AC-DC Power Supplies XPPower HDS3000 Series 3000 Watts High Efficiency up to 93% xxx Series High Power Density Programmable Output Voltage (0-105%) Programmable Output Current (0-105%) Parallel Operation Fully Featured Signals & Controls 3 Year Warranty The HDS3000 series offers users both output voltage and output current programming Dimensions: 2 (0 105%) via resistance, voltage or I C bus in a very high efficiency, high power density HDS3000: 3 kW chassis mount package. Measuring just 5 x 5 x 14.41, the HDS3000 also 14.41 x 5.00 x 5.00 (366 x 127 x 127 mm) features active current sharing, remote on/off, remote sense and a power OK signal. The standby output is available whenever the mains supply is present and can be user selected as either 5 V at 0.5 A or 9V at 0.3 A. Models & Ratings Output Current (1) Output Power Output Voltage V1 Ripple & Noise Efficiency Model Number Min Max 3000 W 12.0 VDC 0.0 A 250.0 A 150 mV 89% HDS3000PS12 3000 W 15.0 VDC 0.0 A 200.0 A 150 mV 90% HDS3000PS15 3000 W 24.0 VDC 0.0 A 125.0 A 200 mV 91% HDS3000PS24 3000 W 30.0 VDC 0.0 A 100.0 A 200 mV 91% HDS3000PS30 3000 W 36.0 VDC 0.0 A 83.5 A 200 mV 92% HDS3000PS36 3000 W 48.0 VDC 0.0 A 62.5 A 200 mV 92% HDS3000PS48 3000 W 60.0 VDC 0.0 A 50.0 A 300 mV 93% HDS3000PS60 Notes 1. Measured with 230 VAC input and full load. Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC See derating curve Input Frequency 47 63 Hz Power Factor 0.99/0.98 115/230 VAC full load Input Current 36.0/18.0 A 115/230 VAC Inrush Current 60.0/90.0 A 115/230 VAC Earth Leakage Current 2.5 mA 264 VAC/60 Hz Input Protection 2 x F20 A/250 V internal fuse www.xppower.com 1AC-DC Power Supplies XPPower HDS3000 Series Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 60 VDC See Models and Ratings table Output Trim 5.0 % By potentionmeter Output Voltage Program 0 105 % Of rated output Output Current Program 0 105 % Of rated output Initial Set Accuracy 1 % Minimum Load 0 A Start Up Delay 2 s Start Up Rise Time 150 ms At full load Hold Up Time 8 ms Line Regulation 1.0 % (V1) Load Regulation 1 /3 % 0-100% load. V1/5 V Standby Transient Response <1 % For a 25% step load change See models and ratings table. Measured with 20 MHz bandwidth and using 12 twisted Ripple & Noise 150 300 mV pk-pk pair wire terminated with 0.1 F ceramic capacitor and 47 F electrolytic. Tracks output voltage, see application notes Overvoltage Protection Recycle AC to reset Primary and secondary heatsinks, monitored Overtemperature Protection Output shuts down, auto recovers Overload Protection 105 % Rated power, constant current Short Circuit Protection Auto recovery Temperature Coefficient 0.02 %/C 0-50 C Remote Sense Compensates for 0.5 V max voltage drop, if remote sense is not required, local sense must be used Enable Output must be enabled, see application notes, power supply is shipped with enable links fitted Current Share 5 supplies can share within 5% Standby Output 5 V at 0.5 A, present whenever AC is applied (9 V at 0.3 A, user selectable, by connecting VSET, Pin 8 of CN2 to GND) Output Voltage Programming Via External Voltage Via External Resistor 120 120 100 100 80 80 60 60 40 40 20 20 0 0 01 23 454.5 4.8 01 23 454.5 4.8 Programming Voltage (VDC) Resistor Value (k) Output Current Programming Via External Voltage Via External Resistor 120 120 100 100 80 80 60 60 40 40 20 20 0 0 01 23 454.5 4.8 01 23 454.5 4.8 Programming Voltage (VDC) Resistor Value (k) www .xppower.com 2 Output Voltage (%) Output Current (%) Output Voltage (%) Output Current (%)