M10CC8xxD56N2A
Description: ZH Constant Current Linear LED Module Gen B
For use in Class 2 lighting systems
Zhaga-Hybrid Mounting Pattern
Suitable for DLC 4.0 Applications
Performance:
Nominal
(2)
Part Number Initial CRI
Current Power
Vf
Lm/W
(1)
(Amps) (Watts)
Lumens (Volts)
1.200 3860 22.1 26.5 146
1.050 3440 21.7 22.8 151
M10CC840D56N2A >82
0.700 2390 20.7 14.5 165
0.525 1825 19.6 10.3 177
0.350 1240 19.6 6.9 181
(1) MID Flux Bin Values are shown for CCT of 4000K. Tolerance of 10% at 45C
(2) Vf is at Tc of 45C with max tolerance of +/- 5%.
0.94
22.00
Mechanical Dimensions
General Performance Specifications
Length: 22.00
Lumen Maintenance : L85 50Khrs, t =75C
C
Width 0.94
Color Consistency: <3 SDCM)
Height: 0.25
Application:
Weight: 0.16 lbs
Min. Ambient Operating Temp.: -22F, -30C
Part Number Options
Max. Board Temp. (at t ): 185F, 90C
C
Part Number CCT Lumen Multiplier
Control Range: 100% to 1%
M10CC827D56N2A 2700K 93.5%
Maximum Current rating of 1.200 Amps
M10CC830D56N2A 3000K 95.2%
Regulatory
M10CC835D56N2A 3500K 96.8%
Recognized - UL8750
M10CC840D56N2A 4000K 100.0%
CAN/CSA-C22.2 No. 250.13-12
M10CC850D56N2A 5000K 103.0%
RoHS Compliant
M10CC851D56N2A 5100K 103.0%
Notes:
Performance data taken at Tc = 45C. Ordering Codes Description Qty/Ctn
Vf increases by 2% at 25C at initial turn on. M10CC8xxD56N2A00C Dry/Indoor Use Only, 4 Connectors 10
Vf increases by 10% at -30C at initial turn on. Dry/Indoor Use Only, 1 Connector
M10CC8xxD56N2AS0C 10
on each end
Power consumption and photometric performance are
Dry/Indoor Use Only, 2
typical values.
M10CC8xxD56N2AP0C 10
Connectors on one end only
Lumen maintenance value is based on LM80 testing
M10CC8xxD56N2AC0C Conformal Coat w/ 4 Connectors 10
and TM-21 calculation projections.
Application and operation performance specification information subject to change without
notification.
www.unvlt.com
Page 1 of 4
June 5, 2019M10CC8xxD56N2A
Flux and Voltage vs. Current
Notes:
Typical Values are shown for flux
and voltage graphs with Tc=45C.
Application and operation performance specification information subject to change without
notification.
www.unvlt.com
Page 2 of 4
June 5, 2019