POWER LCC600 Data Sheet 600 Watts Conduction Cooling Total Power: 600 W of Outputs: Single Outputs: 12, 28, 36, 48 Vdc Special feaS 600 W full power at elevated temperatures Wide operating temperature range (-40 C to 85 C baseplate) Adjustable output Remote output On/Off AC OK DC OK signals 5 V standby voltage Active current share Electrical Specifications Conduction-cooled/fanless Input 2 I C / PMBus Input range U Suffix: 90 - 264 Vac (Safety rating:100 - 240 Vac) 3 4 Medical and ITE Safety 127 - 374 Vdc H Suffix: 180 - 305 Vac (Safety rating: 200 - 277 Vac) Suited for BF-type applications 4 254 - 420 Vdc Active power factor correction Frequency 47 - 63 / 440 Hz (Safety rating: 50/60 Hz) Optional IP65 variant Input fusing Internal fuse on both L and N lines (12.5 A - U suffix 7 A - H suffix) Optional 277 Vac input variant EMI/RFI FCC Class B, CISPR22/EN55022 Class B 1 1 MIL-STD-461F EMI Compliance to CE101, 102 CS101, 114, 115, 116 (with external filter ) c Inrush current 25 A peak EMI Class B Power factor 0.99 typical EN61000 Immunity 2 Harmonics Meets EN61000-3-2 Class A and Class C Input current < 10 Arms 100 Vac SY nd Hold up time 20 ms min for Main Output (230 Vac) 100% Load UL + CSA: 62368-1 2 Ed. 3 ANSI ES60601-1 Efficiency 93.3% typical 230 Vac 100% Load 28 Vdc 5 UL 8750 U Suffix: 115 A typical (< 200 A max per ANSI/ES60601-1 264 Vac 3 5 Leakage current CSA-C22.2 No. 250.13 split-phase / 60 Hz) nd TV: 62368-1 2 Ed. 387 A typical (< 500 A max per IEC60601-1 264 Vac / 50Hz) rd 3 H Suffix: 0.2 mA typical (< 3.5 mA max per ITE 62368-1 Standard) 60601-1 3 Ed. 5 EN 61347-1 -2-13 Isolation voltage U Suffix H Suffix PRI-SEC: 4,000 Vac (2X MOPP) 3,000 Vac CB Scheme: IEC 60950-1 PRI-Chassis: 1,500 Vac (1X MOPP) 2,000 Vac IEC 60601-1 SEC-Chassis: 1,500 Vac (1X MOPP) 1,500 Vac 5 IEC 61347-1 -2-13 1 Artesyn Filter PN: 700-014447-0000 (Zhongguang PN: ZGLPG-10-02M). China CCC 2 Meets Class C 50% load. 3 CE Mark U suffix have both ITE and Medical Safeties. H suffix carries ITE approval only. 4 DC input rating not part of products Safety approval. 5 LED Lighting approvals apply to all 48 V output variants. ** LCC600 tested according to the medical standard IEC 60601-1-2 4th Edition. afet ompliance tureLCC600 Data Sheet Electrical Specifications Output Output rating See Ordering Information table Standby output 5.0 Vdc 1.5 A Max Set point 0.5% Factory set point Total regulation Main Output: 2.0% Combined Line / Load / Temperature 5 Vsb: 5% Rated load 600 W maximum 600 W from -40 C to 85 C Baseplate Temp. Derate output to 28 W 95 C Baseplate Temp Minimum load 0 A For both Main and 5 Vsb Outputs Output voltage adjust range See Ordering Information table Max power limited to 600 W Output noise Main Output: 1.0% max p-p Measured with 0.1 F Ceramic and 10 F Tantalum Cap, 5 Vsb: 60 mV max p-p 20 MHz BW Remote sense Compensation up to 500 mV Pin 10: +Vout RS / Pin4: -Vout RS Overcurrent protection 105 - 130% of full load current Default is Shutdown mode with Auto-retry every 2~4 sec. Output latches after 20 sec of continuous OCP fault presence. Restart after latch possible through AC recycle, Inhibit toggle or through PMBus. Overvoltage protection 125 - 145% Vo, nom Main Output Latching / AC Recyle or Inhibit toggle required for PSU 125 - 130% 5 Vsb restart Overtemperature protection > 95 C Baseplate temperature Output Shutdown / Auto-recovery AC OK Open Collector 0.8 Vdc max / 10 mA Active low when AC is present DC OK Open Collector 0.8 Vdc max / 10 mA Active low when Main Output is within regulation Remote inhibit Contact Closure Pin 19: Open/Float = ON Close/Ground = OFF Units in parallel operation Qualified up to 5 units in parallel. Consult factory if Pin 5: IShare pin for main output only. more than 5 are required. Output dimming 0-10 Vdc external voltage Consult with productsupport.ep artesyn.com 0-100 kOhm external resistance Environmental Specifications Operating temperature range -40 C to +85 C Baseplate temperature Storage temperature -40 C to +85 C Humidity 10% to 95% Altitude 16,402 ft (Operating) / 50,000 ft (Non-Operating) Shock MIL-STD-810F 516.5 Procedure I, VI Vibration MIL-STD-810F 514.5 Cat. 4, 10 Ingress protection IP65 (for suffix -4P) MTBF (calculated) >2M Hrs, 25 C per SR-332 Issue 3 Electromagnetic immunity Designed to meet EN61000-4-3, -4, -5, -8, -11 (Level 3) EN61000-4-2 (Level 4) EN60601-1-2 and EN55024 For H suffix, Level 4 for EN61000-4-5