Embedded Power for Business-Critical Continuity Rev. 8.17.06 LCT43-E Series 1of 3 LCT43-E Series RoHS 47 Watts Total Power: 47 Watts Input Voltage: 85 - 264 VAC 120 - 300VDC of Outputs: Triple Electrical Specifications Input Special Features Input range 85 - 264 VAC (wide range) Totally enclosed 120 - 300VDC Universal input Frequency 47-63 Hz Quick Installation Inrush current <20A peak 115VAC, <40A peak 230VAC cold start 25C Built-in EMI filter Low output ripple Input current 1A max. (RMS) 115VAC Overvoltage protection Efficiency 70% typical at full load Overload protection EMI filter FCC Class B conducted and radiated CISPR 22 Class B conducted and radiated EN55022 Class B conducted and radiated Bellcore GR-1089-core Class B conducted Safety ground leadage <3.5 mA 50/60 Hz, 264 VAC input current Output Maximum power 47W with 12CFM forced air Cross regulation 2% on output 1 5% on outputs 2, 3 Hold-up time 10ms 47W load, 100VAC input Overload protection Short circuit protection on all outputs. Case overload protect- ed 110-135% above peak rating Overvoltage protection 5.50-6.75 VDC on main output Safety VDE 0805/EN60950 21310-3336-0003 UL UL60950 E186249 CSA CSA 22.2-234 -950-95-M90 CB Certificate and report 6593 CE Mark (LVD)Embedded Power for Business-Critical Continuity Rev. 8.17.06 LCT43-E Series 2of 3 Environmental Specifications Operating temperature: 0 to 50C ambient derate each out- put as 2.5% per degree from 50 to 70C Storage temperature: -40C to +85C Temperature coefficient: .04% per C Electromagnetic designed to meet IEC1000-4 susceptibility: -2, -3, -4, -5, -6, -8, -11 Level 3 Operating non-condensing 5% to Humidity: 90% .41G from 3 to 500Hz Spectral break points of .0065 G2/Hz Vibration: at 10 Hz and 200 Hz and 5 db/octave roll off at each end, 2 hours per axis >300,000 hours at full load and MTBF demonstrated 25C ambient conditions Ordering Information Maximum Load Maximum Model Output Minimu with Load with Peak Regulati Ripple 1 2 3 Number Voltage m Load Convection 12CFM Forced Load on P/P (PARD) Cooling Air LCT43-E +5V 1.0A 4A 7A 8A +4/-2% 50mV +12V 0.1A 1A 1.2A 1.5A 5% 120mV -12V 0A 0.5A 0.5A 0.6A 5% 120mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F (tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges.