Dimensions: mm Recommended Land Pattern: mm Absolute Maximum Ratings (Ambient Temperature 25C): Properties Test conditions Value Unit 1,96 0,1 Power Dissipation P 6600 mW Diss 0,94 0,1 I Peak Forward Current duty/ 10 10 kHz 5000 mA 1,2 2,2 F Peak I Continuous Forward Current 3000 mA F ESD Threshold/ Human Body V 1000 V Model ESD HBM Optical Properties: Chip Technology AlGaAs Emitting Color Infrared 0,4 0,1 0,4 Lens Type Diffused Plastic Housing Color Black 3,5 0,1 Scale - 7:1 General Information: Operating Temperature -20 up to +85 C Schematic: Storage Conditions (in original < 40 C < 90 % RH packaging) Storage Conditions (for single -20 up to +85 C parts) Anode Mark Moisture Sensitivity Level (MSL) 3 + - 1 2 IR LEDs emit high intensity IR light. Do not look directly into the LED during operation. This can be harmful to your eyes. 3,0 0,1 Wear protective eyewear. Please f ollow safety precautions given in Scale - 7:1 IEC 60825-1 and IEC 62471. Keep out of reach of children. Avoid direct eye and skin exposure to LED CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD ZAn 001.001 2021-10-25 DIN ISO 2768-1m DESCRIPTION WL-VCSL Vertical Cavity surface Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions emitting Laser Max-Eyth-Str. 1 159353850A6300 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 3535 eiPal Valid 1/10 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. 2,7 0,1 3,3 0,1 3,5 0,1 1,77 0,1 3,3 CAUTION IRElectrical & Optical Properties: Viewing Angle X Direction: Properties Test conditions Value Unit Peak Wavelength 3000 mA 850 nm Peak Radiant Flux 3000 mA 2100 mW e V Forward Voltage 3000 mA 2.1 V F Spectral Bandwidth 3000 mA 2 nm Slope Efficiency SE 0.9 W/A Energy Conversion Efficiency 3000 mA 33 % EC Viewing Angle (X-Axis) 2 3000 mA 60 50%,X 2 Viewing Angle (Y-Axis) 3000 mA 45 0 -30 50%,Y I Threshold Current 0.65 A Th Certification: 45 RoHS Approval Compliant 2011/65/EU&2015/863 50 REACh Approval Conform or declared (EC)1907/2006 55 60 65 70 75 80 85 90 -90 -45 0 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE PROJECTION METHOD ZAn 001.001 2021-10-25 DIN ISO 2768-1m DESCRIPTION WL-VCSL Vertical Cavity surface Wrth Elektronik eiSos GmbH & Co. KG ORDER CODE EMC & Inductive Solutions emitting Laser Max-Eyth-Str. 1 159353850A6300 74638 Waldenburg Germany SIZE/TYPE BUSINESS UNIT STATUS PAGE Tel. +49 (0) 79 42 945 - 0 www.we-online.com 3535 eiPal Valid 2/10 eiSos we-online.com This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Wrth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Wrth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Relative Intensity (%)