Embedded Power for Business-Critical Continuity Rev. 10.23.12 131 LCM600 Series 1 of 6 LCM600 600 Watts Bulk Front End Total Power: 600 W of Outputs: Single Output: 12 to 60 V Optional 5.0 V standby Electrical Specifications Input Input ra nge: 85 - 264 Vac (Operating) Special Features 115/230 Vac (Nominal) Input through standard IEC connector/ TERMINAL BLOCK 600 W output power Low Cost Frequency: 47 - 440 Hz, Nominal 50/60 2.4 x 4.5 x 7.5 Input fusing: Internal 10 A fuses, both lines fused 7.41 W/cu-in Inrush current: 25 A peak, either hot or cold start Industrial/Medical safety Power factor: 0.99 typical, meets EN61000-3-2 -40 C to 70 C with derating Optional 5 V 2 A Housekeeping Harmonics: Meets IEC 1000-3-2 requirements High Efficiency: 89% typical Input current: 8 A RMS max input current, at 100 Vac Variable speed Smart Fans Hold up time: 20 ms minimum for Main O/P, at full rated load DSP controlled front end Efficiency: > 89% at full load Conformal coat option Leakage current: < 0.3 mA at 264 Vac 20% adjustment range Margin programming ON/OFF power switch: N/A O R-ing FE T Power line transient: MOV directly after the fuse Ter minal block input option Isolation: PRI-Chassis 2000 VAC Basic PRI-SEC 3000 VAC Reinforced Compliance SEC-Chassis 500 VDC EMI Class B LCM600Q Efficiency Without the 5 Vsb EN61000 Immunity 92.00 90.00 88.00 86.00 100 Vac Safety 84.00 230 Vac 82.00 UL 60950-1 508/1598/1433 80.00 60601-1 78.00 CSA 60950-1 76.00 VDE 60950-1 25 50 75 100 60601 Loading % China CCC CB Scheme Report/Cert Efficiency %Embedded Power for Business-Critical Continuity Rev. 10.23.12 131 LCM600 Series 2 of 6 Output Output rating: See table 1 85 - 264 Vac Set point: 0.5% 85 - 264 Vac Total regulation range: Combined line/load/transient when measured at output terminal Main output 2% 5 Vsb 1% Rated load: 600 W maximum Derate linear to 50% from 50 C to 70 C Minimum load: No loss of regulation Main output 0.0 A 5 Vsb 0.0 A Output noise (PARD): 1% max p-p Main output 50 mV max p-p 5 Vsb output Measured with a 0.1 F Ceramic and 10 F Tantalum Capacitor on any output, 20 MHz Output voltage overshoot: No overshoot/undershoot outside the regulation band during on or off cycle Transient response: < 300 Sec 50% load step 1 A/s Step load valid between 10% to 100% of output rating Recovery time to within 1% of set point at onset of transient Max units in parallel: Up to 10 Short circuit protection: Protected, no damage to occur Bounce mode Remote sense: Compensation up to 500 mV Output isolation: Standard per safety requirements Forced load sharing: To within 10% of all shared outputs Analog sharing control Overload protection (OCP): 105% to 125% Main output 120% to 170% 5 Vsb output Overvoltage protection (OVP): 125% to 145% 12 V output 110% to 125% 5 Vsb output Overtemp protection: 10 - 15 C above safe operating area Both PFC and output converter monitored Fan Fault Protection: For-N option only. Will shutdown output and DC OK Environmental Specifications Operating temperature: -40 C to +70 C, linear derating to 50% from 50 C to 70 C Storage temperature: -40 C to +85 C Humidity: 20 to 90%, non-condensing. Operating. Conformal coat option available Fan noise: < 45 dBA, 80% load at 30 C -N Low Noise Option <35 dBA,80% Load at 30 C Altitude: Operating - 15,000 feet Storage - 30,000 feet Shock: MIL-STD-810F 516.5, Procedure I, VI. Storage Vibration: MIL-STD-810F 514.5, Cat. 4, 10. Storage Ordering Information Current Model Nominal Output Set Point Adjustment Output Ripple Power Combined Line/ Output Number* Voltage Set Point Tolerance Range P/P Max. Load Regulation Min Max LCM600L 12 V 12 V 0.5% 9.6 - 14.4 V 0 A 52 A 120 mV 600 W 2% LCM600N 15 V 15 V 0.5% 12.0 - 19.5 V 0 A 44 A 150 mV 600 W 2% LCM600Q 24 V 24 V 0.5% 19.2 - 28.8 V 0 A 27 A 240 mV 600 W 2% LCM600U 36 V 36 V 0.5% 28.8 - 43.2 V 0 A 16.7 A 240 mV 600 W 2% LCM600W 48 V 48 V 0.5% 38.4 - 57.6 V 0 A 14 A 280 mV 600 W 2% *Note: Add -T for terminal block instead of IEC input. Add-4 For 5V, SB