Product Information

RZB-03

RZB-03 electronic component of Zamel

Datasheet
Wireless control set; EXTA FREE; IP20; -10÷55°C; 868.32MHz

Manufacturer: Zamel
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 48.0108 ea
Line Total: USD 48.01

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
     
Manufacturer
Product Category
Series
Kit Contents
Ip Rating
Type Of Module
Operating Temperature
Frequency
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
SDM-10 electronic component of Zamel SDM-10

Timer; Range:1 year; 230VAC; DIN; IP20; 14VA; 90x35x66mm; 16A
Stock : 9

SEM-01 electronic component of Zamel SEM-01

Converter: signal separator; DIN; IP20; 90x17.5x66mm; -20÷45°C
Stock : 6

SOH-01 electronic component of Zamel SOH-01

Probe light; Works with: WZM-01,WZM-02,WZN-01; 1m
Stock : 19

RZB-04 electronic component of Zamel RZB-04

Wireless control set; EXTA FREE; IP20; -10÷55°C; 868.32MHz
Stock : 0

RZB-05 electronic component of Zamel RZB-05

Wireless control set; EXTA FREE; IP20; -10÷55°C; 868.32MHz
Stock : 0

SLW-01 electronic component of Zamel SLW-01

RGB controller; SUPLA; IP20; 12÷24VDC; canned; -10÷55°C; OUT1:2A
Stock : 4

SBW-01 electronic component of Zamel SBW-01

Gate controller; SUPLA; IP20; 24VAC; 24VDC; flush mount; -20÷55°C
Stock : 3

SBW-02 electronic component of Zamel SBW-02

Gate controller; SUPLA; IP20; 12÷24VAC; 12÷24VDC; flush mount
Stock : 5

SDM-10/U electronic component of Zamel SDM-10/U

Timer; Range:1 year; 24÷250VAC; 30÷300VDC; DIN; IP20; 14VA; 16A
Stock : 0

SLW-02 electronic component of Zamel SLW-02

LED controller; SUPLA; IP20; 12÷24VDC; flush mount; -10÷55°C; IN:1
Stock : 0

Image Description
LB1930MGEVB electronic component of ON Semiconductor LB1930MGEVB

LB1930M Motor Controller/Driver Power Management Evaluation Board
Stock : 0

S1F76640M0C0 electronic component of Epson S1F76640M0C0

Switching Voltage Regulators DC to DC converter voltage regulator
Stock : 145

S6SAP412A78SA1001 electronic component of Infineon S6SAP412A78SA1001

S6AP412A - DC/DC, Step Up or Down 3, Non-Isolated Outputs Evaluation Board
Stock : 1

28820 electronic component of Parallax 28820

Power Management IC Development Tools Dual Motor Driver MC33926
Stock : 221

2927 electronic component of Adafruit 2927

Power Management IC Development Tools DC Motor + Stepper FeatherWing Add-on For All Feather Boards
Stock : 60

2928 electronic component of Adafruit 2928

Power Management IC Development Tools 8-Channel PWM or Servo FeatherWing Add-on For All Feather Boards
Stock : 6

