ARTESYN CNS650-M SERIES 650 Watt AC-DC Power Supplies Advanced Energy s Artesyn CNS650-MU series of single DATA SHEET output open-frame AC-DC power supplies are offered in 12 V, 24 V, or 48 V outputs with +15% Trim range. Each power Total Power: supply comes with a 12 V fan output and 5 V standby. All 650 Watts models feature ITE and medical safety approvals and accept a universal input of 90 - 264 Vac. Depending on operating Input Voltage: conditions, its 4 x 6 x 1.54 compact and high density 90 - 264 VU-Channe Construction delivers up to 400 watts of output of Outputs: power with free air convection cooling and up to 650 watts Single with 400 LFM of forced air. These power supplies are ideal for industrial systems as well as for medical applications. SPECIAL FEATURES SAFETY Designed for forced air and natural UL/CSA ES60601-1/C22.2 convection cooling No. 60601-1 UL/CSA 62368-1 Medical and ITE safety approvals, 2x MOPP TV EN 60601-1 PMBus interface DEMKO EN 62368-1 Active current share with OR-ing FET CB IEC 60950-1 IEC 60601-1 Dual fused IEC 62368-1 Type BF ready CCC GB4943.1/GB9254 Active Power Factor Correction, GB17625.1 61000-3-2 compliant CE LVD, RoHS Built-in Class B EMI filter ** CNS650-M tested according to the Less than 1U high medical standard IEC 60601-1-2 4th 4 x 6 U-channel construction Edition. (open-frame or end-fan variants available for 12 V) <500 mW no-load power consumption 80 PLUS certified (-ME model) Three-year warranty (consult factory 2020 Advanced Energy Industries, Inc. for extended terms)CNS650-M ELECTRICAL SPECIFICATIONS Input Input voltage ra nge 90 - 264 Vac 127 - 350 Vdc Frequency 47 - 63 Hz (360 - 440 Hz with higher leakage) Inrush current 50 Apk, cold start Leakage current <300 A (using UL test method) No load power < 500 mW Output Maximum power 650 W, forced-air cooling (750 W peak) 400 W, free-air natural convection cooling (650 W peak) Adjustment range -0% / +15% Holdup time 20 ms 400 W Fan output 12 V 1.0 A (forced air) 12 V 0.5 A (natural convection) Standby output 5 V 2.0 A (forced air) 5 V 1.0 A (natural convection) Control and Protection Serial bus interface PMBus Current share Active Remote sense 2-wire (+ and -) Remote inhibit Pull inhibit low = main & fan output OFF (5 V standby is ON) Pull inhibit high (or floating) = all outputs ON AC OK Active high when normal AC input is present (with internal 10k ohm pull up to 3.3 Vdc) DC OK Active high when main O/P is within regulation (with internal 10k ohm pull up to 3.3 Vdc) Smart fan control Monitor, control and override Overvoltage protection Latching / AC recyle or inhibit toggle required for PSU restart Overload protection Auto-recovery (Constant current mode down to 50% Vout) Overtemperature protection Auto-recovery with hysteresis ENVIRONMENTAL SPECIFICATIONS Operating temperature -20 C to +80 C (derate at 50 C), startup at -40 C Storage temperature -40 C to +85 C Operating humidity 5% to 95% (non-condensing) Non-operating humidity 5% to 95% (non-condensing) Maximum altitude 5000 m (3000 m for medical), derating may apply 2 advancedenergy.com