POWER DS1600SPE Data Sheet 1600 Watts Distributed Power System Front-end Bulk Power Total Output Power: 1600 W continuous at high line Wide Range Input Voltage: 90 - 264 Vac Special feaS 1600 W output power at high line High power and short form factor 1U power supply 3 High density design: 40 W/in Active power factor correction EN61000-3-2 harmonic compliance Inrush current control Electrical Specifications 80plus platinum efficiency Input N+1 or N+N redundant Input voltage range 180 to 264 Vac: 1600 W 90 to 140 Vac: 800 W Active current sharing Full digital control Frequency 47 Hz to 63 Hz PMBus compliant Efficiency 94.0% peak Compatible with Artesyns universal Max input current 10.8 Arms PMBus GUI Inrush current 55 Apk Reverse airflow option Conducted EMI Class A Two-year warranty Radiated EMI Class A Power factor > 0.9 beginning at 20% load c ITHD 10% Class A + 6 dB margin Conducted/ Leakage current 1.75 mA Radiated EMI Hold-up time 10 ms RoHS compliant SY Ordering Information UL/cUL 62368 (UL Recognized) Model Number Nominal Main Output Standby Output Airflow Direction NEMKO+ CB Report EN62368 DS1600SPE-3 12 V 133.3 A 12 V 3.5 A Standard (forward) EN62368 DS1600SPE-3-001 12 V 133.3 A 12 V 3.5 A Reverse CE Mark China CQC afet ompliance tureDS1600SPE Data Sheet Electrical Specifications Output Main DC Output MIN NOM MAX Nominal setting -0.20% 12 0.20% Total output regulation range 11.4 V 12.6 V 5 Dynamic load regulation range 11.4 V 12.6 V Output ripple 150 mVp-p 4 Output current 2 A 133.33 A Current sharing Within +/-5% of full load rating Capacitive loading 2,250 F 14,000 F Start-up from AC to output 2,300 ms Output rise time 2 ms 60 ms Standby DC Output Nominal setting -3% 12 3% Total output regulation range 11.4 V 12.6 V Dynamic load regulation range 11.4 V 12.6 V Output ripple 150 mVp-p Adjustment range N/A 4 Output current 0.1 A 3.5 A N/A Current sharing Capacitive loading 47 F 1,000 F Start-up from AC to output 20 ms 2,000 ms Output rise time 2 ms 60 ms Protections Main Output 2 Overcurrent protection 115% 150% 1 13.5 V 15.0 V Overvoltage protection Undervoltage Protection 10.5 V 11.0 V Overtemperature protection Yes Fan fault protection Yes Standby Output 3 Overcurrent Protection 120% 150% 1 Overvoltage Protection 13.5 V 15.0 V Undervoltage Protection 10.0 V 11.0 V 1 Latch mode 2 Autorecovery if the overcurrent is less than 115% and last only for <500 ms 3 Standby protection is auto-recovery 4 Minimum current for transient load response testing only. Unit is designed to operate and be within output regulation range at zero load. 5 Maximum step size of 67 A at 0.5A/s, with a beginning load of 8 A, and 3,350 F capacitance