POWER LPS250 Series Data Sheet 250 Watts Total Power: 250 Watts Input Voltage: 85 - 264 Vac 120 - 300 Vdc of Outputs: Single SPECIAL FEATURES Active power factor correction IEC EN6100-3-2 compliance Remote sense & remote inhibit Power fail Single wire current sharing Electrical Specifications Built-in EMI filter Input 2:1 Wide range output voltage adjust Input range 85 - 264 Vac 120 - 300 Vdc 2 Supervisory outputs 5 V and 12 V Frequency 47 - 440 Hz Overvoltage protection Inrush current 20 A max, cold start 25 C Overload protection Efficiency 75% typical at full load Thermal overload protection EMI filter FCC Class B conducted and radiated DC power good CISPR 22 Class B conducted and radiated 120 kHz switching frequency EN55022 Class B conducted and radiated VDE 0878 PT3 Class B conducted and radiated RoHS compliant Cover -C Safety ground leakage current < 0.5 mA 50/60 Hz, 264 Vac input Optional top with fan cover -CF Output Optional end fan cover -CEF Maximum power With cover: 250 W with 30 CFM forced air. (-C) (-CF) (CEF) SAFETY Supervisory output 5 V 100 mA regulated 12 V 500 mA VDE 60950 Adjustment range 2:1 wide ratio UL 60950 Hold-up time 20 ms 250 W load, 115 VAC nominal line CSA 60950 Overload protection Short circuit protection on all outputs. Case overload protected NEMKO 60950 10 - 145% above peak rating CB Certificate and report 2186 Overvoltage protection 5 V output: 5.7 to 6.7 Vdc. Other models 10% to 25% above nominal output CE Mark (LVD) Logical Control Power failure TTL Logic signal goes high 50 - 150 msec after 5 V output. It goes low at least 4 ms before loss of regulation Remote on/off Requires an external contact (N.O or N.C) to inhibit outputs DC - OK TTL logic goes high 50 - 150 msec after the output. It goes low when there is loss of regulation. Remote sense Compensates for 0.5 V lead drop minimum, will operate without remote sense connected. Reverse connection protectedLPS250 Series Data Sheet Environmental Specifications Operating temperature 0 to 50 C ambient derate each output at 2.5% per degree from 50 to 70 C Storage temperature -40 C to +85 C Temperature coefficient 0.4% per C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating non-condensing 5% to 95% Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.7 G peak 5 Hz to 500 Hz, operational MTBF demonstrated > 550,000 hours at full load and 25 C ambient conditions Ordering Information Model Output Minimum Maximum Load with Ripple 1 2 Peak Load Regulation 3 Number Voltage Load 30CFM Forced Air P/P (PARD) LPS252-C 5 V (3 - 6 V) 1.50 A 50 A 60 A 2% 50 mV LPS253-C 12 V (6 - 12 V) 0.63 A 21 A 25 A 2% 120 mV LPS254-C 15 (12 - 24 V) 0.50 A 16.7 A 20 A 2% 150 mV LPS255-C 24 V (24 - 48 V) 0.32 A 10.4 A 12.5 A 2% 240 mV 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2. At 25 C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 4. If optional CF or CEF fans are not used, 30CFM forced air cooling needs to be provided and is required through the length of the power supply. Not convection rated. 5. Output voltage adjustment requires a minimum load. 6. Remote inhibit resets OVP latch 7. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Note: -CF suffix added to the model number indicates cover with top fan. -CEF suffix added to the model number indicates cover with dual end mounted fan cover and AC inlet.