions ON delay with control input (Es) ON delay (E) The supply voltage U must be constantly applied to the device (green When the supply voltage U is applied, the set interval t begins (green LED U/t illuminated). When the control contact S is closed, the set LED U/t flashes). After the interval t has expired (green LED U/t interval t begins (green LED U/t flashes). After the interval t has expired illuminated) the output relay R switches into on-position (yellow LED (green LED U/t illuminated) the output relay R switches into on-position illuminated). This status remains until the supply voltage is interrupted. (yellow LED illuminated). This status remains until the control contact is If the supply voltage is interrupted before the expiry of the interval t, opened again. If the control contact is opened before the interval t has the interval already expired is erased and is restarted when the supply expired , the interval already expired is erased and is restarted with the voltage is next applied. next cycle. U U LED U/t LED U/t t <t R S t1 <t R OFF delay (R) The supply voltage U must be constantly applied to the device (green LED U/t illuminated). When the control contact S is closed, the output Single shot leading edge voltage controlled (Wu) relay R switches into on-position (yellow LED illuminated). If the control When the supply voltage U is applied, the output relay R switches contact is opened, the set interval t begins (green LED flashes). After into on-position (yellow LED illuminated) and the set interval t begins the interval t has expired (green LED U/t illuminated) the output relay (green LED U/t flashes). After the interval t has expired (green LED U/t switches into off-position (yellow LED not illuminated). If the control illuminated) the output relay switches into off-position (yellow LED not contact is closed again before the interval t has expired, the interval illuminated). This status remains until the supply voltage is interrupted. already expired is erased and is restarted. If the supply voltage is interrupted before the interval t has expired, the output relay switches into off-position. The interval already is erased and U is restarted when the supply voltage is next applied. LED U/t U <t S LED U/t t <t R t <t R Single shot leading edge with control input (Ws) Bp Cclico simtrico, comienzo por pausa The supply voltage U must be constantly applied to the device (green Al aplicar la tensin U, el rel R conecta en un tiempo t, desarrollando LED U/t illuminated). When the control contact S is closed, the output un ciclo simtrico con tiempos t iguales de conexin y desconexi. relay R switches into on-position (green LED U/t illuminated) and the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated) the output relay switches into off-position U (yellow LED not illuminated). During the interval, the control contact can LED U/t be operated any number of times. A further cycle can only be started when the cycle run has been completed. t t t t R U LED U/t S t t R Single shot trailling edge with control input (Wa) The supply voltage U must be constantly applied to the device (green LED U/t illuminated). Closing the control contact S has no influence on the condition of the output R. When the control contact is opened, the output relay switches into on-position (yellow LED illuminated) and the set interval t begins (green LED U/t flashes). After the interval t has expired (green LED U/t illuminated), the ouput relay switches into off-position (yellow LED not illuminated). During the interval, the control contact can be operated any number of times. A further cycle can only be started when the cycle run has been completed. U LED U/t S t t R www.tele-online.com