SCO-811 electronic component of F&F SCO-811

Dimmer; 230VAC; DIN; 1.5A; -25÷50°C; 350W; Leads: screw terminals
Stock : 4

SCO-814 electronic component of F&F SCO-814

Dimmer; 230VAC; DIN; 4.5A; -25÷50°C; 1kW; Leads: screw terminals
Stock : 2

2MTR-DYNO electronic component of Texas Instruments 2MTR-DYNO

Power Management IC Development Tools 2MTR-DYNO KIT
Stock : 0

LM10010EVM/NOPB electronic component of Texas Instruments LM10010EVM/NOPB

Power Management IC Development Tools LM10010 EVAL MOD
Stock : 0

RZB-03 WIRELESS CONTROL SET CoNNECtioN SRP-02 MouNtiNG ROLLER BLINDS CONTROL MANUAL INSTRUCTION 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector LOCAL LOCAL combined to the proper circuit. 2. Check if there is no voltage on connec- tion cables by means of a special measure equipment. ZAMEL Sp. z o.o. 3. Connect the cables with the terminals in ac- cordance with the installing diagram. 4. Install SRP-02 device in installation cable box. ul. Zielona 27, 43-200 Pszczyna, Poland 5. Switch on the power supply from the mains. tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing zamel.pl RNK-02 FuNCtioNiNG, MouNtiNG DESCRiPtioN tECHNiCAL DA t A By pressing the button, the transmitter sends a RNK-02 SRP-02 SRP-02 controller is used to control signal with 868,32 MHz frequency which controls roller blind drives with 230V AC motor with Input (supply) terminals: - L, N EXTA FREE receivers. Device programming a limit switch. The device realises roller CAutioN: Input rated voltage: 3 V DC (CR2032 battery) 230 V AC procedure (adding a transmitter to a receiv- blinds local and central control functions Local switches connection (LoCAL) is optional. ers memory) is described in particular EXt A Battery life: 3 5 years - and it has the possibility of comfort mode FREE manual instructions. The device range Input voltage tolerance: - +10 -15 % adjustment. Comfort modes are used to (up to 250 m depending on a receiver) can be in- Nominal frequency: - 50 / 60 Hz adjust roller blinds position (height level) APPLiCAtioN creased by means of a retransmitter or few RTN- and to memorise the height level. Central Nominal power consumption: - 0,4 W (stand-by mode) / 0,7 W (roller blind movement) 01 retransmitters. The device can be mounted in mode is used in case of a totally closed Transmission: radio 868,32 MHz any place by means of double-sided adhesive or opened roller blind or a group of roller Coding way: unidirectional tape or two wall plugs (5x(3x30) mm. blinds with different position level. Coding: addressing transmission Maximum number of remote controls: - 32 Mounting by means of wall plugs: 1. Remove the button - to do it press the button Range: up to 250 m in the open area on one side, and on the other side put a screw- Maximum movement time of roller blind: - 120 sec driver into a slot and lift up the button. Maximum time of roller blind movement: - 1 120 sec (every 0,1 sec) 2. Find a place on the wall to mount the transmit- Optic signalling of transmitters operation: LED red diode ter, make two holes corresponding mounting FEAtuRES Local control terminals: - LOCAL (up), (down) holes from the transmitters base. Motor power supply terminals: - (up), (down) 3. Set wall plugs in the holes. Complete set of wireless control Relay contact parameters: - 2NO 5A/250V AC AC3 1250 VA 4. Fix the base by means of screwing screws into (2channel button radio transmitter RNK-02 and radio roller blinds controller Number of terminal clamps: - 6 wall plugs. 2 SRP-02), 5. Place the button again. Section of connecting cables: - up to 2,5 mm used in wired and wireless control of o Ambient temperature range: -10 +55 C roller blind, sunblind and gate drives, BAttERY CHANGE Operating position: free (electric motors of 230V AC), Battery discharge status is signalled by sev- Casing mounting: wall plugs, double-sided adhesive tape installation cable box 60 mm wired local control inputs, eral LED red diode flashes during transmis- Casing protection degree: IP20 (EN 60529) easily installed in 60 mm junction box, sion time. energy-saving device, possibility of con- Protection level: III II 1. Remove the button (mounting - point 1). stant work, Overvoltage category: - II 2. By means of a screwdriver lever up the printed- two comfort modes - upper and bottom Pollution degree: 2 circuit board releasing the bottom latch and re- (memory of roller blind height level), move it from the base. Surge voltage: - 1 kV (EN 61000-4-5) possibility of cooperation with any roler 3. Remove the battery from the latch. Dimensions: 90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm blind switch (which is not equipped in 4. Mount a new battery. Watch battery polari- Weight: 0,038 kg 0,039 kg backlight elements) sation marked on the latch. Wrong battery Reference standard: ETSI EN 300 220-1 EN 60669, EN 60950, mounting may cause device damage. ETSI EN 300 220-2 EN 61000 5. Put the removed printed-circuit board back in Radio flush dimmer RNK-02 operating roller The device is designed for the base. blind controller SRP-02 (roller blind opening / single-phase installation and 6. Put back the button. APPEARANCE closing). The above mentioned transmitter can must be installed in accord- ance with standards valid in be added to any number of receivers. Local wired control terminals CAutioN: a particular country. The de- (upward movement , downward movement ) While changing the battery, it is suggested to vice should be connected ac- CAutioN cording to the details included Roller blind motor terminals press any of the buttons for about 5 seconds The ZAMEL company in this operating manual. Installation, connection (upward movement , downward movement ) before putting it into a latch. Next press trans- devices which are and control should be carried out by a qualified mission button several times to check its op- Input (supply) terminals (L, N) characterised with this sign electrician staff, who act in accordance with the can cooperate eration. if the transmitter does not work prop- service manual and the device functions. with each other. erly repeat the battery change procedure. In case of casing dismantling an electric shock may occur, and the guarantee is lost then. Before Optic signalling of receivers operation installation make sure the connection cables are Programming push-button WARRANtY CARD not under voltage. The cruciform head screwdriv- er 3,5 mm should be used to instal the