ECP180 Series Low 1 Profile High Power Density 2.0 by 4.0 Footprint 120W Convection-cooled Rating 180W Force Cooled Rating Medical & ITE Approvals Class I and Class II Applications High Efficiency, up to 94% Less than 0.5W No Load Input Power Built-In Fan Supply Low Earth Leakage Current 5000m Operating Altitude GREEN POWER EEN PO The ECP180 series has been designed to minimise no load power consumption and maximise efficiency facilitating equipment design to meet the latest environmental legislation and minimising power loss and heating within equipment enclosures. Approved for medical and ITE applications, this range of single output AC/DC power supplies are packaged in an ultra-low profile 1 height with a foot print of just 2.0 by 4.0. The ECP180 series is suitable for for us in both class I and class II applications. 3 The ECP180 provides up to 180W force-cooled or 120W convection-cooled leading to very high power densities of 22W/in or 3 15W/in respectively. A 12V, 500mA fan supply is included in the design. The power supply contains two fuses and low leakage currents as required by medical applications and is safety approved to operate in a 70 C ambient. The low profile and safety approvals covering ITE and medical standards for both class I and class II applications along with conducted emissions meeting EN55011/32 level B allow the versatile ECP180 series to be used in a vast range of applications. xppower.com Models and Ratings Output Current Ripple and Noise (3) (4) Output Voltage Fan Output Efficiency Model Number (2) (1) pk-pk Convection-cooled Forced-cooled 12.0 V 10.00 A 15.00 A 120 mV 12 V/0.5 A 92% ECP180PS12 15.0 V 8.00 A 12.00 A 150 mV 12 V/0.5 A 92% ECP180PS15 24.0 V 5.00 A 7.50 A 240 mV 12 V/0.5 A 93% ECP180PS24 28.0 V 4.30 A 6.43 A 280 mV 12 V/0.5 A 93% ECP180PS28 36.0 V 3.33 A 5.00 A 360 mV 12 V/0.5 A 94% ECP180PS36 48.0 V 2.50 A 3.75 A 480 mV 12 V/0.5 A 94% ECP180PS48 Notes: 1. Requires 10 CFM. 2. Measured with 20 MHz bandwidth and 10 F electrolytic capacitor in parallel with 0.1 F ceramic capacitor 3. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of 180 W load and 230 VAC input. Input Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Derate output from 120 W at 100 VAC to 110 W Input Voltage - Operating 85 115/230 264 VAC at 90 VAC and 100 W at 85 VAC when convection-cooled Input Frequency 47 50/60 63 Hz Agency approval 47-63 Hz 230 VAC, 100% load EN61000-3-2 class A > Power Factor 0.9 EN61000-3-2 class C > 145W Input Current - Full Load 1.8/0.9 A 115/230 VAC Inrush Current 80 A 230 VAC cold start, 25 C Earth Leakage Current 85/150 230 A 115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.) No Load Input Power 0.5 W Input Protection F3.15 A/250 V Internal fuse fitted in line and neutral. Output Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 48 VDC See Models and Ratings table Initial Set Accuracy 1 % 50% load, 115/230 VAC Minimum Load 0 A Start Up Delay 2 s 115/230 VAC full load. See fig. 3 & 4. Hold Up Time 10 17/11 ms Min at full load, 115 VAC. Typical at 120W/180W Drift 0.02 % After 20 min warm up Line Regulation 0.5 % 90-264 VAC Load Regulation 0.5 % 0-100% load Recovery within 1% in less than 500 s Transient Response 4 % for a 50-75% and 75-50% load step Over/Undershoot 4 % Full Load 20 MHz bandwidth & 10 F electrolytic capacitor Ripple & Noise 1 % pk-pk in parallel with 0.1 F ceramic capacitor, See fig. 6. Overvoltage Protection 110 140 % Vnom, recycle input to reset Overload Protection 110 160 % I nom See fig. 1. Short Circuit Protection Trip and Restart See fig. 2. Temperature Coefficient 0.02 %/ C Overtemperature Protection C Measured Internally, Auto Resetting 2