Product Specification 1 West P6010 / Din Panel Indicator 16 The P6010 has multi-point scaling, tare function and improved flexibility. It has a universal input and is available with a red or green display. Plug-in modules allow up to four alarm relays (latching or non-latching), PV retransmission or transmitter PSU. Jumperless Configuration Min/max Value Hold Auto Detected Hardware Tare (auto-zero) Function Up to 4 Alarm Outputs Multi-point Scaling Modbus & ASCII Comms PC configuration Technical Data Features Output Configuration Up to 4 total. Max 3 single/1 dual relay, max 1 retransmit of PV, max 1 transmitter power supply Alarms Up to 5. Process high low or logical OR (direct or reverse acting). With adjustable hysteresis Viewable Values Process variable, maximum value, minimum value and alarm 1 elapsed time since reset Human Interface 3 button operation, 4 digit 10mm high red or green display, plus 3 alarm 1 max and 1 min indicator PC Configuration Off-line configuration from PC serial port to dedicated config socket (comms option not required). Configuration Software for Windows 98 or higher. West Part Number: PS1-CON Input Thermocouple J, K, C, R, S, T, B, L, N & PtRh20%vsPtRh40%. RTD 3 Wire PT100, 50 per lead maximum (balanced) DC Linear 0 to 20mA, 4 to 20mA, 0 to 50mV, 10 to 50mV, 0 to 5V, 1 to 5V, 0 to 10V, 2 to 10V. Scaleable -1999 to 9999, with adjustable decimal point Impedance >10M for Thermocouple and mV ranges, 47K for V ranges and 5 for mA ranges Accuracy 0.1% of input range 1 LSD (T/C CJC better than 1C) Sampling 4 per second, 14 bit resolution approximately Sensor Break Detection <2 seconds (except zero based DC ranges), high alarms activate for T/C, RTD and mV ranges, low alarms activate for mA or V ranges Outputs & Options Single Alarm Relays Contacts SPDT 2 Amp resistive at 240V AC, >500,000 operations. Latching or non-latching Dual Alarm Relay Two x SPST contacts with shared common. 2 Amp resistive at 240V AC, >200,000 operations. Latching or non-latching SSR Driver Outputs Drive capability >10V DC in 500 minimum Triac Outputs 0.01 to 1 Amp AC, 20 to 280Vrms, 47 to 63Hz DC Linear Retransmit Outputs 0 to 20mA, 4 to 20mA into 500 max, 0 to 10V, 2 to 10V, 0 to 5V into 500 min. Accuracy 0.25% at 250 (degrades linearly to 0.5% for increasing burden to specified limits) Transmitter Power Supply Output 24VDC (nominal) into 910 minimum to power external devices Serial Communications 2 Wire RS485, 1200 to 19200 Baud, Modbus and ASCII protocol (selectable) Digital Input External reset of latched relay, stored alarm 1 elapsed time, stored min/max PV values or initiate tare function. Volt free or TTL input Operating & Environmental Temperature & RH 0 to 55C (-20 to 80C storage), 20% to 95% RH non-condensing Power Supply 100 to 240V 50/60Hz 7.5VA (optional 20 to 48V AC 7.5VA/22 to 65V DC 5 watts) Front Panel Protection IEC IP66 (Behind panel protection is IP20) Standards CE, UL & ULC recognised. Pollution Degree 2, Installation Category II In accordance with our policy of continuous improvement, we reserve the right to change specifications from those shown in this document P6010 Spec sheet - 03/05Authorised distributor: Ward Industries Limited Tel: +44 (0) 1933 624963 Fax: +44 (0) 1933 625458 Email: sales wardindustries.co.uk Web: www.wardindustries.co.uk 10mm (approx) Dimensions Cut out 48mm 110mm 45mm +0.5 Connection Details Field Reconfiguration Input Jumper-free configuration for any type (no extra parts required) Option Slot 1 Part Number Relay Output...........................PO1-C10 Linear mA/V DC Output ..........PO1-C21 SSR Driver Output ..................PO1-C50 Triac Output ............................PO1-C80 Option Slot 2 Part Number Relay Output...........................PO2-C10 Dual Relay Output.................. PO2-W09 Linear mA/V DC Output ..........PO2-C21 SSR Driver Output ..................PO2-C50 Triac Output ............................PO2-C80 Option Slot 3 Part Number Relay Output...........................PO2-C10 Linear mA/V DC Output ..........PO2-C21 SSR Driver Output ..................PO2-C50 24VDC Transmitter PSU........ PO2-W08 Option Slot A Part Number Digital Input............................ PA1-W03 RS485 Comms....................... PA1-W06 P6010 - x - x - x - x - x - x - x Order Code Input Type Display Colour 3 Wire RTD or DC mV 1 0 Fixed Red Thermocouple 2 1 Fixed Green DC mA 3 Power Supply DC Voltage 4 0 100-240V AC Option Slot 1 2 24-48V AC or DC Not fitted 0 Option Slot A Relay 1 0 Not fitted DC for SSR 2 1 RS485 Communications DC 0-10V 3 3 Digital Input DC 0-20mA 4 Option Slot 3 DC 0-5V 5 0 Not fitted DC 2-10V 6 1 Relay DC 4-20mA 7 2 DC Driver for SSR Triac 8 3 DC 0-10V Option Slot 2 4 DC 0-20mA Not fitted 0 5 DC 0-5V Relay 1 6 DC 2-10V DC Driver for SSR 2 7 DC 4-20mA DC 0-10V 3 8 Transmitter Power Supply DC 0-20mA 4 DC 0-5V 5 DC 2-10V 6 DC 4-20mA 7 Triac 8 Dual Relay 9 West Instruments is a division of Danaher (UK Industries) Ltd. A member of the Danaher Corporation. Registered in England No 2815444 VAT No GB788620583 Registered Office: Danaher House, Parkway One Business Centre, Parkway Drive, Sheffield, S9 4WU 48mm 45mm +0.5