ARTESYN LPQ250 SERIES 250 Watts XXXX DATA SHEET Total Power: 250 Watts Input Voltage: 85 - 264 Vac 120 - 300 Vdc of Outputs: Quad RoHS compliant SPECIAL FEATURES Cover -C Active power factor correction Optional with fan cover -CF IEC EN61000-3-2 compliance Optional end fan cover -CEF Remote sense on main output SAFETY Power fail and remote inhibit Single wire current sharing VDE 0805/EN62368 (IEC950) Built-in EMI filter 11774-3336-1262 Adjustable floating 4th output UL UL1950 EI32002 Two supervisory outputs 5 V and 12 V CSA CSA 22.2-234 Level 5 Overvoltage protection LR53982C Overload protection NEMKO EN 62368/EMKO-TUE P95102999 (74-sec) 203 Thermal overload protection CB Certificate & report 2186 DC power good CE Mark (LVD) 120 KHz switching frequency 2020 Advanced Energy Industries, Inc.LPQ250 ELECTRICAL SPECIFICATIONS Input Input range 85 - 264 Vac 120-300 Vdc Frequency 47 - 440 Hz Inrush current 20 A max, cold start 25 C Efficiency 75% typical at full load EMI filter FCC Class B conducted and radiated CISPR 22 Class B conducted and radiated EN55022 Class B conducted and radiated VDE 0878 PT3 Class B conducted and radiated Safety ground leakage current < 0.5 mA 50/60 Hz, 264 Vac input Output Maximum power With cover: 250 W with 30 CFM forced air. (-C) (-CF) (CEF) Adjustment range 5% min. on main: 5-25 V on 4th output Standby outputs 5 V 100 mA regulated, 12 V 500 mA Hold-up time 16 ms 250 W load, 115 Vac nominal line Overload protection Short circuit protection on all outputs. Case overload protected 110-145% above peak rating Overvoltage protection 5 V output: 5.7 to 6.7 Vdc. Other models 10% to 25% above nominal output LOGIC CONTROL Power fail TTL Logic signal goes high 50-150 msec after 5 V output. It goes low at least 4 ms before loss of regulation Remote on/off Requires an external contact (N.O or N.C) to inhibit outputs DC-OK TTL logic goes high 50-150 msec after the output. It goes low when there is loss of regulation. Remote sense Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protected ENVIRONMENTAL SPECIFICATIONS Operating temperature 0 C to 50 C ambient derate each output at 2.5% per degree from 50 C to 70 C Storage temperature -40 C to +85 C Temperature coefficient 0.4% per C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5 Hz to 500 Hz, operational MTBF demonstrated > 550,000 hours at full load and 25 C ambient conditions 2 advancedenergy.com