Dimming Control
High Efficiency (Up to 91%)
Active Power Factor Correction
Constant Current
Up to 305VAC Operation
Waterproof to IP67
Lightning Protection
Comprehensive Protection Circuitry
UL8750 & EN61347 Approvals
RoHS Compliant
Electrical Specifications
Input General
Efficiency See tables
Input Voltage 90-305VAC
Isolation 3kVAC input to output
Input Frequency 47-63 Hz 3kVAC input to ground
Input Current
1.5A @ 100VAC 0.5kVAC output to ground
0.75A @ 220VAC
250kHrs @110VAC, 2800mA model, 80%
MTBF (MIL-HDBK-217F)
Inrush Current 65A @ 220VAC/25C/Cold Start load, 25C
Power Factor See table
7.64L x 2.66W x 1.46H
Dimensions
Leakage Current 1mA @ 277VAC 2.20 lbs.
Net Weight
Environmental
Operating Temp. -35C to +65C,
Operating Humidity 10% to 100% RH, non-condensing
Storage Temperature
-40C to +85C
Output
Safety & EMC
Output Voltage See table
Start Up Delay 2 seconds maximum at 110VAC/220VAC
Safety Approvals
Line Regulation 1%
USA
UL8750 Approved
Load Regulation 3%
UL1012, UL935
Ripple & Noise
3% pk-pk, 20MHz bandwidth
Canada
Compliance to CAN/CSA-C22.2 No. 0
Overvoltage Latch mode; restart power to return to
CSA-C22.2 No. 107.1,
Protection normal operation
CSA-C22.2 No. 250.0
Short Circuit
No damage to unit; auto recovery when
Europe
EN61347-1, EN61347-2-13
Protection fault removed
EMI
EN55015 (Radiated & Conducted)
Overtemperature 110C maximum internal component
Harmonic Currents
EN61000-3-2 Class C
Protection temperature
Voltage Flicker
EN61000-3-3
ESD Immunity EN61000-4-2; 8kV air; 4kV contact
Radiated Immunity
EN61000-4-3
EFT/Burst
EN61000-4-4
Surge Immunity EN61000-4-5; (2kV line-line; 4kV line-gnd)
Conducted Immunity
EN61000-4-6
Note: All specifications typical at 25C unless noted.
Magnetic Field
EN61000-4-8
Dips / Interruptions
EN61000-4-11
Your Partners in Power...
Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749
Tel: (978)567-9600 | Fax: (978)567-9601
Specifications subject to change.
PIL120U-C-DT: 7/30/2014
Website: www.powerpartners-inc.com
LED PowerModels and Ratings Chart
Note 1: Measured at 220VAC input and full load.
Note 2: Additional suffix may be included to denote variations or modifications to the base product.
Derating Curves
Your Partners in Power...
Power Partners, Inc. | 43 Broad Street | Hudson, MA 01749
Tel: (978)567-9600 | Fax: (978)567-9601
Specifications subject to change.
PIL120U-C-DT: 7/30/2014
Website: www.powerpartners-inc.com