I gather the set of wrenches part number 2273, an insulating panel with the specifications below, and a tool to drill or punch out the panel as below. 11.0 0.5 mm 6.0 5.0 Panel material : (Cross-section.) insulating. Panel. Pitch circle diameter to 12.0(+0.1/-0)mm Maxi. drill the panel : Outline to punch out the thickness : 10 mm 12.0(+0.1/-0) mm panel. I drill or punch out the insulating panel as above with the tool. If the round nut is screwed on the socket then I remove it. I push 2.8 21.2 4.0 the socket into the hole of the insulating panel as shown below. With my hand I screw the round nut on the socket as shown below. Insulating panel. Round nut. Indentations 4 mm banana side of the round nut. of the socket. Front face Rear face of the panel. of the panel. I insert the thin wrench of part number 2273 into the 4 mm banana side of the socket as shown below. I insert the large wrench of part number 2273 into the indentations of the round nut as shown below. 14.2 14.5 M12 x 0.75 mm Thin wrench of part number 2273. Large wrench of part number 2273. The 4 mm banana Round nut to attach the socket Flat surface Terminal : 2 mm inner diameter hole I hold one wrench with my hand and the other wrench with my to the panel. The benefit of the female connection for anti- with 1.6 mm notch (complying with other hand. I rotate to screw and tighten the round nut (2.3 N.m round nut is that it does not European complies with the rotation both lead-tin and lead-free tin maxi. torque). Union 4 mm banana plugs need a lot of place to tighten. purpose (if soldering and 150 W maximum marking. of the worldwide needed). soldering iron). Now the socket is attached to the insulating panel. I achieve the most famous connection by soldering a stripped wire (iron solder with lead-tin manufacturers. or lead-free tin) on the terminal. Then the socket is ready to use. Fichier Datasheet TENMA 3275. 06/12/2016. Indice A. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. 2016. Dimensions in millimeters. ACCESSIBLE. Able to be touched with a standard test finger or test pin. BASIC INSULATION. Insulation of HAZARDOUS LIVE parts which provides basic protection. CAT II. Measurement or overvoltage category II. For measurement performed on / equipment connected to the building wiring. CAT III. Measurement or overvoltage category III. For measurement performed on / equipment connected to part of a building wiring installation. CAT IV. Measurement or overvoltage category IV. For measurement performed on / equipment connected to the origin of the electrical supply to a building. CLEARANCE. Shortest distance in air between two conductive parts. The design of the socket front face meets the requirements of EN / IEC 61010-031:2008 and the CREEPAGE DISTANCE. Shortest distance along the surface of a solid socket design is compatible with EN / IEC 61010-1:2010 for reinforced insulation at 1000 V CAT II / insulating material between two conductive parts. 1000 V CAT III / 600 V CAT IV and 25 A (at 40 C). CTI. Comparative Tracking Index of the insulating material in accordance with IEC 60112. These specifications come from the creepage distances, clearances, solid insulation, and CTI of the socket. And the considered building and implementation specifications are : insulating panel DOUBLE INSULATION. Insulation comprising both BASIC INSULATION and SUPPLEMENTARY INSULATION. pollution degree of the micro-environment, 1 or 2 relative humidity of the micro-environment, 80 % maximum for temperatures up to 31 C decreasing linearly to 50 % relative humidity at 40 C EN / IEC 60529. European / international standard regarding the degrees of protection provided by enclosures. temperature range of the micro-environment, +5 C to +40 C indoor use and altitude, 2000 m EN / IEC 61010-1. European / international standard regarding the safety maximum. IP2X (touch-protected) protection on the front face according to EN / IEC 60529. requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements. -20 C mini., +80 C maxi. (please see above too). EN / IEC 61010-031. European / international standard regarding the safety requirements for electrical equipment for measurement, control and The socket design is compatible with the EN / IEC 61010-031:2008 requirements of protection laboratory use Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test. against the spread of fire and resistance to heat by its basic insulation. The socket design is compatible with the EN / IEC 61010-1:2010 requirements of eliminating / reducing the sources ofLV. European Directive 2014/35/EU on the harmonization of the laws of Member States relating to electrical equipment designed for use within ignition within the equipment by its basic insulation. The socket isn t designed to comply with the certain voltage limits. (Usually called the Low Voltage Directive.) building of equipment containing or using flammable liquids and with circuits producing heat. MAINS. Low-voltage electricity supply system to which the equipment concerned is designed to be connected for the purpose of powering the equipment. European DirectiveLow Voltage Directiv 2014/35/EU. European DirectiveRoH 2011/65/EU. MAINS CIRCUIT. Circuit which is intended to be directly connected to the MAINS for the purpose of powering the equipment. European REACH regulation n1907 / 2006. International / European standard EN / IEC 61010-031:2008. OVERVOLTAGE CATEGORY. Numeral defining a TRANSIENT OVERVOLTAGE condition. International / European standard EN / IEC 61010-1:2010. POLLUTION. Addition of foreign matter, solid, liquid or gaseous (ionized International / European standard EN / IEC 60529. gases), that may produce a reduction of dielectric strength or surface resistivity. RoH compliant, Pb 4 % in conductor, Pb 0.1 % in insulator, Hg 0.1 %, Cr VI 0.1 %, POLLUTION DEGREE. Numeral indicating the level of POLLUTION that Cd 0.01 %, PBB 0.1 %, and PBDE 0.1 %. may be present in the environment. REACH compliant, no substances from the candidate list of SVHC for authorisation at mass POLLUTION DEGREE 1. No POLLUTION or only dry, non-conductive concentrations greater than 0.1 % POLLUTION occurs, which has no influence. POLLUTION DEGREE 2. Only non-conductive POLLUTION occurs except Conductors : nickel-coated brass or gold-coated brass. Insulator : please contact us, CTI < 175. that occasionally a temporary conductivity caused by condensation is expected. Black Red Yellow Green Blue REINFORCED INSULATION. Insulation which provides protection against electric shock not less than that provided by DOUBLE INSULATION. RoH. European Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 0.005 kg. SOLID INSULATION. Insulating materials. SUPPLEMENTARY INSULATION. Independent insulation applied in Designed and manufactured in France. addition to BASIC INSULATION in order to provide protection against electric shock in the event of a failure of BASIC INSULATION. Year of 1st placing on the market 1988. TRANSIENT OVERVOLTAGE. Short duration overvoltage of a few milliseconds or less, oscillatory or non-oscillatory, usually highly damped. One piece per bag (in one bag : 1 socket + 1 round nut). WORKING VOLTAGE. Highest r.m.s. value of the a.c. or d.c. voltage across any particular insulation which can occur when the equipment is supplied at rated voltage. Fichier Datasheet TENMA 3275. 06/12/2016. Indice A. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. 2016. Dimensions in millimeters.