Embedded Power for Business-Critical Continuity Rev. 02.17.11 18 DS1200DC 1 of 4 DS1200DC 1200 Watts Distributed Power System Distributed Power Bulk Front-End Total Output Power: 1200 Watts 3.3 or 5.0 Vdc Stand-by Output Telco Input Range: -40 to -72 Vdc Electrical Specifications Input Special Features Input ra nge: -40 Vdc to -72 Vdc GR-1089-CORE Issue 4 compliant Inrush current: ETSI EN300 132-2 part 4.7 compliant 1U X 2U form factor Efficiency: > 85% typical at high line 50% load 3 21.71 W / in Conducted EMI: Per GR-1089-CORE Issue 4 +12 Vdc Output Radiated EMI: Per GR-1089-CORE Issue 4 +3.3 Vdc stand-by (5 V standby - option) Leakage current: 1.40 mA 240 VAC No minimum load required Hold up time: 12 ms minimum Hot plug operation Output N + 1 redundant Internal ORing fets Main DC voltage: +12 V 100 A Active current sharing Stand-By: +3.3 Vsb 6 A (5 V 4 A available) shares with DS1200 AC unit 2 Adjustment range: 5% on +12V only using I C (10 - 100% load) Regulation: +12 Vdc 5% Built-in cooling fan 3.3 or 5.0 Vsb 5% (40 mm x 28 mm) 2 Over current: +12 Vdc latches off if overcurrent lasts over 1 second, I C communication interface bus otherwise it is auto recovery (See Table 1 next page) +3.3 Vsb, 9 A PMBus compliant max (hiccup mode) EERPOM for FRU data Over voltage: +12 Vdc 13.2 - 14.4 Vdc Red/green bi-color LED status +3.3 Vsb 3.76 - 4.30 Vdc Internal fan speed control Under voltage: +12 Vdc 9 - 10.8 V (latch off) Fan Fail Tach Output Signal INTEL, SSI Std. logic timing Turn-on delay: 2 second max, 5 - 50 mS, monotonic rise INTEL, SSI Std. FRU data format Main output rise time: 5 - 50 mS, monotonic rise Full digital control Two year warranty NEBS compliant Safety UL/cUL 60950 (UL Recognized) NEMKO+ CB Report EN60950 EN60950 CE Mark China CCCEmbedded Power for Business-Critical Continuity Rev. 02.17.11 18 Logic Control DS1200DC 2 of 4 PS SEATED (A4): TTL logic LOW if power supply is seated into system connector. This is a short pin. A logic HIGH if the PSU is removed PWR GOOD (C3): Active TTL high when output is within regulation limits. AC OK (B1): A low logic level if the input voltage is within allowable limits. A TTL logic HIGH level, and a 5mS early warning signal before 12.0 V DC output loss of regulation. PS INHIBIT/PS KILL (B4): When left open power supply operation will be inhibited. When the power supply is inserted into the system, this pin will be pull low by the system and turn the power supply on only after all other power supply pins have seated. PS ON (A1): The output will be enabled when this signal is pulled low, below 0.8 V outputs disabled when pin is driven high or left open. Environmental Specifications Operating temperature: -10 to 55 C Storage temperature: -40 C to +85 C Altitude, operating: 13,000 ft Electromagnetic susceptibility / Input transients: GR-1089-CORE Issue 4 RoHS & lead-free Compliant Humidity: 20 to 90% RH, non-condensing Shock and vibration specificatons: Complies with Astec Std. Specifications, Q3205 + additional NEBS requirement MTBF (Demonstrated): 500K Hrs at full load, 40 C Ordering Information Nominal Output Set Point Total Minimum Maximum Output Ripple Model Number Over Current Stand-by Air Flow Voltage Set Point Tolerance Regulation Current Current P/P DS1200DC-3 12.0 Vdc 0.2% 5% 0 A 100 A 120 mV 118 A - 147.6 A* 3.3 V 6 A STD DS1200DC-3-001 12.0 Vdc 0.2% 5% 0 A 100 A 120 mV 118 A - 147.6 A* 3.3 V 6 A REV DS1200DC-3-002 12.0 Vdc 0.2% 5% 0 A 100 A 120 mV 118 A - 147.6 A* 5.0 V 4 A STD DS1200DC-3-004** 12.0 Vdc 0.2% 5% 0 A 100 A 120 mV 118 A - 147.6 A* 5.0 V 4 A REV *Over current latches off if overcurrent lasts over 1 seconds, otherwise it is auto recovery. **Release in April 2010 Derating may apply.