STAIRCASE LIGHTING TIMER ASN-01 INSTRUCTION MANUAL Zakad Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. odziska ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamel.pl, e-mail: marketing zamel.pl DESCRIPTION TECHNICAL PARAMETERS ASN - 01 The staircase lighting time delay switch ASN-01 is used to control lighting Input (supply) terminals: L, N devices on staircases and corridors. After Input rated voltage: 230 V~ releasing the system it switches on the Input voltage tolerance: from -15 to +10% lighting for the preset time by the user. Nominal frequency: 50 / 60 Hz After that it switches off automatically. Rated power consumption: 48 mA The operating time can be adjusted from Supply/release terminals: P / P (connected inside the device) 10 sec to 10 min by means of the poten- Power/relay supply indicator: dioda LED czerwona tiometer placed on the front panel of the Time adjustment range: from 10 sec to 10 min device. The staircase lighting time delay switch ASN-01 can be used as standard Time accuracy adjustment: 10 % time delay relay. The surface mounting Time repeatability adjustment: 5 % enables flat surfaces mounting. Time adjustment: rotational potentiometer Output relay parameters: 16 A / 250 V AC1 4000 VA Number of terminal clamps: 4 2 FEATURES Section of connecting cables: from 0,2 to 2,50 mm o Ambient temperature range: from -20 to +45 C Staircase lighting control, Operating position: free operating time adjustment from 10 Mounting: 2 x stretcher 5x(3x30) sec to 10 min, Protection degree: IP20 (PN-EN 60529) power supply indicator red LED Protective class: II diode, Overvoltage category: II cooperation with monostable pushbuttons equipped with illumina- Pollution degree: 2 tion lamps, Rated impulse withstand voltage: 1 kV (PN-EN 61000-4-5) cooperation with 3-wire or 4-wire Dimensions (height / width / depth): 69x56x27 mm installation, Weight: 76 g surface mounted casing, Reference standards: PN-EN 60669-1 voltage relay output max 16 A capa- PN-EN 60669-2-1 PN-EN 61000-4-2,3,4,5,6,11 city. The device is designed APPEARANCE for one-phase installa- tion and must be instal- Power/relay supply indicator led in accordance with standards valid in a par- ticular country. The devi- CAUTION ce should be connected Time adjustment according to the details included in this operating manual. Instal- lation, connection and control should be carried out by a qualified electrician staff, who act in accordance with the service manual and the device functions. Disas- sembling of the device is equal with a loss of guarantee and can cause electric shock. Before installation make sure the connection cables are not under voltage. The cruciform head screwdriver 3,5 mm should be used to instal the device. Im- proper transport, storage, and use of the device influence its wrong functioning. Release terminal (P) It is not advisable to instal the device in Output (load) supply terminal (P) the following cases: if any device part is Power supply terminal (L, N) missing or the device is damaged or de- formed. In case of improper functioning of the device contact the producer. ver. 0.4.3 2006.06.20 11:00MOUNTING CONNECTING 1. Disconnect the power supply from the mains by the phase fuse, the circuit-breaker or the switch-di- sconnector that are joined to the proper circuit, 2. Check if there is no voltage on connection cables by means of a special measure equipment, 3. Fasten the ASN-01 to the base with the screw, 4. Connect the cables with the ter- minals according to installing dia- gram, 5. Switch on the power supply from the mains, 6. Adjust the demanded switch on 4 wire system 3 wire system time by means of a potentiometer. FUNCTIONING EXAMPLE OF INSTALLATION After proper mounting and installa- tion the device is ready to work. Rele- asing the system with the monostab- le pushbutton causes the lighting to switch on for the preset time. After the preset time is over the lighting is auto- matically switched off till its another re- lease. The staircase lighting time delay switch cooperates with 3-wire or 4-wire system. While mounting the device pay attention the release and load systems are properly connected, otherwise the device can be irreparably damaged. Because of no anti-blocking system the light is constantly switched on in cases the pushbutton is blocked. INNER DIAGRAM Typical application: The staircase lighting time delay switch ASN-01 operating the staircase lighting works in 3-wire installation. Monostable pushbutton (equipped with illumination) can be joined parallely. DIMENSIONS TIME COURSE PRODUCT FAMILY The staircase lighting time delay switch ASN-01 belongs to staircase lighting time t delay switches ASx family. t ASx - xx (/24V) t t t Version 24 V AC/DC Wersja urzdzenia: 01 - 3, 4 wire installation 02 - anti-lock system 10 - dimmer function (double RELAY CAPACITY modular casing) Type of casing: 2000 W M - monomodular 1000 W N - surface mounting H - hermetical 500 W 750 W Symbol ver. 0.4.3 2006.06.20 11:00