AC-DC Power Supplies XPPower HDS1500 Series 1500 Watts High Efficiency up to 92% xxx Series High Power Density Programmable Output Voltage (0-105%) Programmable Output Current (0-105%) Parallel Operation Fully Featured Signals & Controls 3 Year Warranty The HDS1500 series offers users both output voltage and output current programming Dimensions: 2 (0 105%) via resistance, voltage or I C bus in a very high efficiency, high power density HDS1500: 1.5 kW chassis mount package. Measuring just 12.32 x 2.5 x 5.0, the HDS1500 also 12.32 x 2.50 x 5.00 (294.5 x 63.5 x 127 mm) features active current sharing, remote on/off, remote sense and a power OK signal. The standby output is available whenever the mains supply is present and can be user selected as either 5 V at 0.5 A or 9V at 0.3 A. Models & Ratings Output Current (1) Output Power Output Voltage V1 Efficiency Model Number Min Max 1500 W 12.0 VDC 0.0 A 125.0 A 89% HDS1500PS12 1500 W 15.0 VDC 0.0 A 100.0 A 90% HDS1500PS15 1500 W 24.0 VDC 0.0 A 62.5 A 91% HDS1500PS24 1500 W 30.0 VDC 0.0 A 50.0 A 92% HDS1500PS30 1500 W 36.0 VDC 0.0 A 41.7 A 92% HDS1500PS36 1500 W 48.0 VDC 0.0 A 31.3 A 92% HDS1500PS48 1500 W 60.0 VDC 0.0 A 25.0 A 93% HDS1500PS60 Notes 1. Measured with 230 VAC input and full load. Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC See derating curve Input Frequency 47 63 Hz Power Factor 0.99/0.98 115/230 VAC full load Input Current 18/9 A 115/230 VAC Inrush Current 30.0/60/0 A 115/230 VAC Earth Leakage Current 1.0 mA 264 VAC/60 Hz Input Protection F20 A/250 V internal fuse www.xppower.com 1AC-DC Power Supplies XPPower HDS1500 Series Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 60 VDC See Models and Ratings table Output Trim 5.0 % By potentionmeter Output Voltage Program 0 105 % Of rated output Output Current Program 0 105 % Of rated output Initial Set Accuracy 1 % Minimum Load 0 A Start Up Delay 1 s Start Up Rise Time 120 ms At full load Hold Up Time 8 ms Line Regulation 1 % Load Regulation 1/3 % 0-100% load. V1/5V standby Transient Response 1 % For a 25% step load change 1.25% for 12 V model. Measured with 20 MHz bandwidth Ripple & Noise 1 % pk-pk and using 12 twisted pair wire terminated with 0.1 F ceramic capacitor and 47 F electrolytic. Tracks output voltage, see application notes Overvoltage Protection Recycle AC to reset Primary and secondary heatsinks, monitored Overtemperature Protection Output shuts down, auto recovers Overload Protection 105 % Rated power, constant current Short Circuit Protection Auto recovery Temperature Coefficient 0.02 %/C 0-50 C Remote Sense Compensates for 0.5 V max voltage drop, if remote sense is not required, local sense must be used Enable Output must be enabled, see application notes, power supply is shipped with enable links fitted Current Share 5 supplies can share within 5% Standby Output 5 V at 0.5 A, present whenever AC is applied (9 V at 0.3 A, user selectable, by connecting VSET, Pin 8 of CN2 to GND) Output Voltage Programming Via External Voltage Via External Resistor 120 120 100 100 80 80 60 60 40 40 20 20 0 0 01 23 454.5 4.8 01 23 454.5 4.8 Programming Voltage (VDC) Resistor Value (k) Output Current Programming Via External Voltage Via External Resistor 120 120 100 100 80 80 60 60 40 40 20 20 0 0 01 23 454.5 4.8 01 23 454.5 4.8 Resistor Value (k) Programming Voltage (VDC) www .xppower.com 2 Output Current (%) Output Voltage (%) Output Current (%) Output Voltage (%)