2-CHANNEL RADIO MODULAR RECEIVER ROM-10 CoNNECTIoN MouNTING MANUAL INSTRUCTION 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch- disconnector combined to the proper circuit. 2. Check if there is no voltage on connection cables by means of ZAMEL Sp. z o.o. a special measure equipment. 3. Connect the cables with the terminals in accordance with the installing diagram. 4. mount ROM-10 device on a TH-35 rail. ul. Zielona 27, 43-200 Pszczyna, Poland tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 5. Switch on the power supply from www.zamelcet.com, e-mail: marketing zamel.pl the mains. TECHNICAL DATA DESCRIPTIoN CAPACITY ROM-10 2-channel radio modular receiver ROM- 10 can be mounted in distribution boards on Input (supply) terminals: L, N 1000W 500W the TH-35 rail and can realise radio control Input rated voltage: 230V AC functions using any of EXTA FREE system Input voltage tolerance: -15 +10 % transmitters. Any electric system realising 250W 375W Nominal frequency: 50 / 60 Hz radio system functions can be connected to the device relay output (e.g. wired devices of Nominal power consumption: 0,55 W EXTA home automation, relay-contactor sys- Optic signalling of power supply: LED green diode APPLICATIoN tems and others). Number of operation modes: 5 Number of channels: 2 Transmission: radio 868,32 MHz Radio modular receiver Coding way: unidirectional ROM-10 operates as Coding: addressing transmission a receiver of P-257/4 FEATuRES 4-channel remote control Maximum number of remote controls: 32 (control of lighting Range: up to 300 m in the open area cooperation with wireless EXTA FREE operation in front of Time adjustment: 1 sec. 18 hours (every second) and inside the garage). system transmitters, Optic signalling of relay status: 2 x LED red diode Additionally P-257/4 2-channel radio receiver mounted on 2 x LED red diode 12, 11, 14, 24, 21, 22 remote control can a TH-35 rail in a distribution board, control operation of ROB- Relay contact parameters: 2NO/NC 8A / 250V~ AC1 2000 VA five operation modes: switching on mode, 01/12-24V radio gate o Ambient temperature range: -10 +55 C switching off, monostable, bistable, time, controller. 2 Section of connecting cables: do 2,5 mm two output relays 8A (changeover Operating position: free contacts), Casing mounting: TH-35 rail (according to EN 60715) wide range of operation (up to 300 m), Casing protection degree: IP20 (EN 60529) power supply and relay operation are opti- Protection level: II cally signalled, Overvoltage category: II integration possibility with wired control Pollution degree: 2 systems (e.g. exta home automation), Surge voltage: 1 kV (EN 61000-4-5) connection possibility of ANT-01 antenna Dimensions: monomodular casing (17,5 mm) 90 x 17,5 x 66 mm mounted not in the distribution board, Weight: 0,087 kg possibility of widening operation range by Reference standard: EN 60669, EN 60950, EN 61000 means of RTN-01 retransmitter. APPEARANCE The device is designed for single-phase installation and must be installed in accord- ance with standards valid in Input (supply) terminals (L, N) a particular country. The device should be connected according CAuTIoN to the details included in this The ZAMEL company devices Antenna operating manual. Installation, connection and which are characterised with control should be carried out by a qualified electri - this sign can cooperate with cian staff, who act in accordance with the service each other. Optic signalling of input voltage manual and the device functions. In case of casing dismantling an electric shock Optic signalling of relay 1 status (channel 1) may occur, and the guarantee is lost then. Before Optic signalling of relay 2 status (channel 2) installation make sure the connection cables are WARRANTY CARD Antennas socket not under voltage. The cruciform head screwdriver 3,5 mm should be used to instal the device. Im- Programming push-buttons (PROG 1, PROG 2) There is 24 months guarantee on the product proper transport, storage, and use of the device 1. ZAMEL provides a two-year warranty for its products. influence its wrong functioning. It is not advisable 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances to instal the device in the following cases: if any b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- device part is missing or the device is damaged TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting or deformed. In case of improper functioning from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear) of the device contact the producer. 