PLS600 Series BENCH POWER SUPPLIES 600W The PLS600 is a programmable DC power supply with a single output that oerff s output power to 600 watts. With 12-bit D/A & A/D converters embedded, the power supplies come with the capability of reporting voltage and current very accurately. The PLS600 series provides convenient digital rotary controls for voltage and current adjustment. The power supplies also come with rear ports that allow remote control via USB, Ethernet, and analog control inputs. The USB and Ethernet inputs are SCPI compliant and have LabView drivers available on the National Instruments website. The PLS600 series is LXI certified, details for using this interface can be found in the Programming Manual. Applications Resource Links Click Here for the Programming Manual Click Here for the User Manual Technology Laboratory Industrial Electronics Features Output Voltage & Current (1) Current Power Model Number Voltage PLS6003033 30V 33A PLS6005020 50V 20A PLS60010010 100V 10A 600W PLS6002005 200V 5A PLS6004002.5 400V 2.5A (1) PLS600 series pr oduct are shipped without a mains lead. For US mains lead order part US-MAINS-IEC. For EU main lead order part EU-MAINS-IEC. For UK mains lead order par UK-MAINS-IEC. (2) 1U Rack Mount kit available. Order part number PLS600 RACK KIT for 1 or 2 x PLS600. Rotary Controls The digital rotary controls allow both fine and rapid adjustment of the output voltage and current. They are velocity sensitive so that a slow turn allows fine adjustment of voltage or current and rapid turning quickly adjusts voltage or current over a large range. Precise voltage and current measurement Besides the precise output, the PLS600 series also oerff s the capability to measure voltage & current accurately (read back), saving users the extra expense and space for extra measuring instruments. This capability is available from the display or the readings may be read into the controlling device. OVP (over voltage protection), OCP (over current protection) and OPP (over power protection) functions The over voltage protection (OVP), over current protection (OCP) and over power protection (OPP) features limit the maximum output current and voltage to avoid damage to the unit under test (UUT). Series and parallel capability Up to 4 units can be connected in (master/slave mode) and up to 2 units can be connected in series.BENCH POWER SUPPLIES PLS600 Series Specification Unless otherwise noted, specifications are warranted over the ambient temperature range of 0 to 40C. PLS6003033 PLS6005020 PLS60010010 PLS6002005 PLS6004002.5 Voltage 30V 50V 100V 200V 400V (1) DC Output Ratings Current 33A 20A 10A 5A 2.5A Power 600W 600W 600W 600W 600W (3) CV p-p 60mV 60mV 60mV 60mV 60mV Output Ripple & Noise (4) CV rms 20mV 20mV 20mV 20mV 20mV Voltage 15mV 15mV 15mV 15mV 15mV Load Regulation (change from 10%-90% load) Current 15mA 15mA 15mA 15mA 15mA Voltage 15mV 15mV 15mV 15mV 15mV Line Regulation (5) (change from 100-132 or 180-260 VAC input) Current 15mA 15mA 15mA 15mA 15mA Voltage 0.1%+ 15mV 15mV 15mV 15mV 15mV (1,2) Programming Accurancy Current 0.1%+ 66mA 66mA 66mA 66mA 66mA Voltage 0.1%+ 15mV 15mV 15mV 15mV 15mV Measurement Accuracy Current 0.1%+ 60mA 60mA 60mA 60mA 60mA (5) Transient Recovery Time Time 1ms 1ms 1ms 1ms 1ms Supplemental Characteristics (supplemental characteristics are not warranted but are descriptions of typical performance determined either by design or type testing) Up, Full Load 0.08s 0.08s 0.08s 0.08s 0.08s Output Response Time (settle to within 1% of the rated output, Down, Full Load 0.08s 0.08s 0.08s 0.08s 0.08s with resistive load) Down, No Load 0.5s 0.5s 0.5s 0.5s 0.5s (6) Command Response Time Time 50ms 50ms 50ms 50ms 50ms (7) Data Readback Transfer Time Time 5ms 5ms 5ms 5ms 5ms Remote Sense Compensation Volts/Load Lead 1V 1V 2V 4V 4V Range 0.5-33V 0.5-55V 0.5-110V 0.5-220V 0.5-440V Over-voltage Protection Accuracy 0.3V 0.5V 1V 2V 4V (3) Output Ripple & Noise CC rms 7mA 5mA 5mA 5mA 10mA Voltage 0.05%+ 10mV 25mV 50mV 100mV 200mV Programming Resolution Measurement Resolution Current 0.05%+ 20mA 20mA 10mA 5mA 2.5mA Voltage 0.1%+ 10mV 25mV 50mV 100mV 200mV Front Panel Display Accuracy Current 0.1%+ 33mA 20mA 10mA 5mA 2.5mA 1. Minimum voltage is guaranteed at greater than 1% of the rated output voltage. 2. Minimum current is guaranteed at greater than 1% of the rated output current. 3. Measured with 20MHz bandwidth and excluding line frequency ripple. 4. Line frequency ripple measured with 20MHz bandwidth. 5. Time for output voltage to recover within 0.5% of its rated output for a load change from 10 to 90% of its rated output current. 6. Add this to the output response time to obtain the total programming time. 7. Time to provide data back to the controller using LAN interface (does not include A/D conversion time). 2