POWER CNS650-M Series Data Sheet 650 Watt AC-DC Power Supplies Total Power: 650 Watts Input Voltage: 90 - 264 V of Outputs: Single Special feaS Designed for forced air and natural INDUSTRIAL convection cooling Medical and ITE safety approvals, 2x MOPP Electrical Specifications PMBus interface Input Active current share with OR-ing Input voltage range 90 - 264 Vac 127 - 350 Vdc FET Dual fused Frequency 47 - 63 Hz (360 - 440 Hz with higher leakage) Type BF ready Inrush current 50 Apk, cold start Active Power Factor Correction, Leakage current <300 A (using UL test method) 61000-3-2 compliant No load power < 500 mW Built-in Class B EMI filter Output Less than 1U high Maximum power 650 W, forced-air cooling (750 W peak) 4 x 6 U-channel construction 400 W, free-air natural convection cooling (650 W peak) (open-frame or end-fan variants available for 12 V) Adjustment range -0% / +15% <500 mW no-load power Holdup time 20 ms 400 W consumption Fan output 12 V 1.0 A (forced air) 80 PLUS certified (-ME model) 12 V 0.5 A (natural convection) Three-year warranty (consult Standby output 5 V 2.0 A (forced air) factory for extended terms) 5 V 1.0 A (natural convection) Safety UL/CSA ES60601-1/C22.2 No. 60601-1 UL/CSA 62368-1 TV EN 60601-1 DEMKO EN 62368-1 CB IEC 60950-1 IEC 60601-1 IEC 62368-1 CCC GB4943.1/GB9254 GB17625.1 CE LVD, RoHS ** CNS650-M tested according to the medical standard IEC 60601-1-2 4th Edition. tureCNS650-M Series Data Sheet Electrical Specifications (continued) Control and Protection Serial bus interface PMBus Current share Active Remote sense 2-wire (+ and -) Pull inhibit low = main & fan output OFF (5 V standby is ON) Remote inhibit Pull inhibit high (or floating) = all outputs ON AC OK Active high when normal AC input is present (with internal 10k ohm pull up to 3.3 Vdc) DC OK Active high when main O/P is within regulation (with internal 10k ohm pull up to 3.3 Vdc) Smart fan control Monitor, control and override Overvoltage protection Latching / AC recyle or inhibit toggle required for PSU restart Overload protection Auto-recovery (Constant current mode down to 50% Vout) Overtemperature protection Auto-recovery with hysteresis Environmental Specifications Operating temperature -20 C to +80 C (derate at 50 C), startup at -40 C Storage temperature -40 C to +85 C Operating humidity 5% to 95% (non-condensing) Non-operating humidity 5% to 95% (non-condensing) Maximum altitude 5000 m (3000 m for medical), derating may apply Other Specifications Isolation 4000 Vac (input to output) 1500 Vac (input to PE output to PE) Line harmonics 61000-3-2, Class A ESD immunity 61000-4-2 15kV (air)/8kV (contact) Criterion A Conducted EMI Level B, CISPR 22 and FCC Part 15 Radiated EMI Level B, CISPR 22 and FCC Part 15 (with cover) Surge immunity 61000-4-5, Level 3 - Criterion A Level 4 - Criterion C Medical EMC 60601-1-2, Edition 4 (cover maybe required for some tests) MTBF > 950 KHrs, 25 C, 410 W natural convection (Telcordia, Issue 3, Method 1, Case 3) > 1.3 MHrs, 25 C, 650 W forced air