xppower.com 300 2400 Watts MP Series Configurable for Fast Time to Market 1 to 24 Outputs Floating Outputs Fully Featured Signal Set SEMI F47 Compliant Extra Power Available at High Line 3 Year Warranty Specification Input General Input Voltage 90-264 VAC Efficiency 75% typical at nominal input Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output 1500 VAC Input to Ground Inrush Current 40 A max at 230 VAC, cold start 25 C 500 VAC Output to Ground Power Factor Compliant with EN61000-3-2, Class A Signals & Controls AC OK, DC OK, Current share, Global Earth Leakage Current <1.5 mA Inhibit, Module Inhibit, Remote Sense, Input Protection F3/FF: Internal T6.3 A/250 V fuse in line Voltage Programming & 5V Standby F4/F6: Internal T10 A/250 V fuse in line MTBF 750 kHrs Demonstrated F7: Internal T12 A/250 V fuse in line F8: Internal T15 A/250 V fuse in line Environmental FX: Internal T20 A/250 V fuse in line Operating Temperature 0 C to +70 C, derate linearly from 100% Output at +50 C to 50% at +70 C for standard models. Derate linearly from 100% at Output Voltage See module table +40 C to 50% at +60 C for reverse Output Voltage Trim 5% typical all outputs air models. Hold Up Time 20 ms min Storage Temperature -40 C to +85 C Line Regulation Typically 0.1%, maximum 0.3% Operating Altitude 3000 m Load Regulation 1% max for single output modules Shock 30 g, 11 ms (half sine), 3 shocks each & V1 of dual & triple output modules. axis, 18 shocks total. Compliant with 2% max for V2 & V3 of dual & triple EN60068-2-27 output modules. The E module requires Vibration 2 g, 10-500 Hz, 10 sweeps 3 axes. up to 10% load & the K module up to 5% Compliant with EN60068-2-6 load on V1 to achieve the specified regulation figures on V2 & V3 EMC & Safety Ripple & Noise 50 mV or 1% pk-pk, whichever is greater, 20 MHz bandwidth Emissions EN55022, level B conducted Overvoltage Protection 115-130% Vnom for single output and Harmonic Currents EN61000-3-2, Class A output 1 of dual & triple output modules. Voltage Flicker EN61000-3-3 No OVP fitted to G modules or H modules. ESD Immunity EN61000-4-2, level 3 Perf Criteria A Overload Protection <140% of nominal rating Radiated Immunity EN61000-4-3, level 3 Perf Criteria A Short Circuit Protection Continuous trip & restart (Hiccup mode) EFT/Burst EN61000-4-4, level 3 Perf Criteria A Temperature 0.03%/C Surge EN61000-4-5, level 3 Perf Criteria A Coefficient Conducted Immunity EN61000-4-6, level 3 Perf Criteria A Remote Sense See signals & controls page Dips & Interruptions EN61000-4-11, 30% 10 ms, Current Share Single wire parallel current share. 60% 100 ms, 100% 5000 ms, See signals & controls page Perf Criteria A, B, B Inhibit TTL compatible. Safety Approvals EN60950, UL60950, CSA22.2-No 950 See signals & controls page CE Mark LVD, SEMI F47 compliant (high line only) AC DCAC DC MP Model Selection & Power Supply Construction STEP 1 In order to configure a model number for your MP Series power supply first select the appropriate chassis, dependent on your applications continuous, maximum output power requirements. STEP 2 Next, from the ratings on the following page, select the output modules that suit your output voltage and current requirements. Modules can be positioned as denoted by the , and sequence shown below. STEP 3 Once the chassis & output modules have been selected, form the model number as shown below. (1) (1) (1) (1) (1) (1) (1) F3 (300 W) & FF (350 W) F4 (400 W) & F6 (600 W) & F7 (700 W) F8 (800 W) & FX (1000 W) Module Position Module Position Module Position 32 1 43 2 1 65 4 3 2 1 Note 1. Output power can be increased by 200 W if used at 181-264 VAC input, FF chassis 175 W, F6 chassis 150 W. Model Number Construction Chassis Option Module Module Module Module Module Module Option Power Position 1 Position 2 Position 3 Position 4 Position 5 Position 6 F 7 B 3 J 6 J 6 G 2 - 22 1R Add the chassis Add Module 1 Add Module 2 Add Module 4 Add Module 5 Add Module 6 Add Module 3 Add Option Codes code first. B3 = Single O/P J6 = Single O/P J6 = Single O/P G2 = Dual O/P F8 & FX F8 & FX F7 = 5 V 60 A 24 V 8 A 24 V 8 A 15 V 3 A only only Denotes Denotes 700W Chassis 15 V 3 A J6 modules reverse F4, F6, F7, F8 & in parallel air flow FX only to give 24 V 16 A (For single slot, single O/P modules ( ), insert highest power first and the lowest voltage if power is equal.) Option Codes No. Option Function 01 2 x B modules parallel connect in slots 1 & 2 02 2 x B modules parallel connect in slots 2 & 3 03 2 x B modules parallel connect in slots 3 & 4 04 4 x B modules 2 x B modules parallel connect in slots 1 & 2 and 2 x B modules parallel connect in slots 3 & 4 05 2 x C modules parallel connect in slots 1 & 2 (2 V to 8 V) 06 2 x C modules parallel connect in slots 1 & 2 (18 V to 48 V) 21 2 x J modules parallel connect in slots 1 & 2 22 2 x J modules parallel connect in slots 2 & 3 23 2 x J modules parallel connect in slots 3 & 4 24 2 x J modules parallel connect in slots 4 & 5 25 2 x J modules parallel connect in slots 5 & 6 1R Reverse Air fans in exhaust configuration using standard fans 1S Low Noise standard (air inflow) configuration using low noise fans (F8 & FX only) 2R Reverse Air fans in exhaust configuration using low noise fans (F8 & FX only) Note: 1. Consult sales for 1200-2400 W model numbers.