device. Im- Optic signalling proper transport, storage, and use of the device There is 24 months guarantee on the product of transmitters operation influence its wrong functioning. It is not advisable 1. ZAMEL provides a two-year warranty for its products. to instal the device in the following cases: if any 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances Push-button device part is missing or the device is damaged b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting or deformed. In case of improper functioning of from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device the device contact the producer. in the moment of sale (if they appear) 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. The symbol means selective 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. collecting of electrical and electronic 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. between the goods and the contract. It is forbidden to put the used equipment together with other waste Salesman stamp and signature, date of sale VER. 003 20.05.2011SRP-02 oPERAtioN RADio tRANSMittERS DELEtioN Pressing shortly the programmed push-button in local mode (<2 sec.) or roller blind switch (optional) causes the roller blind moves. Another short pressing of the same push-button or the switch causes the roller blind stops at a required level. Pressing the push-button or the switch longer (>2 sec.) causes comfort mode activates (the roller blind moves in required direction and stops according to the adjusted time). Pressing shortly transmitters push-button (programmed in central mode) causes complete opening or closing the roller blind. Press PROG push-button of SRP-02 After 5 seconds LED red diode switches on Release the push-button in SRP-02 - RADio tRANSMittERS PRoGRAMMiNG device for a longer time. (signal pulsates) and then it switches off. MEMORY IS DELETED. LoCAL mode: CooPERA tioN AND oPERA tiNG RANGE Symbol RoP-01 RoP-02 RoB-01 SRP-02 SRP-03 RWG-01 RWL-01 RoM-01 RoM-10 RDP-01 RtN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press PROG push-button of SRP-02 device Press and release transmitters first Press and release the second P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m for a longer time until LED red diode switches on push-button (movement ). LED red transmitters push-button (constant signal). Next release PROG push-button. diode switches on (first signal pulsates, (movement ). LED red diode switches on P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m next the signal is constant). (signal pulsates) and then switches off - RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m THE TRANSMITTER IS ADDED. RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m CENtRAL mode: RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RtN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m Rti-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m Press PROG push-button of SRP-02 device Press and release transmitters first Press and release the second for a longer time until LED red diode switches on push-button (movement ...). LED red transmitters push-button (movement ...). (constant signal). Next release PROG push-button. diode switches on (first signal pulsates, LED red diode switches on (the signal * -1-channel transmitters do not cooperate with roller blind controllers. Wait (for about 5 seconds) till LED red diode switches next the signal is constant). pulsates) and next it switches off - on (first signal pulsates, next the signal is constant). THE TRANSMITTER IS ADDED. CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 %, over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative influence on the range. An exemplary programming procedure with P-257/4 remote control. The procedure for the rest of radio EXTA FREE transmitters is analogous with reservation that 2-channel transmitters can be programmed only in one mode - local or central. RANGE LoSS CoNCERNiNG RADio SiGNALS GoiNG tHRouGH oBSt ACLES CAutioN: if push-button changes are required for local and central control (in 4-channel transmitter) the programming procedure should be for two modes separately (first local control push-buttons, then central control push-buttons). In case of 2- channel transmitter the change from local control to central control should start with controllers memory deletion and only then transmitte- rs programming procedure for central mode can start. one transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. CoMFoRt MoDE tiME PRoGRAMMiNG bricks: from 10 to 40 %, wood and plaster: from 5 to 20 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100%, glass: from 10 to 20 % tRANSMittERS RECEiVERS RNK-02 RNL-01 RoP-01 RWL-01 2channel button Radio 1-channel Radio lighting radio transmitter foot transmitter radio receiver switch RNK-04 Rti-01 RoP-02 RWG-01 Open the roller Press PROG push-button of SRP-02 device for a longer time until Wait again (for about 5 seconds) till 4-channel button IR/EXTA FREE 2-channel Remote control blind completely. LED red diode switches on (constant signal). Next release PROG LED red diode switches on (first signal radio transmitter transceiver radio receiver socket push-button. Wait (for about 5 seconds) till LED red diode switches pulsates, next the signal is constant). on (first signal pulsates, next the signal is constant). P-256/8 RNM-10 RDP-01 SRP-02 8-channel 4-channel radio 1-channel Radio roller blinds remote controller modular transmitter radio dimmer controller P-257/4 RNP-01 RoB-01/12-24V SRP-03 4-channel 4-channel Radio Central radio roller remote controller radio transmitter gate controller blinds controller P-257/2 RNP-02 RoM-01 RoM-10 2-channel 4-channel 1-channel radio 2-channel remote controller radio transmitter modular receiver radio modular receiver RCR-01 RXM-01 If the roller blind is in a required Press PROG push-button of SRP-02 device, Radio Translator comfort position - press PROG push- next release PROG push-button - the roller motion sensor RS-485/EXTA FREE button and release it - the roller blind blind moves automatically. stops - ROLLER BLIND MOVEMENT ACCESSoRiES TIME IS ADDED. ANt -01 RtN-01 Time programming example for upper comfort mode. In order to programme time for bottom comfort mode, it is necessary to close the roller blind completely External antenna Retransmitter before programming procedure starts. Maximum time is 120 seconds. VER. 003 20.05.2011

