TC4069UBP/UBF/UBFT TOSHIBA CMOS Digital Integrated Circuit Silicon Monolithic TC4069UBP, TC4069UBF, TC4069UBFT TC4069UB Hex Inverter TC4069UB contains six circuits of inverters. Since the internal TC4069UBP circuit is composed of a single stage inverter, this is suitable for the applications of CR oscillator circuits, crystal oscillator circuits and linear amplifiers in addition to its application as inverters. Because of one stage gate configuration, the propagation time has been reduced. Pin Assignment TC4069UBF I1 1 14 V DD O1 2 13 I6 12 O6 3 I2 O2 4 11 I5 I3 5 10 O5 O3 6 9 I4 V 7 8 O4 SS TC4069UBFT (top view) Circuit Diagram 1/6 TC4069UB V DD Weight DIP14-P-300-2.54 : 0.96 g (typ.) SOP14-P-300-1.27A : 0.18 g (typ.) TSSOP14-P-0044-0.65A : 0.06 g (typ.) INPUT OUTPUT V SS Start of commercial production 1978-04 1 2014-03-01 TC4069UBP/UBF/UBFT Absolute Maximum Ratings (Note) Characteristics Symbol Rating Unit DC supply voltage V V 0.5 to V + 20 V DD SS SS Input voltage V V 0.5 to V + 0.5 V IN SS DD Output voltage V V 0.5 to V + 0.5 V OUT SS DD DC input current I 10 mA IN Power dissipation P 300 (DIP)/180 (SOP) mW D Operating temperature range T 40 to 85 C opr Storage temperature range T 65 to 150 C stg Note: Exceeding any of the absolute maximum ratings, even briefly, lead to deterioration in IC performance or even destruction. Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum ratings and the operating ranges. Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook (Handling Precautions/Derating Concept and Methods) and individual reliability data (i.e. reliability test report and estimated failure rate, etc). Operating Ranges (V = 0 V) (Note) SS Characteristics Symbol Test Condition Min Typ. MaxUnit DC supply voltage V 3 18 V DD Input voltage V 0 V V IN DD Note: The operating ranges must be maintained to ensure the normal operation of the device. Unused inputs must be tied to either V or V . DD SS 2 2014-03-01