Product Specification 1 West P6100 / Din Process Controller 16 With its improved interface, technical functionality and field flexibility, the West 6100 gives you the best in comprehensive control for most temperature and process control loops. Jumperless Configuration Auto or Manual Tuning Auto Detected Hardware Heat/Cool Operation Process & Loop Alarms Ramping Setpoint Modbus & ASCII Comms Remote/Dual Setpoint Options Technical Data Features Control Types Full PID with Pre-tune, Self-tune, manual tuning, or On-Off control. Heat only or heat & cool Auto/Manual Selectable from front panel or via digital input, with bumpless transfer Output Configuration Up to 3 possible, for control, alarm, 24VDC transmitter power supply or retransmit of process value or setpoint Alarm 1 & 2 Types Process high, process low, SP deviation, band, logical OR / AND. Also 1 loop alarm for process control security. Process alarms have adjustable hysteresis. Human Interface 4 button operation, dual 4 digit 10mm & 8mm high LED displays, optional choice of colours (Red/Red, Red/Green, Green/Red or Green/Green), plus 5 LED indicators PC Configuration Off-line configuration from PC serial port to dedicated config socket (comms option not required). Configuration Software for Windows 98 or higher. West Part Number: PS1-CON Input Thermocouple J, K, C, R, S, T, B, L, N & PtRh20%vsPtRh40%. RTD 3 Wire PT100, 50 per lead maximum (balanced) DC Linear 0 to 20mA, 4 to 20mA, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V. Scaleable -1999 to 9999, with adjustable decimal point Impedance >10M for Thermocouple and mV ranges, 47K for V ranges and 5 for mA ranges Accuracy 0.1% of input range 1 LSD (T/C CJC better than 1C) Sampling 4 per second, 14 bit resolution approximately Sensor Break Detection <2 seconds (except zero based DC ranges), control O/Ps turn off, high alarms activate for T/C and mV ranges, low alarms activate for RTD, mA or V ranges Outputs & Options Control & Alarm Relays Contacts SPDT 2 Amp resistive at 240V AC, >500,000 operations Control SSR Driver Outputs Drive capability >10V DC in 500 minimum Triac Outputs 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz DC Linear Outputs 0 to 20mA, 4 to 20mA into 500 max, 0 to 10V, 2 to 10V, 0 to 5V into 500 min. Control outputs have 2% over/under drive applied. Accuracy 0.25% at 250 (degrades linearly to 0.5% for increasing burden to specified limits) Transmitter Power Supply Output 24VDC (nominal) into 910 minimum to power external devices Communications 2 Wire RS485, 1200 to 19200 Baud, Modbus and ASCII protocol (selectable) Digital Input Selects between 2 setpoints or Auto/Manual control. Volt free or TTL input Remote Setpoint Input 0 to 20mA, 4 to 20mA, 0 to 5V, 1 to 5V, 0 to 10V or 2 to 10V. Scaleable -1999 to 9999. Local/Remote setpoint selected from front panel Operating & Environmental Temperature & RH 0 to 55C (-20 to 80C storage), 20% to 95% RH non-condensing Power Supply 100 to 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts) Front Panel Protection IEC IP66 (Behind panel protection is IP20) Standards CE, UL & ULC recognised In accordance with our policy of continuous improvement, we reserve the right to change specifications from those shown in this document P6100 Spec sheet - 06/04West Instruments Tel: +44 (0) 1273 606271 e-mail: info westinstruments.com The Hyde Business Park Fax: +44 (0) 1273 609990 Web: www.westinstruments.com Brighton BN2 4JU, UK 10mm (approx) Dimensions Cut-out 48mm 110mm 45 x 45mm +0.5 0.0 45 x 45mm +0.5 0.0 Connection Details Field Reconfiguration Input Jumper-free configuration for any type (no extra parts required) Option Slot 1 Part Number Relay Output...........................PO1-C10 Linear mA/V DC Output ..........PO1-C21 SSR Driver Output ..................PO1-C50 Triac Output ............................PO1-C80 Option Slot 2 Part Number Relay Output...........................PO2-C10 Linear mA/V DC Output ..........PO2-C21 SSR Driver Output ..................PO2-C50 Triac Output ............................PO2-C80 Option Slot 3 Part Number Relay Output...........................PO2-C10 Linear mA/V DC Output ..........PO2-C21 SSR Driver Output ..................PO2-C50 24VDC Transmitter PSU........ PO2-W08 Option Slot A Part Number Digital Input............................ PA1-W03 Remote Setpoint Input (Basic)PA1-W04 RS485 Comms....................... PA1-W06 Order Code P6100 - x - x - x - x - x - x - x Input Type Display Colour 3 Wire RTD or DC mV 1 0 Red Upper & Lower Thermocouple 2 1 Green Upper & Lower DC mA 3 2 Red Upper, Green Lower DC Voltage 4 3 Green Upper, Red Lower Option Slot 1 Power Supply Not fitted 0 0 100-240V AC Relay 1 2 24-48V AC or DC DC for SSR 2 Option Slot A DC 0-10V 3 0 Not fitted DC 0-20mA 4 1 RS485 Communications DC 0-5V 5 3 Digital Input DC 2-10V 6 4 Basic Remote Setpoint Input DC 4-20mA 7 Option Slot 3 Triac 8 0 Not fitted Option Slot 2 1 Relay Not fitted 0 2 DC Driver for SSR Relay 1 3 DC 0-10V DC Driver for SSR 2 4 DC 0-20mA DC 0-10V 3 5 DC 0-5V DC 0-20mA 4 6 DC 2-10V DC 0-5V 5 7 DC 4-20mA DC 2-10V 6 8 Transmitter Power Supply DC 4-20mA 7 Triac 8 West Instruments is a division of Danaher (UK Industries) Ltd. A member of the Danaher Corporation. Registered in England No 2815444 VAT No GB788620583 Registered Office: Danaher House, Parkway One Business Centre, Parkway Drive, Sheffield, S9 4WU 48mm