Tariff Desc

8543.70.00 Other machines and apparatus Free
13 Signal processors (graphic equalisers, crossovers etc.) 91 Other Free

9027.10.00 Instruments and apparatus for physical or chemical analysis (eg, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes Free

9031.80.00 MEASURING OR CHECKING INSTRUMENTS, APPLIANCES AND MACHINES, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER; PROFILE PROJECTORS Other instruments, appliances and machines Free

9030.31.00 Oscilloscopes, spectrum analysers and other instruments and apparatus for measuring or checking electrical quantities, excluding meters of 9028; instruments and apparatus for measuring or detecting alpha, beta, gamma, x-ray, cosmic or other ionising radiations.
Other instruments and apparatus, for measuring or checking voltage, current, resistance or power Multimeters without a recording device Free

8473.30.00 Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED:
.Other 71 No Weighing less than 1kg Free

8537 BOARDS, PANELS, CONSOLES, DESKS, CABINETS AND OTHER BASES, EQUIPPED WITH TWO OR MORE APPARATUS OF 8535 OR 8536, FOR ELECTRIC CONTROL OR THE DISTRIBUTION OF ELECTRICITY, INCLUDING THOSE INCORPORATING INSTRUMENTS OR APPARATUS OF CHAPTER 90, AND NUMERICAL CONTROL APPARATUS, OTHER THAN SWITCHING APPARATUS OF 8517:
8538 PARTS SUITABLE FOR USE SOLELY OR PRINCIPALLY WITH THE APPARATUS OF 8535, 8536 OR 8537:
8538.10.10 22 For programmable controllers Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted