Highlights
5.8kW Single-Phase Metered PDU, 208/240V Outlets
Metered single phase 30A
(16 C13 & 2 C19), L6-30P, 12ft Cord, 2U Rack-Mount,
208/240V 2U horizontal
TAA
rackmount PDU
Two built-in meters report output
MODEL NUMBER: PDUMH30HV
current in amps for each load
bank
Attached 12ft / 3.6m cord with
NEMA L6-30P input plug
18 total outlets (16 C13, 2 C19)
Reversible housing, 2U 208/240V
rackmount metered PDU
TAA Compliant
Package Includes
2U rack PDU
Mounting brackets
Plug retention plates
User manual
Description
Tripp Lite single phase Metered PDU / Power Distribution Units offer real-time local reporting of load level in amps via built-in digital current metering. Enables
visual monitoring of PDU output current to preserve proper output balance and prevent circuit overloads as additional equipment is added. Offers reliable
rackmount multi-outlet power distribution from any protected UPS, generator or mains input power source. High quality design includes rugged all-metal
housing and secure rackmount installation with included mounting accessories.
Features
30A single phase 208/240V Metered Power Distribution Unit / PDU (Agency derated to 24A continuous)
Set of two lighted meters report PDU output current in amps for each 9 outlet load bank
Attached NEMA L6-30P 30A 208/240V input plug and 12ft / 3.6m cord
2U horizontal rackmount format installs in two rack spaces
18 output receptacles (16 C13, 2 C19)
Outlets are arranged in two 9 outlet load banks, each with separate 20A breaker and current metering
Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats
Mounting ears are reversible for front or rear facing rackmount installation
Cord retention brackets keep vital equipment plugs connected
Grounding lug
Compliant with the Federal Trade Agreements Act(TAA) for GSA Schedule purchases
Specifications
OVERVIEW
PDU Type Metered
1 / 3
OUTPUT
5.8kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per
Output Capacity Details
breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (16) C13; (2) C19
Output Nominal Voltage 200; 208; 240
Overload Protection Two 20A breakers protect 9 outlets each
INPUT
PDU Input Voltage 200; 208; 240
Recommended Electrical Service 30A 208/240V
Maximum Input Amps 30
Maximum Input Amps Details Agency de-rated to 24A continuous
PDU Plug Type NEMA L6-30P
Input Cord Length (ft.) 12
Input Cord Length (m) 3.65
Input Phase Single-Phase
USER INTERFACE, ALERTS & CONTROLS
Set of 2 digital meters continuously report output current for breakered load banks 1 & 2 (Bank 1: upper row of 9
Front Panel LCD Display
outlets / Bank 2: lower row of 9 outlets)
Switches n/a
PHYSICAL
Minimum Required Rack Depth
16
(inches)
Minimum Required Rack Depth (cm) 40.6
Shipping Dimensions (hwd / in.) 8 x 20.5 x 17
Shipping Dimensions (hwd / cm) 20.3 x 52.1 x 43.2
Shipping Weight (lbs.) 16.9
Shipping Weight (kg) 7.7
Unit Dimensions (hwd / in.) 3.5 x 17.5 x 12.5
Unit Dimensions (hwd / cm) 8.8 x 44.4 x 31.8
Unit Weight (lbs.) 13.7
Unit Weight (kg) 6.2
Material of Construction Metal
Form Factors Supported 2U rackmount; mounting accessories included