PBM-04/U BI-STABLE VOLT FREE RELAY SERVICE MANUAL Zakad Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. odziska ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing zamel.pl DESCRIPTION TECHNICAL DATA PBM-04/U bi-stable relay is used to PBM-04/U control lighting or any other device with Tripping terminal: IN the help of unipolar parallel connected switches. Another push of any switch Tripping terminals for illuminated switches: IN, IN causes actuation or disengagement of Tripping rated voltage: 12 230 V AC/DC devices connected to output terminals Supply voltage tolerance: -15 +10 % (change in relay status). The device Rated frequency: 50 / 60 Hz enables to use typical unipolar switches Rated power consumption: 0 mA connected to IN inlet and switches with illumination connected to IN inlets (trip- Rated triggering power consumption: 11 mA ping only from L line for 230V voltage). Relay contact parameters: 1NO - 10 A / 250 V AC1 2500 VA Structure of the relay enables to record Number of terminals: 7 the current status in case of loss of sup- 2 Section of wire conductors: 0,2 2,50 mm ply voltage. Zero power consumption o Operating temperature: -20 +45 C stands as an important feature of the device. Operating position: optional Fixing of the casing: TH35 rail (in accordance with PN-EN 60715) Protection degree of casing: IP20 (PN-EN 60529) FEATURES Protection class: II Overvoltage category: II Degree of pollution: 2 Bi-stable (biconditional) lighting con- trol, Surge voltage: 1 kV (PN-EN 61000-4-5) universal scope of 12 230 V AC/DC Dimensions: single module (17,5 mm) 90x17,5x66 mm supply voltage, Weight: 0,065 kg zero power consumption, Compliance with the following standards: PN-EN 60669-1 memory of relay status, PN-EN 60669-2-1 cooperation with numerous unipolar PN-EN 61000-4-2,3,4,5,6,11 switches, also the ones with illumina- tion, two wire control installation, relay output one short circuiting con- APPEARANCE tact with maximal capacity of 10 A. Tripping terminal (IN) Power supply terminal (A2) This device must be in- stalled in one-phase sup- ply network, according to legally binding regulations Tripping terminals (IN) and standards. Installation must be carried out accor- NOTE ding to this instruction ma- nual. Procedures such as: installation, connection and adjustment of the device should be carried out by qualified electricians who are familiarised with this in- struction manual and device functions. If the casing is dismantled, the warranty expires and there is the danger of an electric shock. Before installation, make sure that voltage is not present on the conductors. Use cross screwdriver with diameter of 3.5 mm, for in- stallation. Transport, storage and use of this device influence its correct operation. Instal - lation of this device is not recommended in the following situations: lack of parts, dama- ge or deformations of the device. In the case of incorrect functioning of the device, please contact the manufacturer. The symbol showing a selective collection of electric and electronic equipment. Relay output Used up equipment must not be placed together with another kind terminals (11, 11, 14) of waste. VER. 001 04.08.2010MOUNTING, FUNCTIONING CONNECTION 1. Disconnect supply circuit by means of Compatibility with unipolar switches without backlight fuse, overcurrent protection device or (voltage: 12 230 V AC/DC) switch disconnector connected to ap- L(+) propriate circuit. N(-) 2. Check the voltage free status on supply connectors using an appro- priate tester. 3. Install PBM04/U device in switching station on TH-35 transfer busbar 4. Connect leads to the connecting ter- minals according to the electrical dia- gram. 5. Switch on the supply circuit. The device if ready to operate after proper connection. Proper operation of the relay may be verified by pushing the release switch several times the device should engage and disengage the load Compatibility with unipolar switches with backlight connected to its output terminals. IN (only for 230 V AC voltage) control inputs are inlets aimed to be com- L patible with illuminated switches supplied N with 230 V AC voltage. IN input is a uni- versal control input for switches supplied with 12230 V AC/DC voltage. TIME COURSES IN IN t t FAMILY OF PRODUCTS DIMENSIONS CAPACITY PBM-04/U bi-stable relay belongs to PBM bi- 1250 W 600 W stable relays 300 W 450 W Supply version: 24V - 24V AC/DC available for PBM-01, PBM-02, PBM-03, 12-24V- 1224V AC/DC available for PBM-05 NTERNAL SCHEME U - universal supply voltage 12230V AC/DC Version of the device: A2 01 - basic 02 - extended with SET and RESET functions, as well as status memory 03 - with time limit function 14 04 - volt-free with status memory 05 - volt-free with SET and RESET IN 11 T functions, as well as status memory Type of casing: 11 M module IN P cable box Symbol of the device WARRANTY CARD There is 24 months guarantee on the product 1. ZMIE ZAMEL SP. J. assures 24 months guarantee for the product. 2. The manufacturers guarantee does not cover any of the following actions: a) mechanical damage during transport, loading / unloading or under other circumstances, b) damage caused by incorrect product mounting or misuse, c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices needed for the product functioning, d) damage caused by Act of God or any other incidents independent of the manufacturer. 3. The PURCHASER shall lay any claims in writing to the dealer or ZMIE ZAMEL SP. J. 4. ZMIE ZAMEL SP. J. is liable for processing any claim according to current Polish legislation. 5. ZMIE ZAMEL SP. J. shall process the claim at its own discretion: product repair, replacement or money return. 6. The manufacturers guarantee is valid in the Republic of Poland. 7. The PURCHASERs statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or otherwise are not affected by this warranty. Salesman stamp and signature, date of sale VER. 001 04.08.2010