ARTESYN LPS200-M SERIES 250 Watts Advanced Energys Artesyn LPS200-M series medically- AT A GLANCE approved AC-DC power supplies are available with a nominal main output of 5 V, 12 V, 15 V, 24 V or 48V. Auxiliary 12 V fan Total Power: output is also provided. LPS200-M power supplies provide 125 to 250 Watts 125 watts of output power with free air convection cooling or up to 250 watts with 30 CFM of forced air. All models have a Input Voltage: power factor of 0.99 typical and a 3 x 5 x 1.32 inch form factor. 90 to 264 Vac of Outputs: Single SPECIAL FEATURES SAFETY Medical and ITE safeties TUV 62368, 60601-1 Active power factor correction UL 62368, 60601-1 3 x 5 footprint cULus 62368, 60601-1 Less than 1U high CB Certificate & report EN61000-3-2 compliant CE Mark (LVD) Remote sense Power fail Adjustable main output Built-in Class B EMI filter Overvoltage protection Overload protection Thermal overload protection Isolated 12 V Fan output LPX200 enclosure kit available RoHS compliant 2021 Advanced Energy Industries, Inc.LPS200-M ELECTRICAL SPECIFICATIONS Input Input ra nge 90 - 264 Vac 120 - 300 Vdc Frequency 47 - 63 Hz Inrush current 50 A max., cold start 25 C Efficiency 86% typical at full load EMI/RFI FCC Class B conducted CISPR22 Class B conducted EN55022 Class B conducted VDE0878PT3 Class B conducted Power factor 0.99 typical Safety ground leakage current 275 A 50/60 Hz, 264 Vac input Output Maximum power 125 W for convection (100 W for LPS202-M) 250 W (200 W for LPS202-M) with 30CFM forced air Adjustment range 10% minimum on the main outputs Fan output 12 V 0.5 A convection, 1 A forced air isolated, 10% Hold-up time 16 ms 250 W load, 120 Vac input Overload protection Short circuit protection on all outputs. Case overload protected 110 - 160% above rating Overvoltage protection 15 - 50% above nominal output Logical Control Power failure Open collector logic signal goes high 100 - 500 msec after main output it goes low at least 6 msec before loss of regulation Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. ENVIRONMENTAL SPECIFICATIONS Operating temperature 0 C to 50 C ambient derate each output as 2.5% per degree from 50 to 70 C. -20 C start up Storage temperature -40 C to +85 C Electromagnetic susceptibility Designed to meet EN61000-4 -2, -3, -4, -5, -6, -8, -11 Level 3 Humidity Operating non-condensing 10% to 95% RH Vibration IEC68-2-6 to the levels of IEC721-3-2 MTBF calculated 1 million hours at full load and 25 C ambient conditions. 230 Vac input, Bellcore 2 advancedenergy.com