I gather a 1.5 mm Allen wrench, a stranded wire with the specifications below, and a tool to strip the wire. I check that the wire and the parts of the plug have no default. I strip the end of the wire on 7 mm 1 mm. 2.6 mm maxi. (approximately 12 AWG). Specifications of the wire. 0.75 mm mini., 2.50 mm maxi.. Safety compliant with 1000 V CAT II / 21 39 20 mm (x13 mm overall thickness) 1000 V CAT III / 600 V CAT IV. Strands. 3.8(+0.1/-0.2) mm Jacket(s). 7 1 mm With the 1.5 mm Allen wrench I unscrew the Allen screw without removing it. I slip the stripped end of the wire through the gray plastic part and into the transverse hole of the metal part as shown below. Snap-on plastic part. Metal part. Gray plastic part. With the 1.5 mm Allen wrench I screw and tighten (2.3 N.m maxi. torque) the Allen screw on the end of the wire. I insert the metal part into the gray plastic part while I pull the wire. I insert the other side of the metal part into the snap-on plastic part. I push the gray plastic part towards the snap-on plastic part until they clip. As shown below. The 4 mm banana The 4 mm banana male Insulating gray tip on The design and the Transverse hole Allen screw connection complies the 4 mm banana of the metal part to attach the female connection material of the with the 4 mm banana complies with the male connection to lantern contact to slip the strands wire to the sockets of the prevent accidental spring meet the of the wire into. metal part. European 4 mm banana worldwide most plugs of the contact. need of low Union marking. famous manufacturers. resistance and worldwide most famous reliability. manufacturers. I check the gray plastic part is well locked in the snap-on plastic part. Fichier DataSheet TENMA 1076 . 24/10/2016. Indice A. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. 2016. Dimensions in millimeters. ACCESSIBLE. Able to be touched with a standard test finger or test pin. BASIC INSULATION. Insulation of HAZARDOUS LIVE parts which provides basic protection. CAT II. Measurement or overvoltage category II. For measurement per- formed on / equipment connected to the building wiring. CAT III. Measurement or overvoltage category III. For measurement performed on / equipment connected to part of a building wiring installation. CAT IV. Measurement or overvoltage category IV. For measurement performed on / equipment connected to the origin of the electrical supply to a building. According to EN / IEC 61010-031:2008. Up to 1000 V CAT II / 1000 V CAT III CLEARANCE. Shortest distance in air between two conductive parts. / 600 V CAT IV, reinforced insulation, up to 36 A (at +40 C) depending on the wire. CREEPAGE DISTANCE. Shortest distance along the surface of a solid According to EN / IEC 60529. IP2X (touchproof). insulating material between two conductive parts. These specifications come from the creepage distances, clearances, accessible parts, and solid CTI. Comparative Tracking Index of the insulating material in accordance insulation of the lead. And the considered specifications of the environment are : with IEC 60112. pollution degree, 1 or 2 DOUBLE INSULATION. Insulation comprising both BASIC INSULATION relative humidity, 80 % maximum for temperatures up to 31 C decreasing linearly to 50 % and SUPPLEMENTARY INSULATION. relative humidity at +40 C EN / IEC 60529:2001. The 2001 version of the European / international standard regarding the degrees of protection provided by enclosures. temperature range, +5 C to +40 C indoor use and EN / IEC 61010-1:2010. The latest version (in February 2012) of the European / international standard regarding the safety requirements for altitude, 2000 m maximum.+ electrical equipment for measurement, control, and laboratory use Part 1: General requirements. Version year 2010. EN / IEC 61010-031:2008. The latest version (in February 2012) of the European / international standard regarding the safety requirements for electrical equipment for measurement, control and laboratory use Part 031: Safety requirements for hand-held probe assemblies for electrical measure- ment and test. Version year 2008. LV. European Directive 2006/95/EC on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits. (Usually called the Low Voltage Directive.) -20 C mini., +80 C maxi. (please see above too). MAINS. Low-voltage electricity supply system to which the equipment concerned is designed to be connected for the purpose of powering the equipment. According to EN / IEC 61010-031:2008. The lead is compatible with the requirements of protec- MAINS CIRCUIT. Circuit which is intended to be directly connected to the tion against the spread of fire and resistance to heat by its basic insulation. MAINS for the purpose of powering the equipment. OVERVOLTAGE CATEGORY. Numeral defining a TRANSIENT OVER- European DirectiveLow Voltage Directiv 2014/35/EU. VOLTAGE condition. International / European standard EN / IEC 61010-031:2008. POLLUTION. Addition of foreign matter, solid, liquid or gaseous (ionized gases), that may produce a reduction of dielectric strength or surface International / European standard EN / IEC 60529. resistivity. European REACH regulation n1907 / 2006. POLLUTION DEGREE. Numeral indicating the level of POLLUTION that European DirectiveRoH 2011/65/EU. may be present in the environment. POLLUTION DEGREE 1. No POLLUTION or only dry, non-conductive RoH compliant, Pb 4 % in conductor, Pb 0.1 % in insulator, Hg 0.1 %, Cr VI 0.1 %, POLLUTION occurs, which has no influence. Cd 0.01 %, PBB 0.1 %, and PBDE 0.1 %. POLLUTION DEGREE 2. Only non-conductive POLLUTION occurs except that occasionally a temporary conductivity caused by condensation is REACH compliant, no substances from the candidate list of SVHC for authorisation at mass expected. concentrations greater than 0.1 %. REINFORCED INSULATION. Insulation which provides protection against electric shock not less than that provided by DOUBLE INSULATION. Conductors of the plugs : nickel-coated brass. RoH. European Directive 2011/65/EU on the restriction of the use of Insulators and lantern contact spring, please contact us. certain hazardous substances in electrical and electronic equipment. SOLID INSULATION. Insulating materials. Black Red SUPPLEMENTARY INSULATION. Independent insulation applied in addition to BASIC INSULATION in order to provide protection against electric shock in the event of a failure of BASIC INSULATION. Designed and manufactured in France. TRANSIENT OVERVOLTAGE. Short duration overvoltage of a few milliseconds or less, oscillatory or non-oscillatory, usually highly damped. Year of 1st placing on the market 1997. WORKING VOLTAGE. Highest r.m.s. value of the a.c. or d.c. voltage across any particular insulation which can occur when the equipment is supplied at rated voltage. One piece per bag (in one bag : 1 metal part including 1 Allen screw + 1 gray plastic part + 1 snap-on plastic part). Fichier DataSheet TENMA 1076 . 24/10/2016. Indice A. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. 2016. Dimensions in millimeters.