High Voltage Differential Probes HVD3605A, HVD3220, HVD3206A, HVD310xA Key Features The HVD3000A series high voltage differential probes provide high 1 kV , 2 kV, 6 kV CAT safety CMRR over a broad frequency range to simplify the measurement rated models challenges found in noisy, high common-mode power electronics Widest differential voltage environments. The probes design is easy-to-use and enables safe, ranges available precise high voltage floating measurements. Ex ceptional common-mode rejection ratio (CMRR) across a Exceptional Common-Mode Widest Application Coverage broad frequency range Rejection Ratio The HVD3000A series cover the fullest 1% gain accuracy The CMRR for the probes is range of applications, from 120/240V exceptional out to very high switch-mode power supplies through High offset capability at both frequencies, greatly improving 600 V class and 5 kV class electrical high and low attenuation measurement capability in the noisy, apparatus, Each model has the AC and DC coupling high common-mode environments best available gain accuracy, widest ProBus active probe interface found in power electronics. The high differential and offset voltage range, with automatic scaling CMRR combined with low probe noise and superior CMRR. AutoZ ero with auto and high offset capability provides 1500 Vdc CAT III Rating disconnect switch superior measurement capabilities The HVD3220 and HVD3206A support compared to other HV differential Wide oscilloscope compatibility 1500 V solar photovoltaic (PV) dc probes. measurements per the IEC/EN 61010- High Precision Measurements 031:2015 standard. They have a HVD3000A series probes provide 1% 1500 V CAT III and a 2000 V dc gain accuracy enabling precise voltage (DC+peakAC) CAT I rating. measurements. AutoZero capability Complete Probe Integration ensures further measurement precision The ProBus interface provides power by allowing small offset drifts to be and communication to the probe calibrated out of the measurement. eliminating the need for a separate This feature can be applied without power supply or batteries. Attenuation removing the HVD3000A leads from is automatically selected based on the device under test. oscilloscope gain range (V/div) setting. WIDE APPLICATION COVERAGE - 600 V TO 5 KV APPARATUS 600 V Class, 3-phase Electrical Apparatus The HVD310xA probes are available in a range of bandwidths from 25 to 120 MHz with standard 2 meter cable (6 meter cable model available). All probes have industry best CMRR for best noise-immunity, are guaranteed to 1% gain accuracy, and have the industrys widest differential voltage range in a 1 kV rated high voltage differential probe. Only 1 kV safety rated probe that serves the full 600 V class requirement 1500 V differential range with industrys best overshoot measurement capability (to 2000 V ) pk Industrys best offset capability (1500 V) when used with HDO Series oscilloscopes Bandwidth rating up to 120 MHz Sinusoidal AC DC Bus Drive / Inverter 6 meter cable model available Line Input Voltage Pulse-Width Modulated (PWM) Output (HVD3106A-6M) V V (Rated) V (with Overshoot)* pk-pk pk pk V or rms V dc Line- Line- Line- V Line-Line Line-Line Line-Line ac Models a vailable without accessories Neutral Neutral Neutral for a lower cost (HVD310xA-NOACC) 400 1131 653 566 566 327 849 491 480 1358 784 679 679 392 1019 588 600 1697 980 849 849 490 1274 735 690 1952 1127 976 976 563 1464 845 *Based on 50% overshoot condition 5 kV Class, 3-phase Electrical Apparatus The HVD3605A probe is safety-rated for 6000 V and 8485 V(DC + peak AC) for full coverage of 5 kV class apparatus. rms The probe has ample 100 MHz of bandwidth, is standard with a 6 meter cable, is guaranteed to 1% gain accuracy, has excellent CMRR, and has the industrys widest differential voltage range. Only probe that permits AC Line, DC Bus, and Drive/Inverter output voltage probing through 4160 V apparatus ratings Industrys best overshoot measurement capability (to 7600 V ) pk Industrys best offset capability (6000 V) when used with Sinusoidal AC DC Bus Drive / Inverter HDO Series oscilloscopes Line Input Voltage Pulse-Width Modulated (PWM) Output V V (Rated) V (with Overshoot)* pk-pk pk pk Standard 6 meter cable V or rms V dc Line- Line- Line- V Line-Line Line-Line Line-Line ac Neutral Neutral Neutral 2400 6788 3920 3395 3395 1960 4244 2450 3300 9334 5388 4666 4666 2694 5833 3368 4160 11766 6794 5884 5884 3397 7355 4246 *Based on 25% overshoot condition 2