Data sheet Weidmller Interface GmbH & Co. KG maxGUARD Klingenbergstrae 16 AMG CM D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Efficient machine and facility operation calls for fail-safe and maintenance-friendly control voltage distribution that can be installed in a time and space-saving manner. With the new maxGUARD system, the terminal blocks (previously installed separately) for distributing potential to the outputs of the electronic load monitors become an integral part of a 24 V DC control voltage distribution system. The innovative combination of load monitoring and potential distribution saves time during installation, increases safety against failure and reduces the amount of space required on the terminal rail by 50%. General ordering data Type AMG CM Order No. 2081900000 Version Control module, 24 V DC GTIN (EAN) 4050118419573 Qty. 1 pc(s). Creation date August 15, 2017 11:55:32 AM CEST Catalogue status 14.08.2017 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG maxGUARD Klingenbergstrae 16 AMG CM D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Technical data Dimensions and weights Width 12.2 mm Width (inches) 0.48 inch Height 125 mm Height (inches) 4.921 inch Depth 96.5 mm Depth (inches) 3.799 inch Net weight 56 g Temperatures Operating temperature -25 C...55 C Storage temperature -40 C...85 C Probability of failure MTTF 410 Years Input Connection system PUSH IN Current consumption (full load) 225 mA Current consumption (idle) 25 mA DC input voltage range 1830 V DC Input fuse (internal) No Rated input voltage 24 V DC Surge protection max. admissible residual ripple at the Suppressor diode input 100 mVpp output Connection system PUSH IN Surge protection Suppressor diode General data Control inputs ON/ OFF, Reset Operating temperature -25 C...55 C Protection degree IP20 Relay to activate the output No Surge voltage category III Insulation coordination Surge voltage category III Connection data (input) Conductor cross-section, AWG/kcmil , Conductor cross-section, AWG/kcmil , max. 12 min. 26 Conductor cross-section, flexible , min. 0.14 mm Conductor cross-section, rigid , max. 2.5 mm Conductor cross-section, rigid , min. 0.14 mm Connection system PUSH IN Number of terminals 2 (Reset / ON) Screwdriver blade 0.6 x 3.5 Wire connection cross section, flexible (input), max. 2.5 mm Connection data (output) Conductor cross-section, AWG/kcmil , Conductor cross-section, AWG/kcmil , max. 12 min. 26 Conductor cross-section, flexible , max. 2.5 mm Conductor cross-section, flexible , min. 0.14 mm Conductor cross-section, rigid , max. 2.5 mm Conductor cross-section, rigid , min. 0.14 mm Connection system PUSH IN Number of terminals 2 (I< / Alarm) Screwdriver blade 0.6 x 3.5 Creation date August 15, 2017 11:55:32 AM CEST Catalogue status 14.08.2017 / We reserve the right to make technical changes. 2