POWER LPS170 Series Data Sheet 175 Watts Total Power: 100 - 175 Watts Input Voltage: 85 - 264 Vac 120 - 300 Vdc of Outputs: Single SPECIAL FEATURES Active power factor correction IEC EN61000-3-2 compliance Wide range adjustable output: Remote sense on main output Single wire current sharing Power fail and remote inhibit Built-in EMI filter Low output ripple Overvoltage protection Electrical Specifications Overload protection Input Thermal overload protection Input range 85 - 264 Vac 120-300 Vdc DC power good Frequency 47 - 63 Hz 5 V standby output Inrush current 38 A max, cold start 25C 12 V Aux output Efficiency 75% typical at full load Optional cover (-C suffix) EMI filter FCC Class B conducted RoHS compliant CISPR 22 Class B conducted EN55022 Class B conducted SAFETY VDE 0878 PT3 Class B conducted VDE 0805/EN60950 (IEC950) Power Factor 0.99 typical UL UL1950 Safety ground leakage current 1.0 mA 50/60 Hz, 264 Vac input CB Certificate and report Output CSA CSA 22.2-234 Level 3 Maximum power 110 W convection (75 W with cover) CE Mark (LVD) 175 W with 30 CFM forced air (130 W with cover) NEMKO EN 60950/EMKO-TUE Adjustment range 2:1 wide ratio minimum Standby outputs 5 V 2 A regulated 5% Hold-up time 20 ms 175 W load at nominal line Overload protection Short circuit protection on all outputs. Case overload protected 110-145% above peak rating Overvoltage protection 10% to 40% above nominal output Aux output 12 V 1 A -5 %, +10%LPS170 Series Data Sheet Logic Control Power failure TTL logic signal goes high 100 - 500 msec after V1 output It goes low at least 4 msec before loss of regulation Remote inhibit Requires contact closure to inhibit outputs Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. DC - OK TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation Environmental Specifications Operating temperature 0 to 50 C ambient derate each output at 2.5% per degree from 50 to 70 C Low temperature start -20 C Temperature coefficient 0.4% per C Storage temperature -40 to 85 C Electromagnetic susceptibility Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational MTBF demonstrated >550,000 hours at full load and 25 C ambient conditions Ordering Information Maximum Load Maximum Load Model Output Minimum Ripple 1 2 with Convection with 30CFM Peak Load Regulation 3 Number Voltage Load P/P(PARD) Cooling Forced Air LPS172 5 V (2.5 - 6 V) 0 A 22 A 35 A 38 A 2% 50 mV LPS173 12 V (6 - 12 V) 0 A 9.1 A 15 A 16.5 A 2% 120 mV LPS174 15 V (12 - 24 V) 0 A 7.3 A 12 A 13.2 A 2% <1% LPS175 24 V (24 - 54 V) 0 A 4.5 A 7.5 A 8.2 A 2% <1% 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25 C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 4. Remote inhibit resets OVP latch. 5. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Note: -C suffix added to the model number indicates cover option.