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. The symbol means selective 4. ZAMEL will review complaints in accordance with existing regulations. collecting of electrical and electronic 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. Relay output terminals (12, 11, 14, 24, 21, 22) 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. between the goods and the contract. It is forbidden to put the used equipment together with other waste. Salesman stamp and signature, date of sale VER. 003 20.05.2011oPERATIoN RADIo TRANSMITTERS PRoGRAMMING - CHANNEL 2 The device can operate in five modes for both channels: MoNoSTABLE BISTABLE SWITCH oN TIME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ters push-button. status cyclically always button. adjusted time (tp), after pressing the same push- SWITCH oFF but it may be switched off before button. the device switches off adjusted time finishes. Default Choose one of ROM-10 operation modes and programme the device in an analogous way as for channel 1, after pressing the push- settings - 15 seconds. but press PROG 2 push-button and watch LED diode for channel 2. button. CAuTIoN Adjusted time can- not be deleted. TIME PRoGRAMMING - CHANNEL 1 1s 2s ns Press PROG 1 push-button of ROM-10 device for a longer time Press PROG 1 push-button of ROM-10 After the adjusted time is RADIo TRANSMITTERS PRoGRAMMING - CHANNEL 1 till LED red diode switches on (constant signal). Next release device and then release it. LED red diode finished (the number of LED PROG 1 push-button. Wait (for about 5 seconds) till LED red diode switches off and then switches on red diode flashes) press MoNoSTABLE mode: switches on (first signal pulsates, next the signal is constant). (signal pulsates). Every LED diode pulse PROG 1 push-button and equals 1 second. then release it - TIME IS ADDED. Time programming for channel 2 - programme the device in an analogous way as for channel 1, but press PROG 2 push-button and watch LED diode for channel 2. Maximum time is 18 hours. Press transmitters Press PROG 1 push-button of ROM-10 device Release transmitters Press the same transmitters push-button for for a longer time until LED red diode switches on push-button. LED red diode push-button and release it. LED red a longer time. (constant signal). Next release PROG 1 push-button. switches on (first signal diode switches on (the signal pulsa- RADIo TRANSMITTERS DELETIoN pulsates, next the signal tes) and next it switches off - THE is constant). TRANSMITTER IS ADDED. BISTABLE mode: After 5 seconds LED red diode switches on Press PROG 1 push-button of ROM-10 Release the push-button in ROM-10 Press PROG 1 push-button of ROM-10 device Press the transmitters push-button Release transmitters push-button. LED (signal pulsates) and then it switches off. device for a longer time. - MEMORY IS DELETED. for a longer time until LED red diode switches on for a longer time. LED red diode switches on red diode switches on (the signal pulsates), (constant signal). Next release PROG 1 push-button. (first signal pulsates, next the signal is constant). next the LED red diode switches off - it CAuTIoN: This procedure causes transmitters deletion from the memory of channel 1 and channel 2. means the TRANSMITTER IS ADDED. SWITCH oN/SWITCH oFF mode (two push-buttons): CooPERATIoN AND oPERATING RANGE Symbol: RoP-01 RoP-02 RoB-01 SRP-02 SRP-03 RWG-01 RWL-01 RoM-01 RoM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press PROG 1 push-button of ROM-10 device Press and release transmitters first Press and release the second transmitters P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m for a longer time until LED red diode switches on push-button. LED red diode switches on push-button. LED red diode switches on P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m (constant signal). Next release PROG 1 push-button. (first signal pulsates, (the signal pulsates) and next it switches next the signal is constant). off - THE TRANSMITTER IS ADDED. RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m TIME mode (one push-button): RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m Press PROG 1 push-button of ROM-10 device Press PROG push-button of ROM-10 Press and release the same transmitters RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m for a longer time till LED red diode switches on device and then release it. LED red diode push-button. LED red diode switches on RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m (constant signal). Next release PROG 1 push-button. switches on (first signal pulsates, (signal pulsates) and then switches off - next the signal is constant). THE TRANSMITTER IS ADDED. * - 1-channel transmitters do not cooperate with roller blind controllers. An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE transmitters CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter is analogous. and a receiver, it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, CAuTIoN: Every transmitter can cooperate with RoM-10 in a different mode, depending on how they were added to the device. metal: from 90 to 100% , glass: from 10 to 20 %, over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative influence on the range. one transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. VER. 003 20.05.2011