1-CHANNEL RADIO RECEIVER ROP-01 CONNECTION MOUNTING MANUAL INSTRUCTION 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector combined to the proper circuit. 2. Check if there is no voltage on connection cables by means of ZAMEL Sp. z o.o. a special measure equipment. 3. Connect the cables with the termi- nals in accordance with the install- ing diagram. ul. Zielona 27, 43-200 Pszczyna, Poland 4. Install ROP-01 device in installa- tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 tion cable box. www.zamelcet.com, e-mail: marketing zamel.pl 5. Switch on the power supply from the mains. DESCRIPTION TECHNICAL DATA CAPACITY Radio receivers are used both as el- ROP-01 ements in mounting in flush and surface Input (supply) terminals: L, N 750W 500W installation cable boxes and as an ac- Input rated voltage: 230 V AC tuator built directly in lighting fittings and Input voltage tolerance: -15 +10 % other receivers. ROP-01 enables opera- 250W 375W Nominal frequency: 50 / 60 Hz tion in 5 different modes (switching on, switching off, monostable mode, bistable Nominal power consumption: 0,29 W mode, time mode.) Number of operation modes: 5 APPLICATION Number of channels: 1 Transmission: radio 868,32 MHz Transmission way: unidirectional 1-channel radio receiver Coding: addressing transmission FEATURES ROP-01 operates as a receiv- Maximum number of transmitters: 32 er of 8-channel remote con- Range: up to 230 m in the open air cooperation with wireless EXTA FREE troller P-256/8 and of 2-chan- Time adjustment: 1 second 18 hours (every second) control system transmitters, nel button radio transmitter Optical signalling of transmitters operation: red LED diode 1 NO/OC output relay (dry contacts), lighting, heating operation control, RNK-02 (light sources switch Relay output clamps: 12, 11, 14 easy junction box 60 mm installation, Relay contacts parameters: 1NO/NC 5A / 250V~ AC1 1250 VA on/switch off control). 5 operation modes: switching on, swit- Number of terminal clamps: 5 The above mentioned trans- ching off, monostable mode, bistable 2 Section of connecting cables: up to 2,5 mm mitters can also control op- mode, time mode (switch off delay), o Ambient temperature range: -10 +55 C eration of radio lighting switch wide operation range (up to 230 m), Operating position: free operation is optically signalled, RWL-01 and remote control low current consumption, possibility of Casing mounting: junction box 60 mm socket RWG-01. constant operation, Casing protection degree: IP20 (EN 60529) possibility of increasing operation ran- Protection level: II ge by means of RTN-01 retransmitter. Overvoltage category: II Pollution degree: 2 Surge voltage: 1 kV (EN 61000-4-5) Dimensions: 47,5 x 47,5 x 20 mm Weight: 0,043 kg Reference standard: EN 60669, EN 60950, EN 61000 The device is designed for single-phase installation and APPEARANCE must be installed in accord- ance with standards valid in a particular country. The de- vice should be connected Relay output terminals CAUTION according to the details in- cluded in this operating manual. Installation, (12, 11, 14) connection and control should be carried out by a qualified electrician staff, who act in accord - The ZAMEL company devices which ance with the service manual and the device are characterised with this sign can functions. Disassembling of the device is equal Input (supply) terminals (L, N) cooperate with each other. with a loss of guarantee and can cause elec- tric shock. Before installation make sure the connection cables are not under voltage. The cruciform head screwdriver 3,5 mm should be WARRANTY CARD used to instal the device. Improper transport, storage, and use of the device influence its Optical signalling of receivers operation There is 24 months guarantee on the product wrong functioning. It is not advisable to instal 1. ZAMEL provides a two-year warranty for its products. the device in the following cases: if any device Programming buttons 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances part is missing or the device is damaged or de- b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- formed. In case of improper functioning of the TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting device contact the producer. from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear) 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. The symbol means selective 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. collecting of electrical and electronic 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. It is forbidden to put between the goods and the contract. the used equipment together with other waste. Salesman stamp and signature, date of sale VER. 005 20.05.2011OPERATION TIME PROGRAMMING The device can operate in five modes: 1s 2s ns MONOSTABLE BISTABLE SWITCH ON TIME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ters push-button. status cyclically always -button. adjusted time (tp), after pressing the same push- but it may be switched off before -button. SWITCH OFF adjusted time finishes. Default Press PROG push-button of ROP-01 device for a longer time till Press PROG push-button of ROP-01 device After the adjusted time is the device switches off settings - 15 seconds. LED red diode switches on (constant signal). Next release PROG and then release it. LED red diode switches finished (the number of LED after pressing the push- push-button. Wait (for about 5 seconds) till LED red diode switches off and then switches on (signal pulsates). red diode flashes) press -button. CAUTION Adjusted time can on (first signal pulsates, next the signal is constant). Every LED diode pulse equals 1 second. PROG push-button and then not be deleted. release it - TIME IS ADDED. Maximum time is 18 hours. RADIO TRANSMITTERS DELETION RADIO TRANSMITTERS PROGRAMMING Press PROG push-button of ROP-01 device After 5 seconds LED red diode switches on Release the push-button in ROP-01 - for a longer time. (signal pulsates) and then it switches off. MEMORY IS DELETED. MONOSTABLE mode: COOPERATION AND OPERATION RANGE Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press transmitters Press PROG push-button of ROP-01 device Release transmitters RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press the same transmitters push- push-button for for a longer time until LED red diode switches on push-button. LED red diode -button and release it. LED red dio- P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m a longer time. (constant signal). Next release PROG push-button. switches on (first signal de switches on (the signal pulsates) P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m pulsates, next the signal is and next it switches off - RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m constant). THE TRANSMITTER IS ADDED. BISTABLE mode: RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m Press PROG push-button of ROP-01 device Press the transmitters push-button Release transmitters push-button. * - 1-channel transmitters do not cooperate with roller blinds controllers. for a longer time until LED red diode switches on for a longer time. LED red diode switches LED red diode switches on (the CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, (constant signal). Next release PROG push-button. on (first signal pulsates, next the signal is signal pulsates), next the LED red it is advisable to decrease the range according to: wood and plaster - from 5 to 20, bricks - from 10 to 40%, reinforced concrete - from 40 to 80 %, metal - from 90 to 100% , constant). glass - from 10 to 20%. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have diode switches off - it means the also a negative influence on the range. TRANSMITTER IS ADDED. SWITCH ON/SWITCH OFF mode (two push-buttons): TRANSMITTERS RECEIVERS RNK-02 RNL-01 ROP-01 RWL-01 2channel button Radio 1-channel Radio lighting radio transmitter foot transmitter radio receiver switch RNK-04 RTI-01 ROP-02 RWG-01 4-channel button IR/EXTA FREE 2-channel Remote control radio transmitter transceiver radio receiver socket Press PROG push-button of ROP-01 device Press and release transmitters push- Press and release the same transmitters for a longer time until LED red diode switches on button. LED red diode switches on push-button. LED red diode switches on P-256/8 RNM-10 RDP-01 SRP-02 (constant signal). Next release PROG push-button. (first signal pulsates, next the signal is (the signal pulsates) and next it switches 8-channel 4-channel radio 1-channel Radio roller blinds constant). off - THE TRANSMITTER IS ADDED. remote controller modular transmitter radio dimmer controller TIME mode (one push-button) P-257/4 RNP-01 ROB-01/12-24V SRP-03 4-channel 4-channel Radio Central radio roller remote controller radio transmitter gate controller blinds controller P-257/2 RNP-02 ROM-01 ROM-10 2-channel 4-channel 1-channel radio 2-channel remote controller radio transmitter modular receiver radio modular receiver RCR-01 RXM-01 Press PROG push-button of ROP-01 device Press and release transmitters push- Press and release the same transmitters Radio Translator for a longer time till LED red diode switches on button. LED red diode switches on push-button. LED red diode motion sensor RS-485/EXTA FREE (constant signal). Next release PROG push-button. (the signal pulsates, next the signal is switches on (the signal pulsates) constant). and next it switches off - ACCESSORIES THE TRANSMITTER IS ADDED. An exemplary programming procedure with the use of P-257/2 remote controller. ANT-01 RTN-01 The procedure for the rest of radio EXTA FREE transmitters is analogous. External antenna Retransmitter CAUTION: Every transmitter can cooperate with ROP-01 in a different mode, depending on how they were added to the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. VER. 005 20.05.2011